Core Design 1

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 12

CORE DESIGN

Definition Of Core
• The central of arterial part of a multistory building that
integrates functions and service needs for established
occupants. Such areas are normally composed of toilet
facilities, elevator banks, janitors’ closet, utilities, mechanical
facilities, smoke shafts and stair.

• Core also known as facade envelope is a spatial element for


load-bearing high-rise building system.
Characteristic
• Shape of core
• Number of cores
• Location of cores
• Arrangement of cores
• Geometry of building as generator of core
form
Function
• Tying the building together to act as a unit
• To maximize flexibility in layout
• As shear wall systems to provide the
necessary lateral stability for the building
• Resist lateral forces from any direction
• Carries gravity loads
Elements
• Electrical & Telephone
• Piping and risers
• Transportation
• Fans room
• Toilets
PLACEMENT
Advantages and Disadvantages
• Off Center
– Advantages
• All window or building perimeter space to be used for
offices
• More flexibility in maximum depth and arrangement of
spaces
• Affords the opportunity of developing small secluded space
in the relatively narrow portion of the floor plan where the
core is closes to the exterior walls.
– Disadvantages
• Present some problems of access
• Less flexibility of tenant distribution
• Remote and thus less convenient to the far sides and
corners of the building
CENTRAL CORE
• Central
– Advantages
• Allows all window all window space to be utilized as rental of the
building plan will permit offices of verging depths to receive natural
light
• Extremely convenient of access and in some cases may be
equidistant for all side
• Simplifies area division & provides good flexibility of tenant
distribution in the some way
• Horizontal utility runs may also relatively equidistant from the core
• Combine with a square building plan, bearing exterior & core walls,
this location permits a floor plan tree of columns and thus totally
flexible for office layout
• Disadvantages
• The central interior location limits the depth of offices in the mid-
zone of each floor
• It requires an access corridor around its perimeter
MATERIAL
• Reinforced concrete
– large net tension forces exist can negate the inherent efficiency
of concrete in compression resistance
– Walls become thick
• Concrete
– Fire-resistance, in particular of lift and piping shafts, is good
– Execution is efficient
– Lateral forces can be transmitted employing the surrounding skeleton
– sufficient stiffness
• Steel
– Large and costly
– achieve its lateral stability.
– necessary core stiffness
– relatively rapid assemblage of the prefabricated members.
– Enclose space, no extra consideration need to be given to fire proofing.
– Lack of ductility
– Respect to earth quake loading
Structure
• Cantilever floor
• Hanging floor
• Core-in-r.c frame
• Bunched hanging floors
• Bunched cantilever floors
• Composite
• Core-in-steel frame
System
• Core-in-frame
• Cantilever-core
• Composite
• Core-cable
• CONTINUE CORE 2

You might also like