Certificate – Cертификат – 證明書 – Certificate of Compliance
No. 3B170926.SZETD89
Test Report no. 17ZCTS0920002-2ATEX, 17ZCTS0920002-3ATEX, 17ZCTS0920002-4ATEX, 17ZCTS0920002-5ATEX
Certification ECM
Mark: European Type
Conformity
Approved
Certificat – 증명서 – ةداهش
related to CE Directive(s):
2014/34/EU (Equipment for Explosive Atmospheres)
II M2 G Ex demb IIC T6
II M2 D Ex tD A21 T80℃ IP66
Remark: The product(s) has been verified on a voluntary basis. The product(s) satisfies the requirements of the Certification Mark of ECM, in reference to the above listed Standard(s). The
above Compliance Mark can be affixed on the product(s) accordingly to the ECM regulation about its release and its use. The regulation can be found at www.entecerma.it. This
Certificate of Compliance can be checked for validity at www.entecerma.it
This verification doesn’t imply assessment of the production of the product(s).
We attest that a TCF for the Marking process is in place. Whereas the
Manufacturer is Responsible to start the Marking Certification Procedure through an appointed Notified Body and the perform all the necessary activities,
as required by the Directive and accepted by the Notified Body, before placing the Mark on the product(s).
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-0:2012/A11:2013
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4
II M2 D Ex tD A21 T135°C
II M2 G Ex deia IIC T4 II M2 D Ex tD BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-
21, BAT95-11
A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W
No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.
Summary of testing:
Test performed in accordance with all of the clauses of according IEC 60079-0
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.
Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.
Page 5 of 20
Page 4 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
1 SCOPE
2 NORMATIVE REFERENCES
3 TERMS AND DEFINITIONS
4 Pass
CONSTRUCTIONAL REQUIREMENTS FOR ALL
ELECTRICAL APPARATUS
4.1 General Pass
4.2 Electrical connections
4.2.1 General
Pass
The circuits of handlamp are permanent connection.
For the rechargeable battery of A-1280, the charge circuit is not working during the Pass
normal working condition.
Pass
Connections made using terminals complying with
IEC 60947-7-1, IEC 60947-7-
2, IEC 60999-1, or IEC 60999-2
Pass
The circuits of handlamp are permanent connection.
The power supply of it is battery. N/A 4.2.2.3 Field wiring connection facilities integral to Pass
“e” apparatus or components The circuits of handlamp are permanent connection.
Page 6 of 20
Page 5 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 7 of 20
Page 6 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
6.2 Mechanical strength of equipment Refer to Cl. 26.4 in test report Pass
IEC60079-0. See 26.5.1.3.
6.3 Opening times N/A
6.4 Circulating currents No circulating currents. N/A
6.5 Gasket retention 1. A rubber ring is made of Pass
silicon between lamp head and enclosure.
The rubber ring is in the groove of the
enclosure.
Page 8 of 20
Page 7 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
7.2.1 Tests for thermal endurance See clause 26.8 and 26.9 in Pass
this report.
7.2 Thermal endurance Pass
7.2.2 Material selection The COT of the sealing strip Pass
and RTI of the enclosure is 20K higher than the
maximum
operating temperature. Refer to Clause 26.5, 7.1.3 and
7.1.4.
Page 9 of 20
Page 8 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 10 of 20
Page 9 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 11 of 20
Page 10 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 12 of 20
Page 11 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 13 of 20
Page 12 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 14 of 20
Page 13 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
26.4.3 Drop test The drop test was carried out Pass
at the temperature of -15. The battery was connected to
the test sample. The position of the sample for the drop
test is the most unfavorable condition. respectively with
7J impact energy
Page 15 of 20
Page 14 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
26.5.2 Thermal shock test The test was carried out on Pass
glass plate.
The temperature of glass plate
26.5.3 Small component ignition test (G roup I and Group II) broken. N/A
The components on PCB N/A
26.5.3.1 General
comply with T4
The components on PCB N/A
26.5.3.2 Procedure
comply with T4
Shenzhen ZCT Technology Co., Ltd.
3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 16 of 20
Page 15 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
26.8 Thermal endurance to heat The samples were stored for Pass
28 days at 90% relative humidity at a temperature of
80℃.
26.9 Thermal endurance to cold The sample was stored for 24 Pass
hours at a temperature of
-20℃.
26.10 Resistance to light Tests were carried out Pass
according to the standard.
26.10.1 Test procedure Size of test bars: Pass
80mm×10mm×4mm; number of test bars: 12;
temperature
of black panel: (65 ±3)℃; exposure time:
1000h.
Page 17 of 20
Page 16 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
26.11 Resistance to chemical agents for Group I Group II and Group III N/A
electrical equipment Earth continuity
26.12 Earthing is not included. N/A
26.13 of parts of enclosures of non-metallic materials enclosure and carried out Pass
Surface resistance test of parts according to the standard. The surface resistance
is
3.0×103 The surface resistance is tested on the
parts of Ω,less than 109Ω.
Page 18 of 20
Page 17 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
28.1 28 Conformity with the documentation The manufacturer carries out Pass
MANUFACTURER'S RESPONSIBILITY the verifications or tests. The sample conforms to the
documentation.
Page 19 of 20
Page 18 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
29.3 Ex marking for explosive gas atmospheres Ex e ib IIC T4Gb For the Pass
nameplate, see cover of this report.
29.4 Ex marking for explosive dust atmospheres Ex t IIIC T130℃ Db IP66 Pass
29.5 Combined types of protection There is two protection type Pass
“d” and “e”. Protection type of the enclosure is “e”,
protection
type of circuit is “ib”.
29.7 Ga using two independent Gb types of Only one Gb protection. N/A
protection
29.6 Multiple types of protection Combined types of protection, N/A
see clause 29.5.
29.8 Ex components N/A
29.9 Small equipment and small Ex components Ex components are not N/A
included. No small equipment and small Ex
components
29.10 Extremely small equipment and extremely No extremely small equipment N/A
small Ex components and extremely small Ex components.
Page 20 of 20
Page 19 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 21 of 20
Page 20 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict
Page 22 of 20
Page 1 of 20 17ZCTS0920002-3LR
IECEx TEST REPORT EN 60079-7
Electrical equipment for explosive gas
atmospheres Part 7: Increased safety“e”
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-7:2015
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4
II M2 D Ex tD A21 T135°C
II M2 G Ex deia IIC T4 BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-
21, BAT95-11
II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W
No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.
Summary of testing:
Test performed in accordance with all of the clauses of according IEC 60079-0
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.
Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.
4.2.2.3 Field wiring connection facilities integral to “e” apparatus or components The circuits of handlamp are permanent N/A
connection. The power supply of it is battery.
4.2.2.4 Connections designed to be used with cable lugs and similar devices The circuits of handlamp are permanent N/A
connection.
The power supply of it is battery.
4.2.3.2 Field wiring connection methods used for factory connections Spring tabs are used to connect the circuit and Pass
battery. They should not be opened in hazardous
areas, see the warning words.
4.2.3.3 Permanent connections All the permanent connections are weld. Pass
4.2.3.5 Terminal bridging connections Terminal bridging connections are not included. N/A
4.3 Clearances The CTI of the insulating material is 540. The Pass
rated power supply is 6-4VDC. The circuit of
Explosion Proof Handlamp is protected by
IEC60079-11, see report IEC60079-11.
4.4.2 Creepage distances between bare conductive parts at different potentials N/A
4.5.3 Insulating parts made of plastics or laminates The surfaces of insulating parts are not N/A
damaged during the manufacture.
4.7.1 General Refer to Clause 26.5 in test report IEC60079-0 and Pass
documents provided by the manufacturer for
relevant data.
4.9.1 Minimum degree of protection The degree of protection of the enclosure complies
with the requirements of IP66. Refer to Clause
26.4.5 in test report IEC60079-0.
4.9.3 Covers of enclosures containing non- intrinsically-safe items shall be adequately The enclosure should not be opened in hazardous N/A
labelled
areas.
5.2.1 Degrees of protection provided by machine enclosures No rotating electrical machines N/A
5.2.4.2 Requirements for the bars of caged rotors No rotating electrical machines N/A
5.2.4.3 Rotor construction and air gap sparking No rotating electrical machines N/A
5.2.4.4.1 Starting current ratio IA/INshall be determined and marked No rotating electrical machines N/A
5.2.4.4.2 Winding temperature sensors associated with protective devices No rotating electrical machines N/A
5.3.2 Minimum distance between lamp and protective cover The rated power of single LED source is less Pass
than 60W. The distance between LED and glass
plate is 24.5mm.
5.3.3.3 Requirements for electrical contact between the lampholder and lamp cap LED sources are welded on the base of it. Pass
5.3.4 Surface temperature of lamps See clause 26.5 in report IEC60079-0 Pass
5.3.5 Temperature of lamp caps See clause 26.5 in report IEC60079-0 Pass
5.3.7.2 Maximum ambient temperature Tubular fluorescent bi-pin lamps are not N/A
included.
5.3.7.3 Temperature class Tubular fluorescent bi-pin lamps are not N/A
included.
5.3.7.4 Lampholders for bi-pin lamps Tubular fluorescent bi-pin lamps are not N/A
included.
5.3.7.5 Enhanced voltage used to initiate discharge within the lamp Tubular fluorescent bi-pin lamps are not N/A
included.
5.3.7.6 Maximum values for torque and Tubular fluorescent bi-pin lamps are not N/A
/or force at each end of the lamp included.
5.3.7.8 Where provided, isolation switch shall Tubular fluorescent bi-pin lamps are not included. N/A
5.4 Caplights and handlights The distance between LED and glass plate is Pass
24.5mm. The mechanically interlock is
provided
that if enclosure was open the current can be cut
off.
5.5
5.5.1 Measuring instruments and instrument transformers and limiting No measuring instruments and N/A
temperatures according to Clause 4.7 instrument transformers
5.5.2 Current transformers and current carrying parts of measuring instruments shall be N/A
able to withstand thermal and dynamic stresses
5.5.6 Guarding against secondary circuit becoming open circuited in service and N/A
marking with an"X"
5.7.6 Incorporation of other types of protection Safety devices are provided. N/A
5.7.7 Disconnection and transportation The enclosure of product should not be opened in Pass
hazardous area. The IP of enclosure is IP66.
5.8 General purpose connection and junction boxes No general purpose connection and junction N/A
boxes
5.9.2 Application of 4.6 and Clause 7 of IEC 60079-0 No resistance heaters N/A
5.9.4 Testing of insulating materials used in a resistance heating device No resistance heaters N/A
5.9.5 Cold start current of the resistance heating device No resistance heaters N/A
5.9.9 Cross-section of the conductors for connections to the resistance heating device No resistance heaters N/A
5.9.10 Determination of the temperature class of a resistance heating device No resistance heaters N/A
5.9.11 Prevention from exceeding the limiting temperature of No resistance heaters N/A
resistance heating device or unit
6.3 Luminaires
6.3.1 Mechanical tests for screw lampholders other than E10 No luminaires designed for mains supply N/A
6.3.3 Sulphur dioxide test for the connection of bi-pin lamp caps to lampholders N/A
6.4 Measuring instruments and instrument transformers No measuring instruments and N/A
instrument transformers
6.8.4 Thermal stability of the insulating materials of the resistance heating device N/A
6.8.5 The test for resistance to impact shall be carried out on two new samples or N/A
prototypes with an apparatus similar to that shown in IEC 60079-0.
6.9 Terminal insulating material tests Terminals are not included. N/A
7 ROUTINE VERIFICATIONS AND ROUTINE TESTS
7.1 Dielectric tests The products are submitted to dielectric test before Pass
delivery. Test voltage is 2500V. duration is 1min.
8 EX COMPONENT CERTIFICATES
8.1 General Not an Ex component N/A
8.2 Terminals N/A
9 MARKING AND INSTRUCTIONS
9.1 General Marking See part IEC60079-0 clause 29. Pass
3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 16 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict
Time tE.................................................................. :
N/A
9.3 Warning markings Warning words can be found in the instructions N/A
A.3.1 Ambient temperature and application of rated voltage and rated frequency N/A
A.7 Motors forming units with converters and the associated protective devices N/A
B.1 Resistance heating devices subjected to mechanical stresses No resistance heating devices and resistance N/A
heating units.
B.3 Resistance heating devices or units having hygroscopic insulating material N/A
B.4.2.2 Safety device sensing the temperature and at least one other protective N/A
parameter
B.4.2.3 Safety device sensing a parameter other than the temperature N/A
Clearance of PCB No greater than 6VDC 0.5 (under the compound) 0.54
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-11:2012
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5, BAT95R1,
BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4
II M2 D Ex tD A21 T135°C
II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W
No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.
Summary of testing:
Test performed in accordance with all of the clauses of according EN 60079-11
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.
Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.
Page 45 of 12
Page 4 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
1 SCOPE
2 NORMATIVE REFERENCES
3 DEFINITIONS
4 GROUPING AND CLASSIFICATION Pass
Page 46 of 12
Page 5 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Page 47 of 12
Page 6 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
6.3.4 Separation distances through casting The fuses and battery Pass
compound protection board of AT-1280 are encapsulated , the
minimum separation distance betweenencapsulated
conductive components and
the free surface of the casting compound is a minimum of
1mm.
Page 48 of 12
Page 7 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
7.4 Primary and secondary cells and batteries The intrinsic safety parts have N/A
no cells and batteries.
7.4.1 General The intrinsic safety parts have N/A
no cells and batteries.
7.4.2 Electrolyte leakage and ventilation The intrinsic safety parts have N/A
no cells and batteries.
7.4.3 Cell voltages The intrinsic safety parts have N/A
no cells and batteries.
7.4.4 Internal resistance of cell or battery The intrinsic safety parts have Pass
External contacts for charging batteries 7.4.9 no cells and batteries.
7.4.5 Batteries in apparatus protected by other The intrinsic safety parts have N/A
means of protection no cells and batteries.
7.4.6 Batteries used and replaced in explosive gas The intrinsic safety parts have N/A
atmospheres no cells and batteries.
7.4.7 Batteries used but not replaced in explosive The intrinsic safety parts have N/A
gas atmospheres no cells and batteries.
7.4.8 There are four series blocking N/A
diodes D1~D4(1N5400) placed in the
battery protection circuit to prevent the batteries from
delivering energy to the external contacts.
Page 49 of 12
Page 8 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Page 50 of 12
Page 9 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Page 51 of 12
Page 10 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Page 52 of 12
Page 11 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Page 53 of 12
Page 12 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict
Clearance of PCB No greater than 6VDC 0.5 (under the compound) 0.54
Page 54 of 12
Page 1 of 5 17ZCTS0920002-5LR
IECEx TEST REPORT EN 60079-31
Explosive atmospheres –
Part 31: Equipment dust ignition protection by enclosure "t"
Report Number.............................: 17ZCTS0920002-5LR
Tested by (+ signature).............. : Kevin Yang
Approved by (+ signature) ....... : King Hu
Date of issue ................................: Sept. 25, 2017
Testing laboratory
Testing Laboratory Name .........: Shenzhen ZCT Technology Co.,Ltd.
Address..........................................: 3/F., Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen,
Guangdong, China.
Applicant’s name.........................: Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.
Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-31:2014
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4
II M2 D Ex tD A21 T135°C
II M2 G Ex deia IIC T4 BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-
21, BAT95-11
II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W
No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.
Summary of testing:
Test performed in accordance with all of the clauses of according EN 60079-31
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.
Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.
Page 57 of 5
Page 4 of 5 17ZCTS0920002-5LR
EN 60079-31
Cl. Requirement – Test Result Verdict
1 SCOPE
2 NORMATIVE REFERENCES
3 TERMS AND DEFINITIONS
4 LEVEL OF PROTECTION Refer to test report Pass
IEC60079-0
4.1 General Refer to test report Pass
IEC60079-0
4.2 Thermal protection The protection lever is “Db”. N/A
4.2.1 Additional requirements for level of protection
N/A
“ta”
4.2.1.1 General The protection lever is “Db”. N/A
4.2.1.2 Protective devices N/A
4.2.1.3 Temperature limitation N/A
5 Construction Pass
5.1 Joint
5.1.1 The rubber rings are provided Pass
General
at the joints.
5.1.2 Refer to test report Pass
Gaskets and seals
IEC60079-0 clause 6.5.
5.1.3 No cemented joints. Operating N/A
Cemented joints rods, spindles and shafts through
the
5.1.4 Operating rods, spindles and shafts enclosure are not included. N/A
5.1 5 Joints CONSTRUCTION Pass
5.1.5 Windows N/A
5.1.5.1 Windows employing a cemented joint cemented joint is not included. N/A
Windows made of glass Pass
employ a gasket joint.
5.1.5.2 Windows employing a gasket joints
Refer to test report
IEC60079-0
5.2 Cable glands and threaded entrie Cable glands are not included. N/A
5.2.1 Cable glands
Thread entries are not
5.2.2 Threaded entries N/A
included.
6 VERIFICATION AND TESTS
6.1 Type tests
Page 58 of 5
Page 5 of 5 17ZCTS0920002-5LR
EN 60079-31
Cl. Requirement – Test Result Verdict
Page 59 of 5
BAT95-T SERIES LED EX-PROOF LIGHT
Product Features
High energy saving LED light source, imported light source, green, low
energy consumption, long life, free maintenance
Technical Parameters
http://www.sinozoc-ex.com/en/ 02
BAT95R2 SERIES LED EX-PROOF LIGHT
Product Features
High energy saving LED light source, imported light source, green, low
energy consumption, long life, free maintenance
Technical Parameters
http://www.sinozoc-ex.com/en/ 04
BAT95-G SERIES LED EX-PROOF LIGHT
Product Features
Technical Parameters
07 http://www.sinozoc-ex.com/en/
BGS-GH SERIES LED EX-PROOF TUBE
Product Features
Stripe light cover is with high light transmittance, not dazzling, the
light is even and soft downy ;
Flame retardant light feet is made of high quality flame retardant
materials, with good heat resistance ;
Highlight energy-saving LED light source, green environmental
protection, with low energy consumption, maintenance
free and other advantages ;
The bottom shell is equipped with a fixed light cover buckle, with
high strength and not easy to damage, so that the light can
be installed quickly.
Technical Parameters
19 http://www.sinozoc-ex.com/en/
LED EMERGENCY EXIT LIGHT
SL-YJM-1
Description:
This product use high quality aluminum shell and glass board as the main material,simple looking design,with durable long life span LED as light
source,it can be used in building,hospital,supermarket and other public places
Electrical Specification
>Input Voltage: AC220/ 50-60Hz
>Power: 3W
>Product Size: 355*22*145mm
>Light Source: LED
>Back Up time: 90/120/180minutes
>Battery Type: Nickel-cadmium
>Battery Voltage: 1.2V
>Material: Aluminum+Glass
>Life Span: 50,000 Hours
>Installation Way: Wall Mounted/Hanging
>Net Weight: 0.6kg
>Gross Weight: 0.65kg
>Package size: 590*380*190mm (20pcs/box)
>Weight: 12KG/ctn
>IP Grade: IP20
Installation Information:
1. First set up accessories and fittings of the light
2. Cut off the power before installation
Tri-proof light manual
I. Application
Applicable to various types of office buildings, department stores, dust-free workshop, underground parking and
other places of lighting.
6.Take out the accessories from the parts package, fix the expansion screw on the position to be installed, and
install the waterproof connector at the inlet;
7.Fix the stainless steel bracket with a screw of Φ4 *30mm, the screw must be tightened, the three anti-lamp buckle
into the stainless steel bracket installed inside;
8.The lamp input is 220V, through the waterproof connector, the brown wire is connected to the power line, the
blue wire is connected to the power line zero, insert the terminal and tighten, and then tighten the waterproof
connector until the sheath can not be pulled out;
9. Install the LED tube into the lamp holder and rotate it face down;
10.When the power supply voltage is within the rated working range of the lamp, turn on the switch and light the
lamp to observe whether the lighting process is normal.
VII. Attention
11.The selection of LED lamp tube according to the actual wiring situation selection, and must be matched with
the wiring scheme, to avoid short circuit.
12.Please turn off the lamp holder power before replacing LED lamps.
13.Can not be used in flammable, explosive, high temperature and corrosive places.
14.When the light is out of order, it should be repaired by professional personnel.