0% found this document useful (0 votes)
236 views68 pages

Striving For An Explosion-Proof Filed Benchmark Enterprise

The document provides certification for LED explosion-proof lights manufactured by Suzhou Zhaochang Electronic Technology Co., Ltd. The lights were tested and certified to comply with European standards for equipment used in explosive atmospheres. Key models certified include the BAT95-T, BAT95-G, BAT95-N, and others. The lights were certified as meeting protection standards for Zone 2 explosive gas atmospheres and Zone 21 and 22 dust atmospheres, with temperature ratings up to 135°C. Testing was performed by Shenzhen ZCT Technology Co., Ltd. and certification was provided by Ente Certificazione Macchine.

Uploaded by

jovan arya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views68 pages

Striving For An Explosion-Proof Filed Benchmark Enterprise

The document provides certification for LED explosion-proof lights manufactured by Suzhou Zhaochang Electronic Technology Co., Ltd. The lights were tested and certified to comply with European standards for equipment used in explosive atmospheres. Key models certified include the BAT95-T, BAT95-G, BAT95-N, and others. The lights were certified as meeting protection standards for Zone 2 explosive gas atmospheres and Zone 21 and 22 dust atmospheres, with temperature ratings up to 135°C. Testing was performed by Shenzhen ZCT Technology Co., Ltd. and certification was provided by Ente Certificazione Macchine.

Uploaded by

jovan arya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 68

Striving for an explosion-proof filed benchmark enterprise

http://www.sinozoc-ex.com/en/
Certificate – Cертификат – 證明書 – Certificate of Compliance
No. 3B170926.SZETD89
Test Report no. 17ZCTS0920002-2ATEX, 17ZCTS0920002-3ATEX, 17ZCTS0920002-4ATEX, 17ZCTS0920002-5ATEX

Certificate’s Holder: Suzhou Zhaochang Electronic Technology Co.,Ltd.


No.98, Yinxin Road, Wuzhong District, Suzhou city, Jiangsu
Province, P.R. China. 215000.

Certification ECM
Mark: European Type
Conformity
Approved
Certificat – 증명서 – ‫ةداهش‬

LED Explosion-proof light


Product:
Model(s): BAT95-T
BAT95-G, BAT95 -N, BAT95-B, 2, BAT95-C,BAT95-D, BAT95-E, BAT95R4,
BAT95R1,BAT95R BAT95R3, BAT95R5, BAT95S7,

BAT95X60,BAT95X35, BAT9512, BAT95-21, BAT95-11

Verification to: Standard:


EN 60079-0:2012/A11:2013, EN 60079-7:2015, EN 60079-11:2012,
EN 60079-31:2014

related to CE Directive(s):
2014/34/EU (Equipment for Explosive Atmospheres)
II M2 G Ex demb IIC T6
II M2 D Ex tD A21 T80℃ IP66
Remark: The product(s) has been verified on a voluntary basis. The product(s) satisfies the requirements of the Certification Mark of ECM, in reference to the above listed Standard(s). The
above Compliance Mark can be affixed on the product(s) accordingly to the ECM regulation about its release and its use. The regulation can be found at www.entecerma.it. This
Certificate of Compliance can be checked for validity at www.entecerma.it
This verification doesn’t imply assessment of the production of the product(s).

Additional information, clarification about the Marking:

We attest that a TCF for the Marking process is in place. Whereas the
Manufacturer is Responsible to start the Marking Certification Procedure through an appointed Notified Body and the perform all the necessary activities,
as required by the Directive and accepted by the Notified Body, before placing the Mark on the product(s).

Date of issue 26 September 2017 Expiry date 25 September 2022

Chief Manager Marco Morina Deputy Manager Amanda Payne

Ente Certificazione Macchine Srl


Via Ca’ Bella, 243 – Loc. Castello di Serravalle – 40053 Valsamoggia (BO) - ITALY
Page 1 of 20 17ZCTS0920002-2LR
IECEx TEST REPORT IEC 60079-0
Electrical equipment for explosive gas atmospheres
Part 0: General requirements
Report Number.............................: 17ZCTS0920002-2LR
Tested by (+ signature).............. :
Kevin Yang King Hu
Approved by (+ signature) ....... : Date of
Sept. 25, 2017
issue ................................:
Testing laboratory
Shenzhen ZCT Technology Co.,Ltd.
Testing Laboratory Name .........:
3/F., Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen,
Address..........................................:
Guangdong, China.
Applicant’s name.........................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-0:2012/A11:2013
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4

II M2 D Ex tD A21 T135°C

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 20
Page 2 of 20 17ZCTS0920002-2LR
Copy of marking plate

LED Explosion-proof light BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,

II M2 G Ex deia IIC T4 II M2 D Ex tD BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-

21, BAT95-11
A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W

No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.

Summary of testing:
Test performed in accordance with all of the clauses of according IEC 60079-0

Possible test case verdicts:


– test case does not apply to the test object ...... : N/A
– test object does meet the requirement............ : P(Pass)
– test object does not meet the requirement...... : F(Fail)
Testing ..................................................................
Date of receipt of test item .................................. : Sept, 06, 2017
Date(s) of performance of test .............................. : Sept, 06, 2017 to Sept, 25, 2017

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 20
Page 3 of 20 17ZCTS0920002-2LR

General remarks:

The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.

Throughout this report a comma (point) is used as the decimal separator.

Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.

This test report includes:


Annex I: Photo documentation, 2 pages
General product information:

LED Explosion-proof light, models BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4,
BAT95R5, BAT95S7, BAT95X60, BAT95X35,
BAT9512, BAT95-21, BAT95-11

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 5 of 20
Page 4 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

1 SCOPE
2 NORMATIVE REFERENCES
3 TERMS AND DEFINITIONS
4 Pass
CONSTRUCTIONAL REQUIREMENTS FOR ALL
ELECTRICAL APPARATUS
4.1 General Pass
4.2 Electrical connections
4.2.1 General
Pass
The circuits of handlamp are permanent connection.

All conductors firmly installed. Pass


Pass
The power supply of it is battery. The circuits are protected by "ib"(except the battery).

For the rechargeable battery of A-1280, the charge circuit is not working during the Pass
normal working condition.

And it only can be charged in safety area. Pass


4.2.2 Field wiring connections
4.2.2.1 General
The circuits of handlamp are permanent connection. The power supply of it is battery. Pass
N/A 4.2.2.2

Pass
Connections made using terminals complying with
IEC 60947-7-1, IEC 60947-7-
2, IEC 60999-1, or IEC 60999-2
Pass
The circuits of handlamp are permanent connection.

The power supply of it is battery. N/A 4.2.2.3 Field wiring connection facilities integral to Pass
“e” apparatus or components The circuits of handlamp are permanent connection.

The power supply of it is battery. N/A


4.2.2.4 Connections designed to be used with cable Pass
lugs and similar devices
The circuits of handlamp are permanent Pass
connection.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 6 of 20
Page 5 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

The power supply of it is battery. N/A


4.2.2.5 Connections using permanent arrangements Pass
The circuits of handlamp are permanent connection.

The power supply of it is battery. N/A


4.2.3 Factory connections
4.2.3.1 General The circuits of handlamp are
factory connections.
The power supply of it is battery. Pass
4.2.3.2 Field wiring connection methods used for
factory connections
Spring tabs are used to connect the circuit and N/A
battery.
They should not be opened in hazardous Pass
areas, see the warning words.
4.2.3.3 Permanent connections All the permanent N/A
connections are weld. Pass
4.2.3.4 Pluggable connections Pluggable connections N/A
are not included.
4.2.3.5 Terminal bridging connections
Terminal bridging connections are not N/A
included.
4 APPARATUS GROUPING AND
TEMPERATURE CLASSIFICATION
4.1 Group I N/A
4.2 Group II IIC Pass
4.3 Group III IIIA Pass
4.4 Equipment for a particular explosive No particular explosive N/A
atmosphere atmosphere considered.
5 TEMPERATURES
5.1 Environmental influences Pass
5.1.1 Ambient temperatures -15℃≤Ta≤+40℃. Pass
External source of heating or cooling No external source of heating N/A
5.1.2
or cooling.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 7 of 20
Page 6 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

5.2 Service temperature Using maximum surface Pass


temperature instead of maximum service temperature is
approved by the manufacturer. See 26.5.1.3.

5.3 Maximum surface temperature Pass


5.3.1 Determination of maximum surface Refer to Cl. 26.5.1 in test Pass
temperature report IEC60079-0 for determination of maximum
surface temperature.

5.3.2 Limitation of maximum surface temperature Pass


5.3.2.1 Group I electrical equipment Group II and Group III N/A
Refer to Cl. 26.5.1 in test
5.3.2.2 Group II electrical equipment Pass
report IEC60079-0.
Refer to Cl. 26.5.1 in test
5.3.2.3 Group III electrical equipment Pass
report IEC60079-0
5.3.2.3.1 Maximum surface temperature determined Refer to Cl. 26.5.1 in test Pass
without a dust layer report IEC60079-0
5.3.2.3.2 Maximum surface temperature with respect to Db equipment N/A
dust layers
5.3.3 Small component temperature for Group I or No small components. N/A
Group II electrical equipment
6 REQUIREMENTS FOR ALL ELECTRICAL -
EQUIPMENT
6.1 General The samples comply with the Pass
requirements of IEC 60079-0, IEC60079-7, IEC60079-
11 and IEC60079-31.

6.2 Mechanical strength of equipment Refer to Cl. 26.4 in test report Pass
IEC60079-0. See 26.5.1.3.
6.3 Opening times N/A
6.4 Circulating currents No circulating currents. N/A
6.5 Gasket retention 1. A rubber ring is made of Pass
silicon between lamp head and enclosure.
The rubber ring is in the groove of the
enclosure.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 8 of 20
Page 7 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

2. A rubber ring is made of


silicon between lamp head and glass plate. The
rubber
ring is pressed by locking ring.
6.6 Electromagnetic and ultrasonic energy No electromagnetic and N/A
radiating equipment ultrasonic energy radiating equipment

6.6.1 Radio frequency sources N/A


6.6.2 Lasers or other continuous wave sources N/A
6.6.3 Ultrasonic sources N/A
7 NON-METALLIC ENCLOSURES AND Pass
NON-METALLIC PARTS OF ENCLOSURES
7.1 General Pass
7.1.1 Applicability The enclosure and rubber Pass
rings comply this clause.
7.1.2 Specification of materials The manufacture documents Pass
show the detail of the non-metallic
materials.
7.1.3 Plastic materials The enclosure is made of PC. Pass

Its type is PP. RTI value of it is 105℃.

7.1.4 Elastomeric materials The rubber rings are made of Pass


silicon rubber.
The long time working temperature of it is
-100 ℃~+250 ℃ 。

7.2.1 Tests for thermal endurance See clause 26.8 and 26.9 in Pass
this report.
7.2 Thermal endurance Pass
7.2.2 Material selection The COT of the sealing strip Pass
and RTI of the enclosure is 20K higher than the
maximum
operating temperature. Refer to Clause 26.5, 7.1.3 and
7.1.4.

7.3 Resistance to light Resistance to light was carried Pass


out according to clause 26.10.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 9 of 20
Page 8 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

7.4 Electrostatic charges on external non-metallic Pass


materials
7.4.1 Applicability The enclosure is made by PC. Pass
7.4.2 Avoidance of a build-up of electrostatic charge The surface resistance is Pass
on Group I or Group II electrical equipment tested on the parts of enclosure and carried out
according to clause 26.13. The surface resistance is
3.0×101Ω, less than 109Ω.

7.4.3 Avoidance of a build-up of electrostatic charge No using plastic which is Pass


on equipment for Group III covered by conductive material.

7.5 Threaded holes Only metric thread holes Pass


included. The thread holes are compatible with the
plastic
material of the enclosure.
8 METALLIC ENCLOSURES AND METALLIC N/A
PARTS OF ENCLOSURES
8.1 Material Composition The enclosure is made of PC. N/A
8.1.1 Group I The enclosure is made of PC. N/A
8.1.2 Group II The enclosure is made of PC. N/A
8.1.3 Group III The enclosure is made of PC. N/A
8.2 Threaded Holes N/A
9 FASTENERS N/A
9.1 General Fasteners are not included. N/A
9.2 Special fasteners Fasteners are not included. N/A
9.3 Holes for special fasteners Fasteners are not included. N/A
9.3.1 Thread engagement Fasteners are not included. N/A
9.3.2 Tolerance and clearance Fasteners are not included. N/A
9.3.3 Hexagon socket set screw Fasteners are not included. N/A
10 INTERLOCKING DEVICES No interlocking devices N/A
11 BUSHINGS No bushings.. N/A
Cemented joints are not N/A
12 MATERIALS USED FOR CEMENTING
included.
13 EX COMPONENTS Ex components are not N/A
included.
13.1 General N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 10 of 20
Page 9 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

13.2 Mounting N/A


13.3 Internal Mounting N/A
13.4 External Mounting N/A
14 CONNECTION FACILITIES AND TERMINAL
COMPARTMENTS
14.1 General The power supply of N/A
Explosion Proof Handlamp is battery.

14.2 Termination compartment N/A


14.3 Type of protection N/A
14.4 Creepage and clearance N/A
15 ONNECTION FACILITIES FOR EARTHING N/A
OR BONDING CONDUCTORS
15.1 Equipment requiring earthing Portable equipment N/A
15.1.1 Internal Portable equipment N/A
15.1.2 External Portable equipment N/A
15.2 Equipment not requiring earthing Portable equipment with Pass
plastic enclosure
15.3 Size of conductor connection Portable equipment N/A
15.4 Protection against corrosion Portable equipment N/A
15.5 Secureness of electrical connections Portable equipment N/A
16 ENTRIES INTO ENCLOSURES N/A
16.1 General Portable equipment with battery Portable equipment with N/A
power supply battery
16.2 Identification of entries Portable equipment with N/A
battery power supply
16.3 Cable glands power supply N/A
16.4 Blanking elements Portable equipment with N/A
battery power supply
16.5 Temperature at branching point and entry Portable equipment with N/A
point battery power supply
16.6 Portable equipment with N/A
Electrostatic charges of cable sheaths battery power supply
17 SUPPLEMENTARY REQUIREMENTS FOR N/A
ROTATING ELECTRICAL MACHINES
No rotating electrical
17.1 Fans and fan hoods N/A
machines.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 11 of 20
Page 10 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

17.2 Ventilation openings for external fans No rotating electrical N/A


machines.
17.3 Construction and mounting of the ventilation No rotating electrical N/A
systems machines.
17.4 No rotating electrical N/A
Clearances for the ventilating systems
machines.
17.5 Materials for external fans and fan hoods No rotating electrical N/A
machines.
17.6 Equipotential bonding conductors Flammable No rotating electrical N/A
dielectric machines.
18 SUPPLEMENTARY REQUIREMENTS FOR N/A
SWITCHGEAR
18.1 Flammable dielectric Switchgear is not included.
18.2 Disconnectors No disconnectors. N/A
18.3 Group I – Provisions for locking Group II.
18.4 Doors and covers Doors and covers are not N/A
included.
19 SUPPLEMENTARY REQUIREMENTS FOR The fuse is protected by "ib". N/A
FUSES The Explosion Proof Handlamp should not be
opened in hazardous areas.

20 SUPPLEMENTARY REQUIREMENTS FOR N/A


PLUGS, SOCKETS OUTLETS AND CONNECTORS

No plugs, sockets outlets and


20.1 Interlocking N/A
connectors.
No plugs, sockets outlets and
20.1.1 Explosive gas atmospheres N/A
connectors.
No plugs, sockets outlets and
20.1.2 Explosive dust atmospheres N/A
connectors.
20.2 Energized plugs N/A
21 Supplementary Requirement for Luminaires Pass
21.1 General A glass plate is provided to Pass
protect the light source. For the impact test, See
clause 26.4.2

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 12 of 20
Page 11 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

21.2 The enclosure should not be Pass


Covers for luminaires of EPL Gb or EPL Db
opened in hazardous area.
21.3 No plugs, sockets outlets and N/A
Covers for luminaires of EPL Gc or EPL Dc
connectors.
21.4 Special lamps Gb and Db equipment No N/A
special lamp.
22 SUPPLEMENTARY REQUIREMENTS FOR N/A
CAPLIGHTS AND HANDLIGHTS
22.1 Group I caplights Group II and III equipment. N/A
22.2 Group II and Group II caplights and handlights No leakage at all working Pass
directions.
23 APPARATUS INCORPORATING CELLS AND N/A
BATTERIES
23.1 General N/A
23.2 Batteries N/A
23.3 Cell types N/A
23.4 Cells in a battery N/A
23.5 Ratings of batteries N/A
23.6 Interchangeability N/A
23.7 Charging of primary batteries N/A
23.8 Leakage N/A
23.9 Connections N/A
23.10 Orientation N/A
23.11 Replacement of cells or batteries N/A
23.12 Replaceable battery pack N/A
24 DOCUMENTATION Relevant documentation Pass
provided by the manufacturer has been assessed.

25 COMPLIANCE OF PROTOTYPE OR Pass


SAMPLE WITH DOCUMENTS
26 TYPE TESTS
26.1 General Tests were carried out Pass
according to IEC 60079-0, IEC 60079-1, IEC 60079-7,
IEC60079-11 and IEC
60079-31.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 13 of 20
Page 12 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

26.2 Test configuration Tests were carried out under Pass


the most unfavorable conditions.

26.3 The equipment is protected by N/A


Tests in explosive test mixtures
“e”, “ib” and “t”.
26.4 Tests of enclosures
26.4.1 Order of tests Pass
26.4.1.1 Metallic enclosures, metallic parts of The enclosure of this product Pass
enclosures and glass of parts of enclosures is made by non-metallic material.

26.4.1.2 Non-metallic enclosures or non-metallic parts See cluase 26.4.1.2.2 Pass


of enclosures
26.4.1.2.1 Group I electrical equipment Group II and Group III N/A
Group II and Group III electrical equipment 2 samples were submitted to
the tests according to the following sequence:

26.4.1.2.2 1. Thermal endurance to heat Pass


2. Thermal endurance to cold
3. Impact test
4. Drop test
5.IP test(the cover was opened and re-closed before IP
test)
6.Any other tests specific to the type of protection
concerned

26.4.2 Resistance to impact carried out on three glass Pass


plate samples. Impact once at each sample. The impact
energy is 7J. At the ambient
temperature of 24℃, test was

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 14 of 20
Page 13 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

Impact tests for the enclosure


were carried out on two samples. Impact once at two
different positions on each sample at 69℃
respectively
with 7J impact energy; then impact once at two
different positions on each sample at
-20℃

26.4.3 Drop test The drop test was carried out Pass
at the temperature of -15. The battery was connected to
the test sample. The position of the sample for the drop
test is the most unfavorable condition. respectively with
7J impact energy

26.4.4 Acceptance criteria No damage affecting the Pass


explosion-proof performance has been found.

26.4.5 Degree of protection (IP) by enclosures Pass


26.4.5.1 Test procedure The test procedure is Pass
according to IEC60529.
26.4.5.2 Acceptance criteria The protection degree is IP66. Pass
No ingress of dust or water after tests for degree of
protection by enclosure.

26.5 Thermal tests Pass


26.5.1 Temperature measurement Pass
26.5.1.1 General The Portable emergency Pass
lighting system is vertically upward during
temperature
measurement.
The AT-1080 and AT1280
was chosen as the test samples.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 15 of 20
Page 14 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

26.5.1.2 Service temperature Using maximum surface Pass


temperature instead of maximum service temperature is
approved by the manufacturer. See 26.5.1.3.

26.5.1.3 Maximum surface temperature The measuring devices are Pass


arranged that they do not significantly affect the thermal
behaviour of the electrical apparatus.

The temperature rise for


different positions of the sample are as follow:

Table 26.5.1.3 Maximum surface temperature


Position Temperature rise(K) Verdict
Enclosure(PC) 14 P
Glass plate 12 P
Rubber ring 12 P

For the temperature rise of PCB, see report in Pass


EN 60079-11.
Under the ambient temperature 40℃, the maximum temperature is 56℃.
The temperature class of product complies with T4.

26.5.2 Thermal shock test The test was carried out on Pass
glass plate.
The temperature of glass plate

is 56(at ambient temperature 40℃).

Water was sprayed the on

glass plate at 10℃, and the glass plate was not

26.5.3 Small component ignition test (G roup I and Group II) broken. N/A
The components on PCB N/A
26.5.3.1 General
comply with T4
The components on PCB N/A
26.5.3.2 Procedure
comply with T4
Shenzhen ZCT Technology Co., Ltd.
3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 16 of 20
Page 15 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

The components on PCB N/A


26.5.3.3 Acceptance criteria
comply with T4
26.6 Torque test for bushings N/A
26.6.1 Test procedure No bushings. N/A
26.6.2 Acceptance criteria No bushings. N/A
26.7 General Pass
26.7.1 Non-metallic enclosures or non-metallic parts Pass
of enclosures
26.7.2 Test temperatures For the upper temperature of Pass
the non-metallic parts, the maximum service temperature
increased by 10K; for the lower temperature of the
non-metallic parts, the maximum service temperature
reduced by 5K (refer to Clause
26.5 for temperature measurement).

26.8 Thermal endurance to heat The samples were stored for Pass
28 days at 90% relative humidity at a temperature of
80℃.

26.9 Thermal endurance to cold The sample was stored for 24 Pass
hours at a temperature of
-20℃.
26.10 Resistance to light Tests were carried out Pass
according to the standard.
26.10.1 Test procedure Size of test bars: Pass
80mm×10mm×4mm; number of test bars: 12;
temperature
of black panel: (65 ±3)℃; exposure time:
1000h.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 17 of 20
Page 16 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

26.10.2 Acceptance criteria The impact bending strength Pass


following exposure in the case of an impact on the
exposed side shall be at least 50% of the corresponding
value measured on the unexposed
test pieces.

26.11 Resistance to chemical agents for Group I Group II and Group III N/A
electrical equipment Earth continuity
26.12 Earthing is not included. N/A
26.13 of parts of enclosures of non-metallic materials enclosure and carried out Pass
Surface resistance test of parts according to the standard. The surface resistance
is
3.0×103 The surface resistance is tested on the
parts of Ω,less than 109Ω.

26.14 Introduction This test is not required. N/A


26.14.1 Charging tests N/A
26.14.2 Principle of the test This test is not required. N/A
26.14.3 Samples and test apparatus This test is not required. N/A
26.14.4 Ambient conditions This test is not required. N/A
26.14.5 Conditioning This test is not required. N/A
26.14.6 Determination of the most efficient charging method N/A
26.14.6.1 Method A: Rubbing with a pure polyamide This test is not required. N/A
cloth
26.14.6.2 Method B: Rubbing with a cotton cloth This test is not required. N/A
26.14.6.3 Method C: Charging by influence with a d.c. This test is not required. N/A
high-voltage power supply
26.14.7 Assessment of discharge This test is not required. N/A
26.15 Test procedure This test is not required. N/A
26.15.1 Measurement of capacitance N/A
26.15.2 Acceptance criteria This test is not required. N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 18 of 20
Page 17 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

27 Routine tests The Portable emergency Pass


lighting system was submitted to specifications of
power-frequency withstand voltage test. Test
voltage: 2500V. Duration:
1min, No insulation breakdown, flashover,
leakage current increasing obviously or voltage
dropping suddenly etc. phenomena. Refer to the
document provided by the

28.1 28 Conformity with the documentation The manufacturer carries out Pass
MANUFACTURER'S RESPONSIBILITY the verifications or tests. The sample conforms to the
documentation.

28.2 Certificate The samples comply with the Pass


requirements of IEC 60079-0, IEC 60079-7, IEC
60079-11, IEC60079-31.

28.3 Responsibility for marking The Portable emergency Pass


lighting system is designed and manufactured,
assessed
and tested according to IEC 60079-0, IEC 60079-7,
IEC
60079-11, IEC 60079-31. The
sample complies with the document. Refer to Cl. 29
for the content of nameplate.

29 MARKING The nameplate complies with Pass


the requirements of IEC60079-0, IEC600797, IEC
6007911 and IEC60079-31.

29.1 Location The nameplate made of Pass


SUS304 is fixed on the handle of the enclosure with 4
rivets.
29.2 General Pass

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 19 of 20
Page 18 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

29.3 Ex marking for explosive gas atmospheres Ex e ib IIC T4Gb For the Pass
nameplate, see cover of this report.

29.4 Ex marking for explosive dust atmospheres Ex t IIIC T130℃ Db IP66 Pass
29.5 Combined types of protection There is two protection type Pass
“d” and “e”. Protection type of the enclosure is “e”,
protection
type of circuit is “ib”.
29.7 Ga using two independent Gb types of Only one Gb protection. N/A
protection
29.6 Multiple types of protection Combined types of protection, N/A
see clause 29.5.
29.8 Ex components N/A
29.9 Small equipment and small Ex components Ex components are not N/A
included. No small equipment and small Ex
components
29.10 Extremely small equipment and extremely No extremely small equipment N/A
small Ex components and extremely small Ex components.

29.11 Warning markings The warning words are Pass


specified in the nameplate.
29.12 Alternate marking of equipment protection No alternate marking. N/A
levels (EPLs)
29.12.1 Alternate marking of type of protection for N/A
explosive gas atmospheres
29.12.2 Alternate marking of type of protection for N/A
explosive dust atmospheres
29.13 Cells and batteries N/A
30 INSTRUCTIONS

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 20 of 20
Page 19 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

30.1 General The instruction manual Pass


includes application range, model implication,
compliances, working conditions, technical
parameters, installation,
usage and maintenance, outline and installation
dimension, electric schematic diagram, transportation,
storage and ordering information.

30.2 Cells and batteries N/A


Annex A SUPPLEMENTARY REQUIREMENTS FOR N/A
(Normative) CABLE GLANDS
A.1 General No cable glands. N/A
A.2 Constructional requirements
A.2.1 Cable sealing No cable glands. N/A
A.2.2 Filling compounds No cable glands. N/A
A.2.3 Clamping
A.2.3.1 General No cable glands. N/A
A.2.3.2 Group II or Group III cable glands No cable N/A
glands.
A.2.4 Lead-in of cable
A.2.4.1 Sharp edges No cable glands. N/A
A.2.4.2 Point of entry No cable glands. N/A
A.2.5 Released by a tool No cable glands. N/A
A.2.6 Fixing No cable glands. N/A
A.2.7 Degree of protection No cable glands. N/A
A.3 Type tests
Tests of clamping of non-armoured and N/A
A.3.1
braided cables
A.3.1.1 Cable glands with clamping by the sealing ring No cable glands. N/A
Cable glands with clamping by the filling No cable glands. N/A
A.3.1.2
compound
Cable glands with clamping by means of a No cable glands. N/A
A.3.1.3
clamping device

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 21 of 20
Page 20 of 20 17ZCTS0920002-2LR
IEC 60079-0
Cl. Requirement – Test Result Verdict

A.3.1.4 Tensile test No cable glands. N/A


A.3.1.5 Mechanical strength No cable glands. N/A
A.3.2 Tests of clamping of armoured cables N/A
Tests of clamping where the armourings are N/A
A.3.2.1 No cable glands.
clamped by a device within the gland
A.3.2.1.1 Tensile test No cable glands. N/A
A.3.2.1.2 Mechanical strength No cable glands. N/A
Tests of clamping where the armourings are N/A
A.3.2.2 No cable glands.
not clamped by a device within the gland
A.3.3 Type test for resistance to impact No cable glands. N/A
Test for degree of protection (IP) of cable N/A
A.3.4 No cable glands.
glands
A.4 Marking
A.4.1 Marking of cable glands No cable glands. N/A
A.4.2 Marking of cable sealing rings No cable glands. N/A
Annex B Table B.1- Clauses with which Ex components N/A
(Normative) shall comply

- End of Test Report -

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 22 of 20
Page 1 of 20 17ZCTS0920002-3LR
IECEx TEST REPORT EN 60079-7
Electrical equipment for explosive gas
atmospheres Part 7: Increased safety“e”

Report Number.............................: 17ZCTS0920002-3LR


Tested by (+ signature).............. : Approved by (+ Kevin Yang King Hu
signature) ....... : Date of issue ................................: Sept. 25, 2017
Testing laboratory
Shenzhen ZCT Technology Co.,Ltd.
Testing Laboratory Name .........:
3/F., Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen,
Address..........................................: Guangdong, China.
Applicant’s name.........................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-7:2015
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4

II M2 D Ex tD A21 T135°C

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 2 of 20 17ZCTS0920002-3LR
Copy of marking plate

LED Explosion-proof light BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,

II M2 G Ex deia IIC T4 BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-

21, BAT95-11
II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W

No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.

Summary of testing:
Test performed in accordance with all of the clauses of according IEC 60079-0

Possible test case verdicts:


– test case does not apply to the test object ...... : N/A
– test object does meet the requirement............ : P(Pass)
– test object does not meet the requirement...... : F(Fail)
Testing ..................................................................
Date of receipt of test item .................................. : Sept, 06, 2017
Date(s) of performance of test .............................. : Sept, 06, 2017 to Sept, 25, 2017

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 3 of 20 17ZCTS0920002-3LR

General remarks:

The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.

Throughout this report a comma (point) is used as the decimal separator.

Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.

This test report includes:


Annex I: Photo documentation, 2 pages
General product information:

LED Explosion-proof light, models BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5, BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7,
BAT95X60, BAT95X35, BAT9512, BAT95-21, BAT95-11

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 4 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

Clause Requirement – Test Result – Remark Verdict


1 SCOPE
2 NORMATIVE REFERENCES

CONSTRUCTIONAL REQUIREMENTS FOR Pass


ALL ELECTRICAL APPARATUS
4.1 General Pass
4.2 Electrical connections Pass
4.2.1 General The circuits of handlamp are permanent connection.
All conductors firmly installed. The power supply of
it is battery. The circuits are protected by "ib"(except
the battery).
For the rechargeable battery of 18650-10S9P, the
charge circuit is not working during the normal
working condition.
And it only can be charged in safety area.

4.2.2 Field wiring connections


4.2.2.1 General The circuits of handlamp are permanent N/A
connection. The power supply of it is battery.

4.2.2.2 The circuits of handlamp are permanent N/A


Connections made using terminals complying with IEC connection. The power supply of it is battery.
60947-7-1, IEC 60947-7-2, IEC
60999-1, or IEC 60999-2

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 5 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

4.2.2.3 Field wiring connection facilities integral to “e” apparatus or components The circuits of handlamp are permanent N/A
connection. The power supply of it is battery.

4.2.2.4 Connections designed to be used with cable lugs and similar devices The circuits of handlamp are permanent N/A
connection.
The power supply of it is battery.

4.2.2.5 The circuits of handlamp are permanent N/A


Connections using permanent arrangements connection. The power supply of it is battery.

4.2.3 Factory connections


4.2.3.1 General The circuits of handlamp are factory Pass
connections. The power supply of it is battery.

4.2.3.2 Field wiring connection methods used for factory connections Spring tabs are used to connect the circuit and Pass
battery. They should not be opened in hazardous
areas, see the warning words.

4.2.3.3 Permanent connections All the permanent connections are weld. Pass

4.2.3.4 Pluggable connections Pluggable connections are not included. N/A

4.2.3.5 Terminal bridging connections Terminal bridging connections are not included. N/A

4.3 Clearances The CTI of the insulating material is 540. The Pass
rated power supply is 6-4VDC. The circuit of
Explosion Proof Handlamp is protected by
IEC60079-11, see report IEC60079-11.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 6 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

4.4 Creepage distances


4.4.1 Required values of creepage distance The CTI of the insulating material is 540. The Pass
rated power supply is 6-4VDC. The circuit of
LED is protected by
IEC60079-11, see report IEC60079-11.

4.4.2 Creepage distances between bare conductive parts at different potentials N/A

4.4.3 Effects of ribs and grooves N/A


4.5 Solid electrical insulating materials
4.5.1 Clarification of the term solid electrical insulating materials Reference only. Pass

4.5.2 Mechanical characteristics Pass


The RTI of insulating material is 105℃. And
thermal endurance tests were carried on the
samples.

4.5.3 Insulating parts made of plastics or laminates The surfaces of insulating parts are not N/A
damaged during the manufacture.

4.6 Windings N/A

4.6.1 Insulated conductors to comply with either No windings


4.6.1.1 or 4.6.1.2
4.6.1.1 Two layers of insulation No windings N/A
4.6.1.2 Enamelled round winding wires No windings N/A
4.6.2 Windings following fastening and wrapping No windings N/A
4.6.3 Minimum nominal conductor dimension No windings N/A
4.6.4 Sensing elements of RTDs No windings N/A
4.7 Temperature limitations

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 7 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

4.7.1 General Refer to Clause 26.5 in test report IEC60079-0 and Pass
documents provided by the manufacturer for
relevant data.

4.7.2 Conductors In the temperature test, original conductors Pass


was used. After the test,
there is no reduction of mechanical strength,
unacceptable mechanical stress due to thermal
expansion, or damage to neighbouring electrical
insulating parts.

4.7.3 Insulated windings No insulated windings N/A


4.7.4 Winding Protection No insulated windings N/A
4.8 Wiring internal to apparatus The conductors are firmly installed. And they Pass
are located in grooves and cannot be moved by
mechanical strength.

4.9 Degrees of protection provided by enclosures Pass

4.9.1 Minimum degree of protection The degree of protection of the enclosure complies
with the requirements of IP66. Refer to Clause
26.4.5 in test report IEC60079-0.

4.9.2 Accumulation of condensation within enclosure No accumulation of condensation N/A


within enclosure.

4.9.3 Covers of enclosures containing non- intrinsically-safe items shall be adequately The enclosure should not be opened in hazardous N/A
labelled
areas.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 8 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

And when the enclosure is


opened, the power supply will be cut off automatically.

4.10 Fasteners Group II and III N/A


5 SUPPLEMENTARY REQUIREMENTS FOR N/A
SPECIFIC ELECTRICAL APPARATUS
5.1 General Pass
5.2 Rotating electrical machines N/A

5.2.1 Degrees of protection provided by machine enclosures No rotating electrical machines N/A

5.2.2 Internal fans No rotating electrical machines N/A

5.2.3 Minimum radial air gap No rotating electrical machines N/A

5.2.4 Machines with cage rotors N/A


5.2.4.1 Requirements for machines with caged rotors No rotating electrical machines N/A

5.2.4.2 Requirements for the bars of caged rotors No rotating electrical machines N/A

5.2.4.3 Rotor construction and air gap sparking No rotating electrical machines N/A

5.2.4.4 Limiting temperature of the rotor No rotating electrical machines N/A

5.2.4.4.1 Starting current ratio IA/INshall be determined and marked No rotating electrical machines N/A

5.2.4.4.2 Winding temperature sensors associated with protective devices No rotating electrical machines N/A

5.2.4.5 Converter-fed motors No rotating electrical machines N/A

5.2.4.6 Information on thermal protection No rotating electrical machines N/A

5.2.5 Winding requirements No rotating electrical machines N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 9 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

5.2.6 Stator winding terminals No rotating electrical machines N/A

5.2.7 Stator winding insulation system No rotating electrical machines N/A

5.2.8 Bearing seals and shaft seals N/A


5.2.8.1 Non-rubbing seals and labyrinths No rotating electrical machines N/A

5.2.8.2 Rubbing seals No rotating electrical machines N/A

5.3 Luminaires Pass


5.3.1 Light source LED and its base are protected by “ib”. Pass

5.3.2 Minimum distance between lamp and protective cover The rated power of single LED source is less Pass
than 60W. The distance between LED and glass
plate is 24.5mm.

5.3.3 Lampholders and lamp caps N/A


5.3.3.1 Screw lampholders and lamp caps N/A
Screw lampholders and lamp caps are not
included.
5.3.3.2 Other lampholders and lamp caps lampholders and lamp caps are not part of N/A
enclosure.

5.3.3.3 Requirements for electrical contact between the lampholder and lamp cap LED sources are welded on the base of it. Pass

5.3.4 Surface temperature of lamps See clause 26.5 in report IEC60079-0 Pass

5.3.5 Temperature of lamp caps See clause 26.5 in report IEC60079-0 Pass

5.3.6 Limiting temperatures See clause 26.5 in report IEC60079-0 Pass

5.3.7 Luminaires for tubular fluorescent bi-pin lamps N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 10 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

5.3.7.1 General Tubular fluorescent bi-pin lamps are not N/A


included.

5.3.7.2 Maximum ambient temperature Tubular fluorescent bi-pin lamps are not N/A
included.

5.3.7.3 Temperature class Tubular fluorescent bi-pin lamps are not N/A
included.
5.3.7.4 Lampholders for bi-pin lamps Tubular fluorescent bi-pin lamps are not N/A
included.

5.3.7.5 Enhanced voltage used to initiate discharge within the lamp Tubular fluorescent bi-pin lamps are not N/A
included.

5.3.7.6 Maximum values for torque and Tubular fluorescent bi-pin lamps are not N/A
/or force at each end of the lamp included.

5.3.7.7 Tubular fluorescent bi-pin lamps are not N/A


Reliability under corrosion and vibration conditions included.

5.3.7.8 Where provided, isolation switch shall Tubular fluorescent bi-pin lamps are not included. N/A

de-energize each lampholder when the protective cover is removed

5.4 Caplights and handlights The distance between LED and glass plate is Pass
24.5mm. The mechanically interlock is
provided
that if enclosure was open the current can be cut
off.

5.5
5.5.1 Measuring instruments and instrument transformers and limiting No measuring instruments and N/A
temperatures according to Clause 4.7 instrument transformers

5.5.2 Current transformers and current carrying parts of measuring instruments shall be N/A
able to withstand thermal and dynamic stresses

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 11 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

5.5.3 Temperature attained during the passage of a current N/A

5.5.4 Measuring instruments supplied by current transformers N/A

5.5.5 Measuring instruments with moving coils not permitted N/A

5.5.6 Guarding against secondary circuit becoming open circuited in service and N/A
marking with an"X"

5.6 Transformers other than instrument transformers No transformers N/A

5.7 Batteries N/A


5.7.1 Secondary batteries with capacity greater than 25 Ah

5.7.1.1 General N/A


5.7.1.2 Battery containers N/A
5.7.1.3 Cells N/A
5.7.1.4 Connections N/A
5.7.2 Primary and secondary batteries with capacity up to 25 Ah Pass

5.7.3 Release of flammable gas N/A


5.7.4 Charging of cells N/A
5.7.5 Discharge of cells Protection circuit for battery are provided. The Pass
circuit can prevent the battery from deep
discharging and excessive current.

5.7.6 Incorporation of other types of protection Safety devices are provided. N/A
5.7.7 Disconnection and transportation The enclosure of product should not be opened in Pass
hazardous area. The IP of enclosure is IP66.

5.8 General purpose connection and junction boxes No general purpose connection and junction N/A
boxes

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 12 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

5.9 Resistance heaters (other than trace heaters)


5.9.1 Supplementary requirements for the resistance heating devices and resistance No resistance heaters N/A
heating units

5.9.2 Application of 4.6 and Clause 7 of IEC 60079-0 No resistance heaters N/A

5.9.3 Temperature coefficient of heating resistors No resistance heaters N/A

5.9.4 Testing of insulating materials used in a resistance heating device No resistance heaters N/A

5.9.5 Cold start current of the resistance heating device No resistance heaters N/A

5.9.6 The manufacturer shall specify No resistance heaters N/A


an electrical protective device for use with each resistance heating device or
unit.
5.9.7 Requirements for electrically conductive covering No resistance heaters N/A

5.9.8 Electrical insulation of the heating resistors No resistance heaters N/A

5.9.9 Cross-section of the conductors for connections to the resistance heating device No resistance heaters N/A

5.9.10 Determination of the temperature class of a resistance heating device No resistance heaters N/A

5.9.11 Prevention from exceeding the limiting temperature of No resistance heaters N/A
resistance heating device or unit

5.9.12 Protection offered by a safety device No resistance heaters N/A


5.9.13 Requirements for resistance heating devices and units No resistance heaters N/A

5.10 Other electrical apparatus N/A


6 TYPE VERIFICATIONS AND TYPE TESTS Pass
6.1 Dielectric strength (see appended table 6.1) Pass
6.2 Rotating electrical machines
6.2.1 Machines with cage rotors No rotating electrical machines N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 13 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

6.2.2 Test conditions required for rotating electrical machines N/A

6.2.3 Additional tests for machines


6.2.3.1 Stator winding insulation system
6.2.3.1.1 Test required for motor components N/A

6.2.3.1.2 Arrangements for stator connection cables N/A

6.2.3.1.3 Insulation systems and connection cables N/A

6.2.3.1.4 Insulation systems and connecting cables - Impulse test N/A

6.2.3.2 Cage rotor construction


6.2.3.2.1 Tests to be carried out using a machine representative of a finished machine N/A

6.2.3.2.2 Ageing process of rotor cage N/A


6.2.3.2.3 Motors to be subjected to 10 direct-on-line uncoupled starts or N/A
10 locked rotor tests
6.2.3.2.4 Maintenance of terminal voltage and hydrogen concentration N/A

6.3 Luminaires
6.3.1 Mechanical tests for screw lampholders other than E10 No luminaires designed for mains supply N/A

6.3.2 Abnormal operation of luminaires with tubular fluorescent lamps

6.3.2.1 Rectification test N/A


6.3.2.2 Inoperative lamp test N/A
6.3.2.3 Power dissipation of cathodes of lamps supplied by electronic ballasts N/A

6.3.3 Sulphur dioxide test for the connection of bi-pin lamp caps to lampholders N/A

6.3.4 Vibration test for luminaires with bi-pin lamps N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 14 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

6.4 Measuring instruments and instrument transformers No measuring instruments and N/A
instrument transformers

6.5 No transformers other than N/A


Transformers other than instrument transformers instrument transformers

6.6 Secondary batteries


6.6.1 Application of tests Not apply to 5.7 N/A
Insulation resistance
6.6.2.1 Test conditions N/A
6.6.2.2 Insulation resistance N/A
6.6.3 Shock test
6.6.3.1 General N/A
6.6.3.2 Test conditions N/A
6.6.3.3 Test procedure N/A
6.6.3.4 Acceptance criteria N/A
6.6.4 Test for ventilation of battery container
6.6.4.1 Determination of the maximum hydrogen concentration within the battery N/A
container
6.6.4.2 Determination of hydrogen flow rate N/A
6.6.4.3 Test Method N/A
6.6.4.4 Test Procedure N/A
6.6.4.5 The test to be carried out at least twice N/A
6.6.4.6 Hydrogen concentration not to exceed 2 % N/A
6.7 General purpose connection and junction boxes No general purpose connection and junction N/A
boxes
6.8 Resistance heating devices and resistance heating units --

6.8.1 No resistance heating devices and resistance N/A


Type tests and additional requirements of 5.9 heating units

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 15 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

6.8.2 The tests carried out on a sample or prototype N/A

6.8.3 Verification of the electrical insulation of the sample or prototype N/A

6.8.4 Thermal stability of the insulating materials of the resistance heating device N/A

6.8.5 The test for resistance to impact shall be carried out on two new samples or N/A
prototypes with an apparatus similar to that shown in IEC 60079-0.

6.8.6 Test for cold start current N/A


6.8.7 Tests for specific forms of resistance heating devices or units N/A

6.9 Terminal insulating material tests Terminals are not included. N/A
7 ROUTINE VERIFICATIONS AND ROUTINE TESTS

7.1 Dielectric tests The products are submitted to dielectric test before Pass
delivery. Test voltage is 2500V. duration is 1min.

7.2 Dielectric tests for batteries Not required N/A


7.3 Inter-turn overvoltage test No current transformers N/A

8 EX COMPONENT CERTIFICATES
8.1 General Not an Ex component N/A
8.2 Terminals N/A
9 MARKING AND INSTRUCTIONS
9.1 General Marking See part IEC60079-0 clause 29. Pass

Rated voltage(s) or voltage range(s) (V)................................... : Powered by battery:4-6VDC N/A

Rated current (mA or A).............. : N/A


Rated power..................................: N/A

3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 16 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

Starting current ratio IA/IN................... :


N/A

Time tE.................................................................. :
N/A

Short circuit current ISC........................ : N/A

Electrical rating, lamp.................. : N/A


Lamp dimensions......................... : N/A

Rated maximum dissipated power..............................................: N/A

Permissible number of conductors..................................... : N/A

Size of conductors........................: N/A

Maximum current.......................... : N/A

Restrictions in use........................ : N/A

Characteristics of special protective devices........................ : N/A

Type of construction of cells....... : N/A


Number of cells.............................: N/A
Nominal voltage of cells...............: N/A
Rated capacity of cells.................: N/A
Duration of cell discharge............: N/A
WARNING - DO NOT CHARGE IN HAZARDOUS See the instruction N/A
AREA.............. :
Conductor range...........................: N/A
Rated voltage................................ : N/A
Operating temperature................ : N/A
9.2 Instructions for use N/A
9.2.1 Battery operated apparatus N/A
N/A
Name of manufacturer or supplier or registered trademark

Manufacturer's type identification N/A

Number of cells N/A

Nominal voltage of the battery N/A

Rated capacity N/A

Shenzhen ZCT Technology Co., Ltd.


Page 17 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

Charging instructions N/A

Safe operating conditions N/A

WARNING - REFER TO THE INSTRUCTION MANUAL FOR BATTERY N/A


CHARGING

9.2.2 Terminals N/A

Assigned torque value(s) N/A


Indication of rearrangement or adjustment to adapt to various sizes of N/A
conductors
Instructions for proper conductor installation N/A
Conductor insulation stripping requirements N/A

9.2.3 Luminaires N/A


Bi-pin luminaires N/A
Screw-cap lamps N/A
9.2.4 Motors No motors N/A

Routine maintenance and lubrication of bearings N/A

Routine testing of insulated rotor bar insulation N/A

9.3 Warning markings Warning words can be found in the instructions N/A

ANNEX A CAGE MOTORS- METHODS OF TEST AND OF CALCULATION

A.1 Temperature rise of the stator No cage motors N/A


A.2 Temperature rise of the stator and rotor windings at rated service N/A

A.3 Determination of temperature rise in stalled motors N/A

A.3.1 Ambient temperature and application of rated voltage and rated frequency N/A

A.3.2 Measurement of stator current N/A


A.3.3 Temperature rises in the rotor cage N/A

Shenzhen ZCT Technology Co., Ltd.


Page 18 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

A.3.4 Average temperature rise in the stator N/A


A.3.5 Stalled motor test N/A
A.4 Calculation of temperature rise in stalled motors N/A

A.4.1 Calculating the temperature of the short-circuited rotor N/A

A.4.2 The rate of temperature rise N/A


A.5 Determination of time tE
N/A

A.6 Motors designed for arduous starting conditions N/A

A.7 Motors forming units with converters and the associated protective devices N/A

ANNEX B TYPE TESTS FOR SPECIFIC FORMS OF RESISTANCE HEATING


DEVICES OR RESISTANCE HEATING UNITS

B.1 Resistance heating devices subjected to mechanical stresses No resistance heating devices and resistance N/A
heating units.

B.2 Resistance heating devices or units intended for immersion N/A

B.3 Resistance heating devices or units having hygroscopic insulating material N/A

B.4 Verification of limiting temperature of resistance N/A


heating devices (other than trace heaters)

B.4.1 Test procedure N/A


B.4.2 Resistance heating unit protected by a safety device in accordance to N/A
5.9.12
B.4.2.1 Safety device sensing the temperature N/A

B.4.2.2 Safety device sensing the temperature and at least one other protective N/A
parameter

B.4.2.3 Safety device sensing a parameter other than the temperature N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 19 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

B.4.3 Resistance heating unit of stabilized design N/A

B.4.4 Heating device with temperature self-limiting characteristic N/A

ANNEX H TEST PROCEDURE FOR T8, T10 AND T12 LAMPS

H.1 Asymmetric pulse test N/A


H.1.1 General No lamps N/A
H.1.2 Test procedure N/A
H.2 Asymmetric power test N/A
H.2.1 General N/A
H.2.2 Test procedure

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 20 of 20 17ZCTS0920002-3LR
EN 60079-7
Cl. Requirement – Test Result Verdict

APPENDIX A: Additional construction remarks


4.3 TABLE: clearance distance measurements

Ur.m.s. a.c. or d.c. (V) Required cl (mm) Measured cl (mm)


Clearance (cl) between circuit parts:

No greater than 6VDC 0.5 23.2


Clearance between poles of capacitance

Clearance of PCB No greater than 6VDC 0.5 (under the compound) 0.54

4.3 TABLE: clearance distance measurements


Ur.m.s. a.c. or Required dcr (mm) Measured dcr (mm)
Creepage (dcr) distance between circuit parts:
d.c. (V)

4.4 TABLE: creepage distance measurements

6.1 TABLE: dielectric strength tests


test voltage applied between: test voltage (V) breakdown Yes / No
a.c. / d.c.
Between circuit and enclosure AC500V No
Between inlet and outlet, When the power supply is cut off. AC500V No

- End of Test Report -

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com
Page 1 of 12 17ZCTS0920002-4LR
IECEx TEST REPORT EN 60079-11
Explosive atmospheres –
Part 11: Equipment protection by intrinsic safety "i"
Report Number.............................: 17ZCTS0920002-4LR
Tested by (+ signature).............. : Kevin Yang
Approved by (+ signature) ....... : King Hu
Date of issue ................................: Sept. 25, 2017
Testing laboratory
Testing Laboratory Name .........: Shenzhen ZCT Technology Co.,Ltd.
Address..........................................:
3/F., Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen,
Guangdong, China.
Applicant’s name.........................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-11:2012
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5, BAT95R1,
BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4

II M2 D Ex tD A21 T135°C

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 12
Page 2 of 12 17ZCTS0920002-4LR
Copy of marking plate

LED Explosion-proof light BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-
II M2 G Ex deia IIC T4 21, BAT95-11

II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W

No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.

Summary of testing:
Test performed in accordance with all of the clauses of according EN 60079-11

Possible test case verdicts:


– test case does not apply to the test object ...... : N/A
– test object does meet the requirement............ : P(Pass)
– test object does not meet the requirement...... : F(Fail)
Testing ..................................................................
Date of receipt of test item .................................. : Sept, 06, 2017
Date(s) of performance of test .............................. : Sept, 06, 2017 to Sept, 25, 2017

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 12
Page 3 of 12 17ZCTS0920002-4LR

General remarks:

The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.

Throughout this report a comma (point) is used as the decimal separator.

Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.

This test report includes:


Annex I: Photo documentation, 2 pages
General product information:

LED Explosion-proof light, models BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4,
BAT95R5, BAT95S7, BAT95X60, BAT95X35,
BAT9512, BAT95-21, BAT95-11

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 45 of 12
Page 4 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

1 SCOPE
2 NORMATIVE REFERENCES
3 DEFINITIONS
4 GROUPING AND CLASSIFICATION Pass

5 LEVELS OF PROTECTION AND IGNITION


COMPLIANCE
5.1 General Level of protection: ”ib” Pass

5.2, 5.3, 5.4 Level of protection Pass


5.5 Spark ignition compliance Refer to Appendix A.2 for Pass
details.
5.6 Thermal ignition compliance
5.6.1 General Refer to Appendix A.3 for Pass
details.
5.6.2 Temperature for small components Refer to Appendix A.3.1 for Pass
details.
5.6.3 Wiring within apparatus Refer to Appendix A.3.2 for Pass
details.
5.6.4 Tracks on printed circuit boards Refer to Appendix A.3.3 for Pass
details.
5.7 Simple apparatus The equipment is not a simple Pass
apparatus.
6 APPARATUS CONSTRUCTION
6.1 Enclosures Non-metallic enclosure and its
material is PC(Black).
Surface resistance test was done according to Cl. 26.13
of IEC60079-0:2007.
The enclosure has a degree of protection of IP66.

6.1.1 Apparatus complying with Table 5 It complies with Table 5. Pass


6.1.2 Apparatus complying with Annex F Annex F is not used. N/A
6.1 N/A
6.2 Facilities for connection of external circuits No facilities for connection of N/A
external circuits.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 46 of 12
Page 5 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

6.2.1 Terminals No terminals. N/A


6.2.2 Plugs and sockets No plugs or sockets. N/A
6.2.3 Determination of maximum external Not involved. N/A
inductance to resistance ratio (Lo/Ro) for resistance limited power source

6.2.4 Permanently connected cable No cable for external N/A


connection.
6.3 Separation distances Comply with the requirements. Pass
6.3.1 Separation of conductive parts The distances on the PCB of Pass
battery protection board and LED driving board were
evaluated by using image measuring instrument.

6.3.1.1 Distances according to Table 5 The battery protection board Pass


of 18650-10S9P is completely encapsulated, separation
distance through casting compound is 0.582mm, so it
complies with Table 5.

The creepage distance under


coating of LED driving board is 0.586mm, so it
complies with
Table 5.
6.3.1.2 Distances according to Annex F Annex F is not used. N/A
6.3.2 Voltage between conductive parts Correspond with the Pass
requirements of 6.3.2.
6.3.3 Clearance No insulating partitions with N/A
more than 0.9mm thickness or conforming with
10.6.3,present.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 47 of 12
Page 6 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

6.3.4 Separation distances through casting The fuses and battery Pass
compound protection board of AT-1280 are encapsulated , the
minimum separation distance betweenencapsulated
conductive components and
the free surface of the casting compound is a minimum of
1mm.

6.3.5 Separation distances through solid insulation No solid insulation. N/A


6.3.6 Composite separations No composite separations N/A
given that need evaluation.
6.3.7 Creepage distance All creepage distances are Pass
according to table 5.
6.3.8 Distance under coating The board is completely under Pass
coating.
6.3.9 Requirements for assembled printed circuit Comply with the requirements. Pass
boards
6.3.10 Separation by earth screens No earth screens. N/A
6.3.11 Internal wiring No internal wiring that needs N/A
separations.
6.3.12 Dielectric strength requirement No metallic enclosure and no N/A
necessary.
6.3.13 Relays Protection Against Polarity No relays. N/A
6.4 Reversal No diode necessary. N/A
6.5 Earth conductors, connections and terminals No earth conductors. N/A
6.6 Encapsulation The fuses and battery Pass
protection board of are completely encapsulated.
The encapsulating material is ET-5 Room Temperature
Solidification Pasty Adhesive and its operating
temperature is -25℃ ~ 145℃.

7 COMPONENTS ON WHICH INTRINSIC


SAFETY DEPENDS

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 48 of 12
Page 7 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

7.1 Rating of components Refer to Appendix A.4 for Pass


details.
7.2 Connectors for internal connections, plug-in The intrinsic safety parts have N/A
cards and components no connectors.
7.3 Fuses F1and F2, manufactured by Pass
Skytex, model are
F400mAL250VP and
F1000mAL250VP , rating are 0.4A and 1A.

7.4 Primary and secondary cells and batteries The intrinsic safety parts have N/A
no cells and batteries.
7.4.1 General The intrinsic safety parts have N/A
no cells and batteries.
7.4.2 Electrolyte leakage and ventilation The intrinsic safety parts have N/A
no cells and batteries.
7.4.3 Cell voltages The intrinsic safety parts have N/A
no cells and batteries.
7.4.4 Internal resistance of cell or battery The intrinsic safety parts have Pass
External contacts for charging batteries 7.4.9 no cells and batteries.
7.4.5 Batteries in apparatus protected by other The intrinsic safety parts have N/A
means of protection no cells and batteries.
7.4.6 Batteries used and replaced in explosive gas The intrinsic safety parts have N/A
atmospheres no cells and batteries.
7.4.7 Batteries used but not replaced in explosive The intrinsic safety parts have N/A
gas atmospheres no cells and batteries.
7.4.8 There are four series blocking N/A
diodes D1~D4(1N5400) placed in the
battery protection circuit to prevent the batteries from
delivering energy to the external contacts.

7.4.9 Battery construction The intrinsic safety parts have


no cells and batteries.
7.5 Semiconductors No semiconductors. N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 49 of 12
Page 8 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

7.5.1 Transient effects Transient effects are not N/A


expected.
7.5.2 Shunt voltage limiters No shunt voltage limiters N/A
used.
7.5.3 Series current limiters No series current limiters N/A
used.
7.6 Failure of components, connections and “ib” protection level and the Pass
separations components are
7.7 Piezo-electric No piezo-electric devices N/A
7.8 Electrochemical cells for the detection of No electrochemical cells. N/A
gases
8 INFALLIBLE COMPONENTS, INFALLIBLE
ASSEMBLIES OF COMPONENTS AND INFALLIBLE CONNECTIONS ON
WHICH INTRINSIC SAFETY DEPENDS

8.1 Mains transformers N/A


8.1.1 Protective measures No transformers. N/A
8.1.2 Transformer construction No transformers. N/A
8.1.3 Transformer type tests No transformers. N/A
8.1.4 Routine test of mains transformers No transformers. N/A
8.2 Transformers other than mains transformers No transformers. N/A
8.3 Infallible windings Not involved. N/A
8.3.1 Damping windings The current-limiting resistor N/A
R6 and R7is rated in
accordance with the
requirements of 7.1.
8.3.2 Inductors made by insulated conductors N/A
Current-limiting resistors
8.4 Current-limiting resistors The current-limiting resistor Pass
R6 and R7 is rated in accordance with the requirement
of 7.1

8.5 General Blocking capacitors No blocking capacitors. N/A


8.6 Shunt safety assemblies Not involved. N/A
8.6.1 General Not involved. N/A
8.6.2 Safety shunts N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 50 of 12
Page 9 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

8.6.3 Shunt voltage limiters N/A


8.7 Wiring, printed circuit board tracks, and N/A
connections
8.8 Galvanically separating components No galvanic separating N/A
components.
8.8.1 General N/A
8.8.2 Isolating components between intrinsically N/A
safe and non-intrinsically safe circuits
8.8.3 Isolating components between separate N/A
intrinsically safe circuits
9 Diode Safety Barries N/A
9.1 General No diode safety barrier. N/A
9.2 Mounting No diode safety barrier. N/A
9.2.1 Construction No diode safety barrier. N/A
9.2.2 Facilities for connection to earth No diode safety barrier. N/A
9.2.3 10 Protection of components TYPE No diode safety barrier. N/A
VERIFICATIONS AND TYPE TESTS
10.1 General Refer to Appendix A.2 for N/A
details.
10.1.1 Spark ignition test The circuit meets the N/A
requirements of the curves Fig.A1to A6, so it is free for
spark test.

10.1.2 Spark test apparatus N/A


10.1.3, Test gas mixtures and spark test apparatus N/A
10.1.3.1, calibration current
10.1.3.2
10.1.4, Tests with the spark test apparatus – circuit N/A
10.1.4.1, test, safety factors
10.1.4.2
10.1.5 Testing considerations
10.1.5.1 General Refer to Appendix A.2.4 for N/A
details.
10.1.5.2 Circuits with both inductance and capacitance Refer to Appendix A.2.5 for N/A
details.
10.1.5.3 Results of spark test N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 51 of 12
Page 10 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

10.1.5.4 Circuits using shunt short-circuit (crowbar) N/A


protection
10.2 Temperature tests The tests were carried out in Pass
accordance with 10.2 and the result complies with T4.See
annex B.1.

10.3 Dielectric strength tests No dielectric strength tests N/A


necessary.
10.4 Determination of parameters of loosely No loosely specified N/A
specified components components.
10.5 Tests for cells and batteries The intrinsic safety parts have
no cells and batteries.
10.5.1 General The intrinsic safety parts have N/A
no cells and batteries.
10.5.2 Electrolyte leakage test for cells and batteries N/A
10.5.3 Spark ignition and surface temperature of cells N/A
and batteries
10.5.4 Battery container pressure tests N/A
10.6 Mechanical tests There is no free surface of N/A
casting compound.
10.6.1 Casting compound There is no free surface of N/A
casting compound
10.6.2 Sealing of components before encapsulation Encapsulation can not enter N/A
the interior of component and affect safety.

10.6.3 Partitions No partitions. N/A


10.7 Tests for apparatus containing piezoelectric No piezoelectric devices. N/A
devices
10.8 Type tests for diode safety barriers and safety No diode safety barriers.
shunts
10.9 Cable pull test No cable. N/A
10.10 Transformer tests No transformer. N/A
11 ROUTINE VERIFICATIONS AND TESTS N/A
11.1 Completed barriers N/A
11.1 .1 Routine tests for diode safety barriers N/A
11.1.2 Diodes for 2-diode “ia” barriers N/A

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 52 of 12
Page 11 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

11.2 Routine tests for infallible transformers N/A


12 MARKING
12.1 General Ex e ib II C T4 Gb Pass
12.2 Marking of connection facilities No connection facilities. N/A
12.3 Warning markings N/A
13 DOCUMENTATION The documentation is Pass
complete, includes General assembly drawing, schematic
diagram and PCB diagram, material quality report of ET-
5 Room Temperature
Solidification Pasty Adhesive and Operating instruction
of encapsulation etc.

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 53 of 12
Page 12 of 12 17ZCTS0920002-4LR
EN 60079-11
Cl. Requirement – Test Result Verdict

APPENDIX A: Additional construction remarks


4.3 TABLE: clearance distance measurements

Ur.m.s. a.c. or d.c. (V) Required cl (mm) Measured cl (mm)


Clearance (cl) between circuit parts:

No greater than 6VDC 0.5 23.2


Clearance between poles of capacitance

Clearance of PCB No greater than 6VDC 0.5 (under the compound) 0.54

4.3 TABLE: clearance distance measurements


Ur.m.s. a.c. or Required dcr (mm) Measured dcr (mm)
Creepage (dcr) distance between circuit parts:
d.c. (V)

4.4 TABLE: creepage distance measurements

6.1 TABLE: dielectric strength tests


test voltage applied between: test voltage (V) breakdown Yes / No
a.c. / d.c.
Between circuit and enclosure AC500V No
Between inlet and outlet, When the power supply is cut off. AC500V No

- End of Test Report -

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 54 of 12
Page 1 of 5 17ZCTS0920002-5LR
IECEx TEST REPORT EN 60079-31
Explosive atmospheres –
Part 31: Equipment dust ignition protection by enclosure "t"
Report Number.............................: 17ZCTS0920002-5LR
Tested by (+ signature).............. : Kevin Yang
Approved by (+ signature) ....... : King Hu
Date of issue ................................: Sept. 25, 2017
Testing laboratory
Testing Laboratory Name .........: Shenzhen ZCT Technology Co.,Ltd.
Address..........................................: 3/F., Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen,
Guangdong, China.
Applicant’s name.........................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Manufactuer’s name................... : Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Factory’s name.............................: Suzhou Zhaochang Electronic Technology Co.,Ltd.

Address..........................................: No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China. 215000.
Standard.........................................: EN 60079-31:2014
Test procedure............................. : CE
Non-standard test method........ : N/A
Test item description....................: LED Explosion-proof light
Trade Mark.......................................:
Model/Type reference................... : BAT95-T
BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,
BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5,
BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-21,
BAT95-11
Ratings............................................. :
II M2 G Ex deia IIC T4

II M2 D Ex tD A21 T135°C

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 5
Page 2 of 5 17ZCTS0920002-5LR
Copy of marking plate

LED Explosion-proof light BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5,

II M2 G Ex deia IIC T4 BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7, BAT95X60, BAT95X35, BAT9512, BAT95-

21, BAT95-11
II M2 D Ex tD A21 T135°C
Model: BAT95-T
Batch No.:
Using ambient temperature:-15~40C 86-265VAC 50/60Hz 250W

No.98,Yinxin Road, Wuzhong District, Suzhou city, Jiangsu Province, P.R. China.
215000.

Summary of testing:
Test performed in accordance with all of the clauses of according EN 60079-31

Possible test case verdicts:


– test case does not apply to the test object ...... : N/A
– test object does meet the requirement............ : P(Pass)
– test object does not meet the requirement...... : F(Fail)
Testing ..................................................................
Date of receipt of test item .................................. : Sept, 06, 2017
Date(s) of performance of test .............................. : Sept, 06, 2017 to Sept, 25, 2017

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com Page 2 of 5
Page 3 of 5 17ZCTS0920002-5LR

General remarks:

The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

"(see Enclosure #)" refers to additional information appended to the report. "(see appended table)"
refers to a table appended to the report.

Throughout this report a comma (point) is used as the decimal separator.

Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.

This test report includes:


Annex I: Photo documentation, 2 pages
General product information:

LED Explosion-proof light, models BAT95-T


BAT95-G, BAT95-N, BAT95-B, BAT95-C, BAT95R5, BAT95R1, BAT95R2, BAT95R3, BAT95R4, BAT95R5, BAT95S7,
BAT95X60, BAT95X35, BAT9512, BAT95-21, BAT95-11

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 57 of 5
Page 4 of 5 17ZCTS0920002-5LR
EN 60079-31
Cl. Requirement – Test Result Verdict

1 SCOPE
2 NORMATIVE REFERENCES
3 TERMS AND DEFINITIONS
4 LEVEL OF PROTECTION Refer to test report Pass
IEC60079-0
4.1 General Refer to test report Pass
IEC60079-0
4.2 Thermal protection The protection lever is “Db”. N/A
4.2.1 Additional requirements for level of protection
N/A
“ta”
4.2.1.1 General The protection lever is “Db”. N/A
4.2.1.2 Protective devices N/A
4.2.1.3 Temperature limitation N/A
5 Construction Pass
5.1 Joint
5.1.1 The rubber rings are provided Pass
General
at the joints.
5.1.2 Refer to test report Pass
Gaskets and seals
IEC60079-0 clause 6.5.
5.1.3 No cemented joints. Operating N/A
Cemented joints rods, spindles and shafts through
the
5.1.4 Operating rods, spindles and shafts enclosure are not included. N/A
5.1 5 Joints CONSTRUCTION Pass
5.1.5 Windows N/A
5.1.5.1 Windows employing a cemented joint cemented joint is not included. N/A
Windows made of glass Pass
employ a gasket joint.
5.1.5.2 Windows employing a gasket joints
Refer to test report
IEC60079-0
5.2 Cable glands and threaded entrie Cable glands are not included. N/A
5.2.1 Cable glands
Thread entries are not
5.2.2 Threaded entries N/A
included.
6 VERIFICATION AND TESTS
6.1 Type tests

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 58 of 5
Page 5 of 5 17ZCTS0920002-5LR
EN 60079-31
Cl. Requirement – Test Result Verdict

Refer to Cl.26.8, Cl.26.9 in Pass


Type tests for dust exclusion by enclosures
6.1.1 test report IEC60079-0.
Thermal tests Refer to test report
6.1.2 Pass
IEC60079-0 cl. 26.5.
6.1.3 Pressure test The samples were submitted Pass
to gas pressure test.
Test pressure: 2KPa. Duration: 61s,
No damage to enclosure or permanent deformation
affecting the explosion-proof performance has been
found. After this test, the IP test was carried out on the
same samples.

6.2 Routine tests Reference only


6.2 7 MARKING Refer to test report Pass
IEC60079-0
Additional Narrative Remarks (as deemed
Pass
applicable):

- End of Test Report -

Shenzhen ZCT Technology Co., Ltd.


3F, 5th Building, Hongsheng Industrial Zone, No.4336 Bao'an Road, Bao'an District, Shenzhen, China Tel: 400-805-1899;
Fax:86-755-23702323; http://www.renzhengjiance.com

Page 59 of 5
BAT95-T SERIES LED EX-PROOF LIGHT

Product Features

High pressure die casting aluminum housing


The surface is sprayed with high pressure static electricity High
explosion-proof grade, light and beautiful appearance

Professional cooling design structure,long life of LED lamps

Special tempered glass, impact resistance, high strength

High energy saving LED light source, imported light source, green, low
energy consumption, long life, free maintenance

Technical Parameters

Product Power 50~300W


Input Voltage 85-265V
Frequency 50~60Hz
Power Factor 0.95
LED Chip Brand Cree
Ex-mark Ex de II C T6 Gb
IP Rating IP65/IP66
Product Size ( mm ) Protection Grade WF2
Model Power H L
CRI Ra > 85
W
BAT95-T 50/80/100W 166 330 255 Light Efficiency ≥120lm/W
BAT95-T 120/150/200W 166 446 306 Ambient Temp -55℃~+60℃
BAT95-T 240/300W 200 520 360 Service Life >50000H

http://www.sinozoc-ex.com/en/ 02
BAT95R2 SERIES LED EX-PROOF LIGHT

Product Features

High pressure die casting aluminum housing


The surface is sprayed with high pressure static electricity High
explosion-proof grade, light and beautiful appearance

Professional cooling design structure , Long life of LED lamps

Special tempered glass, impact resistance, high strength

High energy saving LED light source, imported light source, green, low
energy consumption, long life, free maintenance

Technical Parameters

Product Power 30~200W


Input Voltage 85-265V
Frequency 50~60Hz
Power Factor 0.95
LED Chip Brand Lumileds
Ex-mark Ex d e II C T6 Gb
IP Rating IP65/IP66
Product Size ( mm ) Protection Grade WF2
Model Power Weight ( kg
H L W
) CRI Ra > 85
BAT95R2 30/40/50W 468 190 62 5.0 Light Efficiency ≥120lm/W
BAT95R2 60/70/80/100W 545 244 70 7.0 Ambient Temp -55℃~+60℃
BAT95R2 120/150W 595 244 70 9.0 Service Life >50000H
BAT95R2 180/200W 655 280 70 11.0

http://www.sinozoc-ex.com/en/ 04
BAT95-G SERIES LED EX-PROOF LIGHT

Product Features

The light transmissive surface is made of 10mm thick high strength


tempered glass;
The aluminum substrate adopts imported insulation layer from
Taiwan, and the thermal conductivity is higher;
The lamp beads are made of American CREE chip;
Built-in high performance waterproof driver power supply, with
lighting protection, surge protection, short circuit protection, over
voltage protection, over current protection;
The diameter of the outlet is G3/4, and the wire sleeve is made of
high temperature resistant silicone material. It will not deform after
long-term compression, and will not harden, ensuring long-lasting
effective flameproof performance.

Technical Parameters

Product Power 30~200W


Input Voltage 85-265V
Frequency 50~60Hz
Power Factor 0.95
LED Chip Brand Cree
Ex-mark Ex de IIC T6 Gb
IP Rating IP65/IP66
Protection Grade WF2 Product Size ( mm )
Model Power
H L W Weight ( kg
CRI Ra > 85

Light Efficiency ≥120lm/W BAT95-G 30/40/50W 270 220 220 5.5

Ambient Temp -55℃~+60℃ BAT95-G 80/100W 285 260 260 6.6


BAT95-G 120/150W 320 310 310 9.4
Service Life >50000H
BAT95-G 200W 330 310 310 10.8

07 http://www.sinozoc-ex.com/en/
BGS-GH SERIES LED EX-PROOF TUBE

Product Features

Stripe light cover is with high light transmittance, not dazzling, the
light is even and soft downy ;
Flame retardant light feet is made of high quality flame retardant
materials, with good heat resistance ;
Highlight energy-saving LED light source, green environmental
protection, with low energy consumption, maintenance
free and other advantages ;
The bottom shell is equipped with a fixed light cover buckle, with
high strength and not easy to damage, so that the light can
be installed quickly.

Technical Parameters

Product Power 2X9W/2X18W

Input Voltage 85-265V


Frequency 50~60Hz
Power Factor 0.95
LED Chip Brand Lumileds
Ex-mark Exde IIB T6
IP Rating IP65
Protection Grade WF2
CRI Ra > 85
Light Efficiency ≥100lm/W Power Product Size ( mm )
Model Weight ( kg
H L W
Ambient Temp -55℃~+60℃ )
BGS-GH 2x9W 120 770 208 3.9
Service Life >50000H
BGS-GH 2x18W 120 1370 160 7.6
Interface specification G3/4

Cable specification 8mm~12


mm

19 http://www.sinozoc-ex.com/en/
LED EMERGENCY EXIT LIGHT
SL-YJM-1

Description:
This product use high quality aluminum shell and glass board as the main material,simple looking design,with durable long life span LED as light
source,it can be used in building,hospital,supermarket and other public places

Electrical Specification
>Input Voltage: AC220/ 50-60Hz
>Power: 3W
>Product Size: 355*22*145mm
>Light Source: LED
>Back Up time: 90/120/180minutes
>Battery Type: Nickel-cadmium
>Battery Voltage: 1.2V
>Material: Aluminum+Glass
>Life Span: 50,000 Hours
>Installation Way: Wall Mounted/Hanging
>Net Weight: 0.6kg
>Gross Weight: 0.65kg
>Package size: 590*380*190mm (20pcs/box)
>Weight: 12KG/ctn
>IP Grade: IP20
Installation Information:
1. First set up accessories and fittings of the light
2. Cut off the power before installation
Tri-proof light manual
I. Application

Applicable to various types of office buildings, department stores, dust-free workshop, underground parking and
other places of lighting.

II. Product features


1. Energy saving and environmental protection, no ultraviolet, infrared and mercury pollution
2. High quality ABS+ PC, soft light is not dazzling
3. High transmittance stripe mask, uniform luminous surface, no dark spots
Power 18W, 2x18W
4. Light appearance, new style, easy to install and transport light green
Surface color
Product size L1260×W115×H90mm
III. Product
Light material specification ABS , PC
Beam angle 157°
Operating temperature -20 ~ +45℃
Storage temperature -30 ~ +65℃
IP rating IP54

IV. Optical and thermal parameters

Light distribution curve (LED tube)


V. Packaging, transportation and storage requirements
1.Each product is packed in an independent inner box, and the outer carton is packed with 5 layers of kraft paper
2. Labels of light can be customized according to customer requirements
3. Before delivery, the packing box should be sealed, handled with care
4.Storage requirements: moistureproof, dustproof, pressure proof, fall proof, acid and alkali proof, avoid direct
sunlight and condensation
5.Storage life: 1 year. If the storage life is exceeded, the light must be rechecked (electrical performance)
before use

VI. Installation method

6.Take out the accessories from the parts package, fix the expansion screw on the position to be installed, and
install the waterproof connector at the inlet;
7.Fix the stainless steel bracket with a screw of Φ4 *30mm, the screw must be tightened, the three anti-lamp buckle
into the stainless steel bracket installed inside;
8.The lamp input is 220V, through the waterproof connector, the brown wire is connected to the power line, the
blue wire is connected to the power line zero, insert the terminal and tighten, and then tighten the waterproof
connector until the sheath can not be pulled out;
9. Install the LED tube into the lamp holder and rotate it face down;
10.When the power supply voltage is within the rated working range of the lamp, turn on the switch and light the
lamp to observe whether the lighting process is normal.

VII. Attention
11.The selection of LED lamp tube according to the actual wiring situation selection, and must be matched with
the wiring scheme, to avoid short circuit.
12.Please turn off the lamp holder power before replacing LED lamps.
13.Can not be used in flammable, explosive, high temperature and corrosive places.
14.When the light is out of order, it should be repaired by professional personnel.

VIII. The following conditions are not covered by the warranty


15.Damage caused by repair and modification not approved by the manufacturer
16.Damage caused by faulty wiring, careless use or accidents
17.Force majeure, such as natural disasters, abnormal voltage and other causes of damage
DOWNLIGHT LED, 11.6W, 230VAC, 60Hz