Introduction To Analytical Chemistry
Introduction To Analytical Chemistry
Introduction To Analytical Chemistry
Analytical Chemistry
Chapter 6
Titrations: Taking Advantage of
Stoichiometric Reactions
4-2
Copyright©2011 Cengage Learning
Volumetric titrimetry involves measuring
the volume of solution of known
concentration that is needed to react
essentially completely with the analyte.
• Gravimetric Titrimetry differs from volumetric
titrimetry in that the amount of solution added
to complete the reaction is measured by mass
rather than by volume.
4-3
Copyright©2011 Cengage Learning
Titrations: Taking Advantage
of Stoichiometric Reactions
• Coulometric titrimetry is a type of titrimetry in
which the quantity of charge in coulombs
required to complete a reaction with the analyte
is measured.
Coulometric titration is an absolute
determination technique in which the mass of a
given substance is determined by measuring the
quantity of electricity required to electrolyze that
substance.
4-4
Copyright©2011 Cengage Learning
6A-1 Defining Some Terms
• A standard solution is a reagent of known
concentration that is used in a titrimetric analysis.
• Titration is a process in which a standard reagent
is added to a solution of an analyte until the
reaction between the analyte and reagent is
judged to be complete.
(Lesson 1 Principles of Volumetric Analysis )
4-5
Copyright©2011 Cengage Learning
6A-1 Defining Some Terms
• Back-titration is a process in which the excess
of a standard solution used to consume an
analyte is determined by titration with a
second standard solution.
• Back-titrations are often required when the
rate of reaction between the analyte and
reagent is slow or when the standard solution
lacks stability.
4-6
Copyright©2011 Cengage Learning
6A-2 Equivalence Points and
End Points
• The equivalence point of a titration cannot be
determined experimentally.
• The equivalence point is the point in a titration
when the amount of added standard reagent is
equivalent to the amount of analyte.
• The difference in volume or mass between the
equivalence point and the end point is the
titration error.
4-7
Copyright©2011 Cengage Learning
6A-2 Equivalence Points and
End Points
• Indicators are often added to the analyte
solution to give an observable physical change
(the end point) at or near the equivalence
point.
• The end point is the point in a titration when a
physical change occurs that is associated with
the condition of chemical equivalence.
4-8
Copyright©2011 Cengage Learning
6A-3 Primary Standards
• A primary standard is a highly purified
compound that serves as a reference material
in all volumetric and mass titrimetric methods.
• Important requirements for a primary
standard are
− 1.High purity (established methods for confirming
purity should be available)
− 2. Atmospheric stability
4-9
Copyright©2011 Cengage Learning
6A-3 Primary Standards
− 3. Absence of hydrate water so that the
composition of the solid does not change
with variations in relative humidity
− 4. Ready availability at modest cost
− 5. Reasonable solubility in the titration medium
− 6. Reasonably large molar mass so that the
relative error associated with weighing the
standard is minimized
4-10
Copyright©2011 Cengage Learning
6A-3 Primary Standards
• A secondary standard is a compound whose
purity has been established by chemical
analysis and that serves as the reference
material for a titrimetric method of analysis.
4-11
Copyright©2011 Cengage Learning
6B-1 Desirable Properties of Standard
Solutions
• The ideal standard solution for a titrimetric
method will
− 1. Be sufficiently stable so that it is only necessary to
determine its concentration once
− 2. React rapidly with the analyte so that the time required
between additions of reagent is minimized
− 3. React completely with the analyte so that satisfactory
end points are realized
− 4. Undergo a selective reaction with the analyte that can
be described by a balanced equation
4-12
Copyright©2011 Cengage Learning
6B-2 Establishing the Concentration
of Standard Solutions
• Two basic methods are used to establish the
concentration of such solutions.
• The first is the direct method in which a
carefully weighed quantity of a primary
standard is dissolved in a suitable solvent and
diluted to a known volume in a volumetric
flask.
4-13
Copyright©2011 Cengage Learning
6B-2 Establishing the Concentration
of Standard Solutions
• The second is by standardization in which the
titrant to be standardized is used to titrate (1)
a weighed quantity of a primary standard, (2)
a weighed quantity of a secondary standard,
or (3) a measured volume of another standard
solution.
4-14
Copyright©2011 Cengage Learning
6B-2 Establishing the Concentration
of Standard Solutions
• A titrant that is standardized against a secondary
standard or against another standard solution is
sometimes referred to as a secondary standard
solution. The concentration of a secondary standard
solution is subject to a larger uncertainty than that
for a primary standard solution. Thus, if there is a
choice, solutions are best prepared by the direct
method. On the other hand, many reagents lack the
properties required for a primary standard and
therefore require standardization
4-15
Copyright©2011 Cengage Learning
6B-3 Expressing the Concentration
of Standard Solutions
• The concentrations of standard solutions are
generally expressed in units of either molarity
c or normality cN .
4-16
Copyright©2011 Cengage Learning
6C-1 Some Useful Algebraic Relationships
(6-1)
(6-2)
4-17
Copyright©2011 Cengage Learning
6C VOLUMETRIC CALCULATIONS
(6-3)
(6-4)
4-18
Copyright©2011 Cengage Learning
6C-3 Treating Titration Data
• Calculating Molarities from Standardization
Data
4-19
Copyright©2011 Cengage Learning
6C-3 Treating Titration Data
• Calculating the Quantity of Analyte from
Titration Data
– Titration curves are plots of a concentration-
related variable as a function of reagent volume.
4-20
Copyright©2011 Cengage Learning
Example 6-6
• A 0.8040-g sample of an iron ore is dissolved in acid.
The iron is then reduced to Fe²⁺ and titrated with
47.22 mL of 0.02242 M KMnO₄ solution. Calculate
the results of this analysis in terms of (a) % Fe
(55.847 g/mol) and (b) % Fe₃O₄(231.54 g/mol). The
reaction of the analyte with the reagent is described
by the equation
4-21
Copyright©2011 Cengage Learning
Example 6-6
4-22
Copyright©2011 Cengage Learning
Example 6-6
• The percent Fe²⁺ is
4-23
Copyright©2011 Cengage Learning
Example 6-6
• Therefore,
• and
4-24
Copyright©2011 Cengage Learning
Example 6-6
• As in part (a),
4-25
Copyright©2011 Cengage Learning
Calculations Involved during Titration
1.Recall what you have learned in Stoichiometry and use the following guide:
4-26
Copyright©2011 Cengage Learning
Example 6-6
Titration data: 47.22 mL of 0.02242 M KMnO4
Wt. sample = 0.8040
g Fe = 47.22 mL KMnO4 x 0.02242 mmol/mL KMnO4
x 5mmol Fe___ x 55.847 g Fe x 1 mol____
1mmol KMnO4 1 mol 1000 mmol
g Fe = 0.29562 g
% Fe = 0.29562 g x 100 % = 36.77 %
0.8040 g
4-27
Copyright©2011 Cengage Learning
Calculations Involved during Titration
4-28
Copyright©2011 Cengage Learning
6D Titration Curves
• The two most widely used end points involve
(1) changes in color due to the reagent, the
analyte, or an indicator and (2) a change in
potential of an electrode that responds to the
concentration of the reagent or the analyte.
4-29
Copyright©2011 Cengage Learning
Figure 6-1
Figure 6-1 Two types of titration
curves.
4-30
Copyright©2011 Cengage Learning
6D-1 Types of Titration Curves
• A sigmoidal curve,important observations are
confined to a small region (typically ± 0.1 to
± 0.5 mL) surrounding the equivalence point.
• Linear segment curve, measurements are
made on both sides of but well away from the
equivalence point. Measurements near
equivalence are avoided.
4-31
Copyright©2011 Cengage Learning
Figure 6-2
Figure 6-2
Titration curves
of pH and pOH
versus volume
of base for the
titration of
0.1000 M HCl
with 0.1000 M
NaOH.
4-32
Copyright©2011 Cengage Learning
Types of Volumetric Titrimetry
4-33
Copyright©2011 Cengage Learning
Types of Volumetric Titrimetry
2. Oxidation-Reduction Methods
A reducing substance is titrated with a standard solution of an
oxidizing agent, or an oxidizing substance is titrated with a
standard solution of a reducing agent. (Permanganimetry;
Iodimetry/Iodometry; Dichromate Process; Ceric Process)
3. Precipitation Methods
A substance is titrated by precipitating it with a standard
solution of a precipitating agent.
4. Complex-ion Formation Methods
A substance is titrated with a standard reagent to the formation
of a complex ion.
4-34
Copyright©2011 Cengage Learning
Lesson 2 Neutralization Titration
• An acid-base titration is used to determine the unknown
concentration of an acid or base by neutralizing it with an acid or
base of known concentration (standard solutions).
4-35
Copyright©2011 Cengage Learning
Neutralization Titration
Base solutions are commonly prepared from
NaOH
KOH.
Ba(OH)2
•The concentrations of these solutions must be established by
standardization. Weak acids and weak bases are never used as
standard reagents because they react incompletely with analytes.
4-36
Copyright©2011 Cengage Learning
Neutralization Titration
• Standardization is the process of determining the exact
concentration of a solution by reacting it with a known
quantity of a primary or a secondary standard substance. The
primary standards for the standardization of the prepared acid
solutions are
sodium carbonate (Na2CO3).
tris-(hydroxymethyl)aminomethane (HOCH2)3CNH2 also
known as TRIS or THAM
sodium tetraborate decahydrate Na2B4O7.10H2O.
4-37
Copyright©2011 Cengage Learning
Neutralization Titration
• For standardization of the base solutions, the primary
standards are
potassium hydrogen phthalate KHC8H4O4
benzoic acid
potassium hydrogen iodate, KH(IO3)2
4-38
Copyright©2011 Cengage Learning
Neutralization Titration
Types of Acid-Base titrations
4-39
Copyright©2011 Cengage Learning
Neutralization Titration
• Acid-base indicators are substances which change colour or
develop turbidity at a certain pH. They locate equivalence
point and also measure pH. They are themselves acids or bases
and are soluble, stable and show strong colour changes. They
are organic in nature.
For additional information on titration curves and choice of indicators for specific type
of titration, please read
• https://byjus.com/chemistry/acid-base-titration/
•
https://courses.lumenlearning.com/boundless-chemistry/chapter/acid-base-titrati
ons/
4-40
Copyright©2011 Cengage Learning
Sample Problem
4-41
Copyright©2011 Cengage Learning
Sample Problem
4-42
Copyright©2011 Cengage Learning
4-43
Copyright©2011 Cengage Learning
4-44
Copyright©2011 Cengage Learning
Example 6-6
Titration data: 47.22 mL of 0.02242 M KMnO4
Wt. sample = 0.8040
Calculate % Fe
From the formula N = n x M, where n = no of electrons lost
N = 5 x 0.02242 M KMnO4 = 0.1121 N
% Fe = V KMnO4 x N KMnO4 x MEW Fe x 100 %
wt of sample
4-45
Copyright©2011 Cengage Learning
Lesson 3 Reduction-Oxidation Titration
4-46
Copyright©2011 Cengage Learning
Selecting and Standardizing a Titrant
4-47
Copyright©2011 Cengage Learning
Selecting and Standardizing a Titrant
4-48
Copyright©2011 Cengage Learning
Adjusting the Titrand's Oxidation State
• The titrand initially must be present in a single oxidation state.
4-49
Copyright©2011 Cengage Learning
Adjusting the Titrand's Oxidation State
A metal that is easy to oxidize—such as Zn, Al, and Ag—
can serve as an auxiliary reducing agent.
4-50
Copyright©2011 Cengage Learning
A. Permanganimetry
4-51
Copyright©2011 Cengage Learning
A. Permanganimetry
4-52
Copyright©2011 Cengage Learning
B. Ceric Process/Titration
4-53
Copyright©2011 Cengage Learning
B. Ceric Process/Titration
4-54
Copyright©2011 Cengage Learning
C. Dichromate Process/Titration
• Potassium dichromate is a relatively strong oxidizing agent
whose principal advantages are its availability as a primary
standard and its long term stability when in solution. It is not,
however, as strong an oxidizing agent as MnO4− or Ce4+, which
makes it less useful when the titrand is a weak reducing agent.
4-55
Copyright©2011 Cengage Learning
C. Dichromate Process/Titration
4-56
Copyright©2011 Cengage Learning
D. Iodimetry/Iodometry
• Iodine is another important oxidizing titrant. Because it is a
weaker oxidizing agent than MnO4−, Ce4+, and Cr2O72−, it is
useful only when the titrand is a stronger reducing agent.
4-57
Copyright©2011 Cengage Learning
D. Iodimetry/Iodometry
4-58
Copyright©2011 Cengage Learning
D. Iodimetry/Iodometry
• For additional information on titration curves for redox titration, choice of indicator
4-60
Copyright©2011 Cengage Learning
Sample Problem
4-61
Copyright©2011 Cengage Learning
Sample Problem
4-62
Copyright©2011 Cengage Learning
Lesson 4 Precipitation Titrations
Precipitation Titrations
https://www.youtube.com/watch?v=rijEMcWsI9s
4-63
Copyright©2011 Cengage Learning
Lesson 5 Complexation Titration/Complexometry
4-64
Copyright©2011 Cengage Learning
THE END
4-65
Copyright©2011 Cengage Learning