Answers For Power & Distribution
Answers For Power & Distribution
Answers For Power & Distribution
HISTORICAL BACKGROUND
1979 EGEMAC has been established with the
technical cooperation with Siemens Germany
in compliance with the joint investment law
no.230.
2
HISTORICAL BACKGROUND
2005 EGEMAC has started a license with ALSTOM
in the High Voltage Market. (Disconnectors
and Circuit Breakers 66 & 220KV).
3
HISTORICAL BACKGROUND
2009 EGEMAC has established a Joint Venture with
XD the leading manufacturer of GIS
Substations in China to build a factory of
276,000 square meters in order to increase our
market share in the local High Voltage
substations. The JV company name is XD
EGEMAC.
4
HISTORICAL BACKGROUND
2014 EGEMAC has established a Joint Venture
with CHINT the leading manufacturer of Low
Voltage Switchboards in China. The Factory
is to be set up in 6th of October and will start
production by the end of 2016.
5
FINANCIAL FIGURES
Capital/ Million
250
200
150 Capital
250
100
50 60
30
5.5
0
1979 1987 2003 2004
6
SALES STATISTICS
Total Sales/ M
1200
1200
1000 900
800
600
296.2 338.4
400 260.8
227.3
142.9
200
0
2010 2011 2012 2013 2014 2015 2016
7
COMPANY FOUNDERS
Holding Kahromika
Compan 5%
y for ELMACO
Construc 5%
tion & Siemen
Develop
ment s
25% 3%
Egyptia
n
Electric
ity
Holdin
g
Compa
ny
62%
8
COMPANY
CONTRIBUTIONS
9
COMPANY CONTRIBUTIONS
No. Companies Percentages EGP
10
ISO CERTIFICATES
11
COMPANY STRUCTURE
Chairman and Managing
Director
Managing Director
for Technical
Affairs
Warehouse
Department
12
COMPANY STRUCTURE
14
PRODUCT PORTFOLIO
MEDIUM VOLTAGE PRODUCTS
SWITCHGEARS 12 & 24 KV
15
PRODUCT PORTFOLIO
MEDIUM VOLTAGE PRODUCTS
COMPACT SUBSTATION
16
PRODUCT PORTFOLIO
MEDIUM VOLTAGE PRODUCTS
17
EGEMAC MAP
18
MEDIUM VOLTAGE
SWITCHGEAR
PIX
Name Schneider
Electric
PIX Standard 12 - 24 KV
Metal-Clad
Type compartmented
Cassette type
HVX
Circuit Breaker
Schneider
IEC Standard 62271-200
PIX Metal-clad Switch-gear is both
flexible and adaptable with wide
range of ratings and options. 19
MEDIUM VOLTAGE
SWITCHGEAR
PIX
Name Schneider
Electric
Compartment Description
Circuit Breaker
Green
Compartment
Cable
Yellow
Compartment
Bus-bar
Red
Compartment
21
MEDIUM VOLTAGE
SWITCHGEAR
Simoprime
Name
Siemens
Simoprime 12 - 24 KV
Metal-Clad
Type compartmented
ROF Type
Circuit Breaker Sion 3AH5
IEC Standard 62271-200
Simoprime Metal-clad Switch-gear is
both flexible and adaptable with wide
range of ratings and options.
22
MEDIUM VOLTAGE
SWITCHGEAR
Technical specifications (Simoprime)
Rated Voltage KV 12 17.5 24
Rated Current Up to A 3150 2500 2500
Rated Power Frequency withstand Voltage KV 28 38 50
Rated Lightning impulse withstand Voltage KV 75 95 125
Rated Short time withstand Current/ 3s Up to KA 31.5 25 25
Internal arc specification Up to KA 31.5 25 25
Rated frequency Hz 50/60
Degree of protection IP 3X or 4X
IEC Standard 62271-200
Dimensions depends on the rated Voltage and Current.
23
EGEMAC MAP
24
RING MAIN UNIT
RMU - 8AS
Name
Siemens
25
RING MAIN UNIT
RMU - AEG
Name
ABB
26
RING MAIN UNIT
RMU - ELKO
Name
SF6
Standard Equipment:
RMU - ELKO
Name
SF6
Optional Equipment:
• Geared motor
• Earth Fault Indicator
• Remote Opening & Closing operation
with cable.
28
RING MAIN UNIT
RMU - ELKO
Name
SF6
Rated
KV 12 24
Voltage
Rated
Current A 630 630
(Cable LBS)
Rated
Current A 400 400
(Fuse LBS)
Short time
withstand KA 25 25
Current
Max Rated
s 1 1 29
Duration
EGEMAC MAP
30
COMPACT SUBSTATION
Compact Substation
8FJ
Standard Equipment
31
COMPACT SUBSTATION
Compact Substation
8FJ
Standard Equipment
32
COMPACT SUBSTATION
Compact Substation
8FJ
Standard Equipment
33
COMPACT SUBSTATION
Compact Substation
8FJ
Standard Equipment
34
COMPACT SUBSTATION
Optional Equipment
Compact Substation 8FJ
Interruption
Air - type SF6 - type
Medium
Painting Electrostatic Painting Stone Painting
Low Voltage Circuit breaker Switch-Fuse
Transformer Oil type Dry type
35
COMPACT SUBSTATION
Interruption Medium
Compact Substation 8FJ
Air - type SF6 - type
36
COMPACT SUBSTATION
Low Voltage
Compact Substation 8FJ
Circuit breakers Switch-Fuse
37
COMPACT SUBSTATION
Painting
Compact Substation 8FJ
Electrostatic Painting Stone Painting
38
EGEMAC MAP
39
MEASUREMENT
TRANSFORMERS FACTORY
40
MEASUREMENT
TRANSFORMERS FACTORY
41
MEASUREMENT
TRANSFORMERS FACTORY
Current transformers Description
Burden Up to 60VA
42
MEASUREMENT
TRANSFORMERS FACTORY
Burden Up to 60VA
Accuracy 0.5P15
43
MEASUREMENT
TRANSFORMERS FACTORY
Classes Of Current
Description
Transformer
ADA 12
Current Transformer
ADA 24
12 KV
ADA 26
44
MEASUREMENT
TRANSFORMERS FACTORY
Burden Up to 30VA
45
MEASUREMENT
TRANSFORMERS FACTORY
Classes Of Potential
Description
Transformer
Potential Transformer
GDA 12
12 KV
Potential Transformer
GDB 24
24 KV
46
MEASUREMENT
TRANSFORMERS FACTORY
Potential transformers Description
Operating Voltage / / V
Operating Voltage / / V
50 VA
Burden
100VA
47
EGEMAC MAP
48
HIGH VOLTAGE FACTORY
• EGEMAC High Voltage Factory
assembles Circuit Breaker
220KV & 66KV according to the
Technical Cooperation with ALSTOM.
• EGEMAC Performs all routine tests
in the High Voltage Factory for all
clients before shipping the products
to the site.
• EGEMAC is responsible for the
assembly of Circuit breaker,
Disconnector switches and
Measurement Transformers before
Shipping them to the Substation site.
49
MEASUREMENT
TRANSFORMERS FACTORY
Circuit Breaker Description
Breaking Capacity Up to 50 KA
50
MEASUREMENT
TRANSFORMERS FACTORY
Breaking Capacity Up to 40 KA
51
EGEMAC GROUP
52
• XD performs High Voltage turnkey projects.
• XD EGEMAC is responsible for manufacturing & assembly of the GIS Switchgear up to 500KV.
• XD EGEMAC participates in EETC since 2012.
53
Reference List:
1. Abu-Ghaleb S/S (220KV)
2. Banha S/S (220KV)
3. Benban 1,2,3 & 4 S/S (220KV)
4. Demiatte S/S (66KV)
54
EGEMAC GROUP
IS COMING
55
REFERENCE LIST
HIGH VOLTAGE SUBSTATIONS REFERENCE LIST
56
REFERENCE LIST
MEDIUM VOLTAGE SUBSTATIONS REFERENCE LIST
57
REFERENCE LIST
MEDIUM VOLTAGE SUBSTATIONS REFERENCE LIST
58
REFERENCE LIST
EGEMAC at Exhibitions
59
THANK YOU
ANY QUESTIONS?