Measurement of Earth Resistance

The document discusses the measurement of earth resistance. An effective earth electrode is necessary for safety and stabilization of electrical systems. It must have low resistance to carry large fault currents without damage. Since current is difficult to measure, earth resistance is used as a reliable indicator of effectiveness. Factors like electrode material, depth, and soil composition affect resistance, which can vary seasonally. Periodic testing ensures the earth system remains effective over time. Common methods to measure earth resistance include the fall of potential method using auxiliary electrodes and instruments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
133 views12 pages

Measurement of Earth Resistance

The document discusses the measurement of earth resistance. An effective earth electrode is necessary for safety and stabilization of electrical systems. It must have low resistance to carry large fault currents without damage. Since current is difficult to measure, earth resistance is used as a reliable indicator of effectiveness. Factors like electrode material, depth, and soil composition affect resistance, which can vary seasonally. Periodic testing ensures the earth system remains effective over time. Common methods to measure earth resistance include the fall of potential method using auxiliary electrodes and instruments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 12

MEASUREMENT OF EARTH RESISTANCE

Necessity of Earth Electrode:

1. safety: All the parts of electrical equipment, like casings of machines, switches and
circuit breakers, lead sheathing and armoring of cables, tanks of transformers, etc.
which have to be at earth potential, must be connected to an earth electrode.
The purpose of this is to protect the various parts of the installation, as well as the
persons working, against damage in case the insulation of a system fails at any point .

2. The earth electrode ensures that in the event of overvoltage on the system due to
lightning discharges or other system faults, those parts of equipment which are
normally' dead' as far as voltages are concerned, do not attain dangerously high
potentials .

3. In a three phase circuit the neutral of the system is earthed in order to stabilize the
potential of the circuit with respect to earth.
Necessity of Measurement of Resistance of Earth Electrode

An earth electrode will only be effective so long it has a low resistance to the earth and
can carry large currents without deteriorating. Since the amount of current which an
earth electrode will carry is difficult to measure, the resistance value of the earth
electrode is taken as sufficiently reliable indication of its effectiveness.

Thus the resistance of earth electrode should be low to give good protection and it must
be measured.

Factors affecting Earth Resistance:


1. Shape and material of earth electrode or electrodes used.
2. Depth in the soil at which the electrodes are buried
3. Specific resistance· of soil surrounding and in the neighborhood of electrodes. The
amount of moisture present in the soil effects is specific resistance and hence the
resistance of earth electrode is not a constant factor but suffers seasonal variations.
This calls for periodic testing to ensure that the earth system remains reasonably
effective.
Methods of Measuring Earth Resistance
Fall of Potential method
‘A’ and ‘B’ are Auxiliary electrodes. Current flows between E and B. Voltage is
measured between ‘A’ and ‘E’.
The position of ‘E’ and ‘B’ are fixed and ‘A’ is moved from closer to ‘E’ to closer to ‘B’.
The voltages are plotted for various positions of ‘A’. The voltage changes rapidly at
closer positions of ‘A’ to ‘E’ and ‘B’
The correct value of resistance of cari h, R1·:; is whc11 :the auxiliary eleclrode A is at
such
a distance tLat the resistance lies on the flat part of curve
PMMC & Electro dynamic instrument & Moving Iron