Practical for NDT

(RI)

By Untung Budi
Testing of Weld

A DT Destructive Test
B NDT ( Non Destructive Test)
– Visual
– PT ( penetrant Test)
– MPI (Magnetic Particle Test)
– UT( Ultrasonic Test) advances call Phased Array UT
– RT(Radiographic Test)
RT

– X Tray
– Gama Ray
– Iridium 192(75 day)
– Caesium 137(30 year)
– Radium 226(1600year)
– Thuium 170+(130 day)
– Chobal Co 60(5.3Year)
X - Rays Gamma Rays

Electrically generated Generated by the


decay of unstable
atoms
Source

Radiation beam Image quality indicator

10fe16
Radiographic film Test specimen
Density - relates to the
degree of darkness

Contrast - relates to the degree of difference

Definition - relates to the degree of sharpness

Sensitivity - relates to the overall quality of the


radiograph
7FE12

Step / Hole type IQI Wire type IQI


 Single Wall Single Image (SWSI)
- film inside, source outside
 Single Wall Single Image (SWSI) panoramic
- film outside, source inside (internal exposure)
 Double Wall Single Image (DWSI)
- film outside, source outside (external exposure)
 Double Wall Double Image (DWDI)
- film outside, source outside (elliptical exposure)
–  As per table gamma exposure chart
T
T :Time exposure
EF :Exposure Factor
D(sfd) :Distance Source to film
I : Curie
Example:
If you had a 50 curie source of IR-192 and were going to
radiograph 2 inch steel with source to film distance 20
inch ,what will be the exposure time that would give a
density 2 ?
 
T

–  
T
T minutes
Advantages
 - Permanent record
 - Little surface preparation
 - Defect identification
 - No material type limitation
 - Not so reliant upon operator skill
 -Thin materials
*Expensive consumables
Disadvantages
*Bulky equipment
*Harmful radiation
*Defect require significant depth in relation to the radiation beam
*Slow results
*Very little indication of depths
*Access to both sides required
Preparation For Interpretation of Film
radiographic

– Procedure To be used is approved


– Equipment tool to be verification / calibrated
– Densitometer
– Step-wedge
– Viewer ( 30~300 cd/M2)
– Clear Ruler ( plastic )
– Pencil mark
Reference BS 2600P1
– Type film as per Procedure
– Defect Film if any
– Fogging
– Process Defect( water mark, chemical Stains)
– Scratch , finger mark crimps
– False indications
– IQI (Image Quality Indicator)
– Density of radiograph
– Identification
Standard and Code to be Used

– ASME V Nondestructive Examination article 2


– ASME IX Welding, Brazing and Fusing Qualification
– AWSD1.1 Structural Welding Code Steel
– ASME 31.1 Power Piping 136 4.5
– ASME 31.3 Process Piping Table 341.3.2
– API 1104 Welding of Pipeline and Related facilities para
9.3