0% found this document useful (0 votes)
66 views14 pages

Moradabad Institute of Technology: Electrical Department

The document discusses harmonic reduction using transformer connection. Harmonics are voltages or currents at multiples of the fundamental frequency that distort voltage waveforms. Connecting two inverters with phase-shifted outputs to the primary windings of series-connected transformers can eliminate the 3rd harmonic from the combined output voltage waveform. This technique reduces harmonics without requiring additional hardware beyond two inverters and transformers.

Uploaded by

Abhishek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views14 pages

Moradabad Institute of Technology: Electrical Department

The document discusses harmonic reduction using transformer connection. Harmonics are voltages or currents at multiples of the fundamental frequency that distort voltage waveforms. Connecting two inverters with phase-shifted outputs to the primary windings of series-connected transformers can eliminate the 3rd harmonic from the combined output voltage waveform. This technique reduces harmonics without requiring additional hardware beyond two inverters and transformers.

Uploaded by

Abhishek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 14

MORADABAD INSTITUTE OF

TECHNOLOGY
ELECTRICAL DEPARTMENT
PRESENTATION ON HARMONIC REDUCTION USING
TRANSFORMER CONNECTION
.

Presentation by:-
Seminar Seminar Guide:- Manish
Coordinator:- Mr.Maroof Ali Roll No.1608220017
Mr. Maroof Ali
EE
CONTENT

INTRODUCTION


DEFINATION


HARMONIC REDUCTION USING TRANSFORMER CONNECTION


OUTPUT WAVEFORM


HARMONIC IN INVERTER


ADVANTAGE


DISADVANTAGE


REFREANCE HARMONIC
Introduction
Harmonics:

 We define harmonics as
voltages or currents at
frequencies that are a
multiple of the
fundamental frequency.
 The biggest problem
with harmonics is
voltage waveform
distortion.
Harmonics

f(x) = sin(x) sin(5x)


f(x) = 5
The resulting wave shows a strong departure from the smooth
waves comprising it:

= f(x) = sin(x) + sin(5x)


5
Harmonics in inverter
 There are several industrial applications which may
allow a harmonic of 5%of its fundamental component of
input voltage when inverters are used.
 The inverter output voltage may have harmonic content
much higher then 5% of its fundamental component.
 Several methods available for reduction of harmonics in
output voltage of inverter.
Harmonic reduction using Transformer
connection

 Conditions for use this method


 Two or more inverters are required
 Inverters outputs must be phase shifted.

 With the help of this method we can reduce 3rd harmonic

 So, multiple of 3rd harmonics 9,15,…… also removed.


Harmonic reduction using
transformer connection
Conti….
 The second inverter output is П/3 radians phase shifted then
inverter one output.
 The resultant output voltage is obtained by adding vertical
ordinates of V01 And V02.
 According to shown in figur7e two inverters are connected at
two primary windings of two transformers and both
transformers are series connected.
Conti…..
 The Fourier analysis of V01 and V02 gives

 V01=A1sin(x)+A3sin(3x)+A5sin(x)+A7sin(x)……
V02=A1sin(X- П/3 )+A3sin3(X- П/3 )
+A5sin5(X- П/3)+A7sin5(X- П/3)…….
 The resultant voltage V=V01+V02,
V=A1sin(X- П/6 )+A5sin5(X- П/6)+A7sin5(X- П/6)
…….
Conti…

V=A1sin(X- П/6 )+A5sin5(X- П/6)+A7sin5(X- П/6)


…….
We can see the resultant voltage does not have 3

multiplication term.So,3rd harmonics is eliminated and


also the multiple of 3 are eliminated like 9,15,..
Harmonic reduced output obtain only if the output of
inverter 2 is phase shifted then output of inverter 1.
Output waveform
ADVANTAGE

 A harmonic analyser is a device which is used to


measure frequencies, amplitudes, different phases.
 It mainly consists of multipliers, an input device, and
integrators.
 Using a harmonic analyser, industries can significantly
improve their energy efficiency by adopting all possible
measures.
Disadvantages

1. Two or more transformers are required.


2. Transformers of similar rating required.
Thank you