Blok Diagram Fungsional

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 28

BLOK DIAGRAM

FUNGSIONAL
BLOCK DIAGRAM

Input Process Output

• COMPONENT OR PROCESS TO BE CONTROLLED CAN BE REPRESENTED BY


A BLOCK DIAGRAM.
• THE INPUT-OUTPUT RELATIONSHIP REPRESENTS THE CAUSE AND EFFECT
OF THE PROCESS.
CONTROL SYSTEM CLASSIFICATION
• AN OPEN-LOOP CONTROL SYSTEM UTILIZES AN ACTUATING
DEVICE TO CONTROL THE PROCESS DIRECTLY WITHOUT
USING FEEDBACK.
Desired Output Actuating
Process Output
Response Device

• A CLOSED-LOOP FEEDBACK CONTROL SYSTEM USES A


MEASUREMENT OF THE OUTPUT AND FEEDBACK OF THE
Desired
OUTPUT
Output
SIGNAL TO COMPARE
Comparison
IT WITH THE
Controller
DESIRED OUTPUT
Process Output
OR REFERENCE.
Response

Measurement

Single Input Single Output (SISO) System


CONTROL SYSTEM CLASSIFICATION
Missile Launcher System

Open-Loop Control System


CONTROL SYSTEM CLASSIFICATION
Missile Launcher System

Closed-Loop Feedback Control System


CONTROL SYSTEM CLASSIFICATION
Desired
Output Controller Process Output
Response Variables

Measurement

Multi Input Multi Output (MIMO) System


PURPOSE OF CONTROL SYSTEMS

i.POWER AMPLIFICATION (GAIN)


• POSITIONING OF A LARGE RADAR ANTENNA BY LOW-POWER
ROTATION OF A KNOB

ii.REMOTE CONTROL
HISTORICAL DEVELOPMENTS

i.ANCIENT GREECE (1 TO 300 BC)


• WATER FLOAT REGULATION, WATER CLOCK, AUTOMATIC OIL LAMP

ii.CORNELLIS DREBBEL (17TH CENTURY)


• TEMPERATURE CONTROL

iii.JAMES WATT (18TH CENTURY)


WATT’S FLYBALL GOVERNOR
TEMPERATURE CONTROL

 FIGURE SHOWS A SCHEMATIC DIAGRAM OF TEMPERATURE CONTROL OF AN ELECTRIC


FURNACE. THE TEMPERATURE IN THE ELECTRIC FURNACE IS MEASURED BY A
THERMOMETER, WHICH IS ANALOG DEVICE. THE ANALOG TEMPERATURE IS CONVERTED TO
A DIGITAL TEMPERATURE BY AN A/D CONVERTER. THE DIGITAL TEMPERATURE IS FED TO A
CONTROLLER THROUGH AN INTERFACE. THIS DIGITAL TEMPERATURE IS COMPARED WITH
THE PROGRAMMED INPUT TEMPERATURE, AND IF THERE IS ANY ERROR , THE CONTROLLER
SENDS OUT A SIGNAL TO THE HEATER, THROUGH AN INTERFACE, AMPLIFIER AND RELAY TO
BRING THE FURNACE TEMPERATURE TO A DESIRED VALUE.
TRANSPORTATION
CAR AND DRIVER

• OBJECTIVE: TO CONTROL DIRECTION AND SPEED OF CAR


• OUTPUTS: ACTUAL DIRECTION AND SPEED OF CAR
• CONTROL INPUTS: ROAD MARKINGS AND SPEED SIGNS
• DISTURBANCES: ROAD SURFACE AND GRADE, WIND, OBSTACLES
• POSSIBLE SUBSYSTEMS: THE CAR ALONE, POWER STEERING SYSTEM,
BREAKING SYSTEM
TRANSPORTATION
• FUNCTIONAL BLOCK DIAGRAM:
Desired Actual
course course
of travel + Error Steering of travel
Driver Automobile
- Mechanism

Measurement, visual and tactile

• TIME RESPONSE:
TRANSPORTATION
• CONSIDER USING A RADAR TO MEASURE DISTANCE AND
VELOCITY TO AUTONOMOUSLY MAINTAIN DISTANCE
BETWEEN VEHICLES.

• AUTOMOTIVE: ENGINE REGULATION, ACTIVE SUSPENSION,


ANTI-LOCK BREAKING SYSTEM (ABS)
PROCESS INDUSTRY
 CONTROL USED TO REGULATE LEVEL, PRESSURE AND PRESSURE OF REFINERY
VESSEL.

Coordinated
control system
for a boiler-
generator.

 FOR STEEL ROLLING MILLS, THE POSITION OF ROLLS IS CONTROLLED BY THE


THICKNESS OF THE STEEL COMING OFF THE FINISHING LINE.
MANUFACTURING INDUSTRY
• CONSIDER A THREE-AXIS CONTROL SYSTEM FOR INSPECTING
INDIVIDUAL SEMICONDUCTING WAFERS WITH A HIGHLY
SENSITIVE CAMERA
HOMES
i.CD PLAYERS
• THE POSITION OF THE LASER SPOT IN RELATION TO THE
MICROSCOPIC PITS IN A CD IS CONTROLLED.

ii.AIR-CONDITIONING SYSTEM
• USES THERMOSTAT AND CONTROLS ROOM
CONTROL SYSTEM COMPONENTS

i.SYSTEM, PLANT OR PROCESS


• TO BE CONTROLLED

ii.ACTUATORS
• CONVERTS THE CONTROL SIGNAL TO A POWER SIGNAL

iii.SENSORS
GENERAL CONTROL SYSTEM
Disturbance

Controlled Manipulated
Set-point Error Signal Variable
or
Reference Actual
input + + Output
+
+ Controller Actuator + Process
-

Sensor
Feedback Signal
CONTROL SYSTEM DESIGN PROCESS
1. Establish control goals

2. Identify the variables to control

3. Write the specifications for the variables

4. Establish the system configuration and identify the actuator

If the performance does not 5. Obtain a model of the process, the actuator and the sensor
meet specifications, then
iterate the configuration and
actuator
6. Describe a controller and select key parameters to be adjusted

7. Optimize the parameters and analyze the performance

If the performance meet the specifications, then finalize design


TURNTABLE SPEED CONTROL
• APPLICATION: CD PLAYER, COMPUTER DISK DRIVE
• REQUIREMENT: CONSTANT SPEED OF ROTATION
• OPEN LOOP CONTROL SYSTEM:

• BLOCK DIAGRAM REPRESENTATION:


TURNTABLE SPEED CONTROL
• CLOSED-LOOP CONTROL SYSTEM:

• BLOCK DIAGRAM REPRESENTATION:


PROS & CONS SISTEM KENDALI TERBUKA

• PADA UMUMNYA LEBIH SEDERHANA DIBANDING CLOSED


LOOP
• TIDAK MEMERLUKAN SENSOR UNTUK MENGUKUR
OUTPUT
KEUNTUNGAN CLOSED LOOP

• SISTEM YANG DIBUAT DENGAN BAIK AKAN DAPAT MERESPON KEJADIAN-


KEJADIAN YANG TIDAK TERPREDIKSI SEBELUMNYA
• MENGHILANGKAN KEBUTUHAN TERHADAP ADANYA MANUSIA UNTUK
MENGATUR VARIABEL PROSES
• MENURUNKAN BEBAN KERJA MANUSIA
• MEMBERIKAN PERFORMA YANG LEBIH DIBANDINGKAN OPEN LOOP DALAM
PROBLEM PADA CLOSED LOOP

• LEBIH KOMPLEKS DIBANDING OPEN LOOP


• MUNGKIN TERJADI STEADY STATE ERROR
• SANGAT TERGANTUNG KEPADA AKURASI PENGUKURAN
DISK DRIVE READ SYSTEM

GOAL OF THE SYSTEM: POSITION THE READER HEAD IN


ORDER TO READ DATA STORED ON A TRACK.
VARIABLES TO CONTROL: POSITION OF THE READER HEAD
DISK DRIVE READ SYSTEM
• SPECIFICATION:
i. SPEED OF DISK: 1800 RPM TO 7200 RPM
ii. DISTANCE HEAD-DISK: LESS THAN 100NM
iii. POSITION ACCURACY: 1 ΜM
iv. MOVE THE HEAD FROM TRACK ‘A’ TO TRACK ‘B’ WITHIN
50MS
• SYSTEM CONFIGURATION:
ASSIGNMENT 1
• DESKRIPSIKAN PRINSIP OPERASI (KINERJA)
WATT’S FLYBALL GOVERNOR. TERMASUK
DIDALAMNYA ADALAH BLOCK DIAGRAM YANG
MENGINDIKASIKAN FUNGSI MASING-MASING
KOMPONEN. (CARI DI GOOGLE)
• TUGAS ANDA SEHARUSNYA TIDAK LEBIH DARI 2
HALAMAN YANG DIKERJAKAN SECARA
MANDIRI DENGAN DIKETIK KOMPUTER DAN
DICETAK PADA A4
• TUGAS SEHARUSNYA DIKUMPULKAN PADA
FURTHER READING…

• CHAPTER 1
i. NISE N.S. (2004). CONTROL SYSTEM ENGINEERING (4TH ED), JOHN
WILEY & SONS.

You might also like