FieldMate Update - IPBM2012 -

Solution Gr. PMK Dept.


Field Instruments Business Headquarters
Yokogawa Electric Corporation
Nov 8th, 2012

<Document Number>
Copyright © Yokogawa Electric Corporation -1-
<date/time>
Internal Use Only
Contents

FieldMate History
New Features of FieldMate R2.05
– Enhanced ISA100.11a support
– Device Replacement tool
– Multi-Language
– AXF Verification Tool
– New DTM Line Up in FieldMate R2.05/DeviceFiles
R3.04
Information
– Related Information Site for FieldMate and ADMAG

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -2-
<Nov.2012>
<Internal Use Only>
FieldMate History

<Document Number>
Copyright © Yokogawa Electric Corporation -3-
<date/time>
FieldMate History

2008 2009 2010 2011 2012 2013

R2.01.00 Jan,2009 R2.02 Jun, 2010 R2.03 Feb, 2011


R2.05 Aug, 2012
- Windows Vista - HART 7 - Windows 7 - Multi-Language (6 languages)
- HART Protocol - ISA100R1 - Chinese Language - Device Replacement Tool
Provisioning -ISA100R1 IR-modem
- AXF Verification Tool

R2.01.01 Apr,2009 R2.04 Sep, 2011


- HART Enhanced - ISA100 R1.5 GW P&P
Device Tag - ISA100 R2 PROFIBUS Improved.
- DTM Works Improved.

Multi-Language Device Replacement Tool AXF Verification Tool

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -4-
<Nov.2012>
<Internal Use Only>
New Features of FieldMate R2.05

<Document Number>
Copyright © Yokogawa Electric Corporation -5-
<date/time>
New Features of FieldMate R2.05

Device Replacement tool


Multi Language support
Enhanced ISA100.11a support
AXF Verification Tool
New DTM Line Up

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -6-
<Nov.2012>
<Internal Use Only>
Outline of Device Replacement Tool

Device Parameter Conversion Function


 Device parameters will be converted to your selected Yokogawa
devices and make ease for replacement project.
Conversion From Other Vendors Yokogawa Devices From HART 5 to 7
Emerson Yokogawa HART 5 HART 5/7
1151 EJA-A/EJA (HART5) EJA-A/EJA EJA-E/EJX
2051 EJA-E (HART5/7) EJA-E EJA-E/EJX
3051C/S EJX (HART5/7) EJX EJA-E/EJX

Basic or Advance

[ Yokogawa ] [ Yokogawa ]

Parameter
Conversion
[ Other ] [ Yokogawa ]

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -7-
<Nov.2012>
<Internal Use Only> 7
Operation of Device Replacement Tool
1. Start the “Device 2. Upload 3. Download
Replacement Tool” parameters from parameters to new
program. original devices. devices.
[All Program]→[Yokogawa
FieldMate]→[Tools]→[Device
Replacement Tool]
Save data. Load data.

• Parameters to be converted
Tag, Long Tag, LRV, URV, Unit, Pres Damp,
Descriptor, Message, Xfer fnctn
Note:
•“Field Mate” and “Device Replacement Tool” doesn’t work simultaneously.
<IPBM2012_F02>
•Uploading device and Copyright
downloading
<Nov.2012>
© Yokogawa device cannot connect
Electric Corporation -8- at same time. Please achieve uploading and
downloading one by one. <Internal Use Only>
Movie of device replacement tool

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -9-
<Nov.2012>
<Internal Use Only>
Multi Language support
German, French, Russian, English, Japanese ,Chinese

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 10 -
<Nov.2012>
<Internal Use Only>
Multi-Language -Product Document for FieldMate R2.05-
Attached Document in the Shipping Product
– Getting Started
• English, Chinese, German, French, Russia, Japanese
– Operational Precaution
• English, Japanese
Document of Downloading from WEB
– FieldMate IM
• English, Chinese*, German, French*, Japanese
– Operational Precaution
• Chinese*, German, French*
– PRM Sync
• English, German, French*, Japanese
– AXF Verification Tool
• English Only
*: In Progress

Document Download Site for FieldMate


http://www.yokogawa.com/fld/doc/manual/fld-fieldmate-manual-01en.htm

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 11 -
<Nov.2012>
<Internal Use Only>
Enhanced ISA100.11a support
Up to 200 ISA100.11a field wireless devices can be connected to FieldMate, and
Search and Registration functions are improved.
• Device Search Function
−Various search items and Multi Condition Search Functions are enhanced.
• Registration of Device Maintenance Information files at a time.
Movie on FAN Site: http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx

• Search Functions • Registration of Multiple Device


Maintenance Information
・Search
items
  ・Device Tag
  ・ Status
・Device ID
・Model
  ・ etc

・Multi condition
search
Select multiple conditions
(items) to search.
Multiple devices can be selected
to register at a time.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 12 -
<Nov.2012>
<Internal Use Only>
AXF Verification Tool

<Document Number>
Copyright © Yokogawa Electric Corporation - 13 -
<date/time>
Outline of AXF Verification Tool
“AXF Verification Tool” allows you to verify and confirm health and integrity of AXF series
without removing flowmeters from line. By performing this verification tool, ±2% of original
factory calibration is confirmed (±5% when standard verification only). If all verification items
are achieved and passed, “±2% of original factory calibration” is confirmed even when
it’s passed five or ten years.
Verification results can be printed out and save as data base of FieldMate. It is designed to help
reduce your operating costs and optimized for reporting, periodic maintenance, adhesion check
and so on.
Print-out sample

Image
FSA111 FieldMate Advance Model
-S11 (Always “S11”)
/VF AXF Verification Tool

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 14 -
<Nov.2012>
<Internal Use Only>
Demand of AXF Verification Tool
In accordance with Rules and Regulation of EPA(Environmental
Protection Agency) in US, owner of a facility is subject to requirements
to submit annual GHG(Greenhouse Gas) reports to the Administrator.
Flowmeters has to be performed all calibrations at measurement points
to improve wasteful operation. The calibration error at each
measurement points shall not exceed 5% of reference value.

CO2, CH4, N2O and fluorinated GHG have to


be monitored to meet emission standards.

For optimized plant


operation,
flowmeters have to
be calibrated!

温室効果ガス
Part of paragraph of “PART 98—MANDATORY
<IPBM2012_F02>
GREENHOUSE GAS REPORTING” in the “Federal
Copyright © Yokogawa Electric Corporation - 15 - Register / Vol. 74, No. 209 / Friday, October 30,
<Nov.2012>
<Internal Use Only> 2009 / Rules and Regulations”
Specifications of AXF Verification Tool
Applicable Models : AXF 2.5 ~ 2600mm
– AXFA11 Magnetic Flowmeter Remote Converter and its remote flow tube
– AXFA14 Magnetic Flowmeter Remote Converter and its remote flow tube
– AXF Integral Type (Insulation Resistance test is not applicable for
integral type.)
Protocol
– HART protocol only
Functions
– Verifications
• Standard Verification: ±5% of original factory calibration
– Items: Circuit, Device Status, Physical Appearance
• Enhanced Verification: ±2% of original factory calibration
– Items: Current Output, Pulse Output, Converter, Insulation Resistance
» Condition for 2%: Nominal Size <=400 mm, W/O /ELC DC Noise Cut Circuit option
– File Save
• Verification result can be saved as device maintenance information of
FieldMate, and can be overwritten repeatedly to the same file.
– Print-Out
• Verification result can be printed out at any time by loading from data base.
Language
– English (No multi-language support)
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 16 -
<Nov.2012>
<Internal Use Only>
Standard / Enhanced Verification of AXF Verification Tool
Item Description Result when passed Equipment
Magnetic Circuit Electrode Level
Excitation Circuit Fluid Adhesion
Flow
Calculation Excited Current
Circuit Dual Frequency
Circuit
Magnetic Circuit Zero Adjustment
No Excitation Circuit Electrode Level FieldMate
Verified to be
Flow Calculation Fluid Adhesion only
Standard functioning within (FSA111-S11/VF
Verification Circuit Excited Current +-5.0% of original : FieldMate R2.05
Alarm Check Present alarms factory calibration. with /VF option,
Device Status
Alarm History Occurred alarms HART modem)
No Deformation,
Damage, Corrosion,
Physical Flow tube Cracking, Abrasion and
Appearance Leaks.
No Corrosion, Damage,
Converter moisture in the housing
Current Output 4/12/20mA
FieldMate,
Pulse Output 2 or 100 pps Verfied to be
CA150,
Enhanced Converter 0/25/50/75/100% functioning within
AM012,
Verification Coil >=1M ohm (500VDC) +-2.0% of original
Insulation Insulation
>=100M ohm factory calibration.
Resistance Electrode Checker
(500VDC)

* “2%” can be confirmed under following conditions.


 Without DC Noise Cut Circuit (/ELC option)
 Nominal size is equal or less than 400mm.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 17 -
<Nov.2012> “No Flow” item of Standard Verification is passed.

<Internal Use Only>
Operation of Verification Tool

1. Start from Verification Tool in


Segment Viewer display.
2. Fill-in the name of Verified Person
and other general information.

3. Perform Standard and


Enhanced Verification.

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 18 -
<Nov.2012>
<Internal Use Only>
Standard Verification Items

 Display Example of “Standard Verification” • Circuit


Magnetic, Excitation and
Calculation Circuits are
verified by the internal self-
diagnostics like zero adjust,
electrode level and resistance,
excitation current and
calculation of dual frequency
excitation.
5% can be confirmed by only
“Flow” or “No flow”
Device Status
• calibration.
Alarm Check: Most of errors of
self-test are reflected to the
result, including span setting
error.
Alarm History: It will be failed
when serious errors occurred.
• Physical Appearance
Enter result of Pass, Fail or
N/A by manual.
Criteria: No Deformation,
damage, corrosion, cracking,
abrasion leaks.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 19 -
<Nov.2012>
<Internal Use Only>
Enhanced Verification Items

 Display Example of “Enhanced Verification”


• Current Output
4/12/20 mA current output
checked by CA150 or
multi-meter.
• Pulse Output
2 or 100 pps (pulse per sec)
checked by CA150 or
frequency counter.

• Converter
Display values of converter at
0, 25, 50, 75 and 100%
checked by AM012.

• Insulation Resistance
of Coil and electrode.
(Not mandatory)
Criteria:
Coil: >=1M ohm
Signal: >=100M ohm

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 20 -
<Nov.2012>
<Internal Use Only>
Sample of Verification Report

 Display Example of “Result” Result in full view

Tag name, serial number


and verified person can
be revised afterwards.
Other parameters and
results are protected to
rewrite.

Verification result can be printed out any time by loading from data
base of FiledMate Device Maintenance Information.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 21 -
<Nov.2012>
<Internal Use Only>
Movie of AXF Verification Tool

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 22 -
<Nov.2012>
<Internal Use Only>
New DTM Line Up in FieldMate R2.05/DF R3.04
DTM Lineup included in R3.03.00 Device Files and Updates

Device Files R3.03.00 R3.04.00


FieldMate R2.04.00 R2.05.00
Schedule 2011 End of September 2012 Middle of August
HART EJX910 DevRev2 DY DevRev4
RCCT F3 DevRev4 AXR DevRev2
EJX910/930   DevRev10 (HART DY DevRev10 ( HART7 )
7) AXR   DevRev10 ( HART7)
EJA-E DevRev1
EJA-E DevRev10(HART7)
FF EJX910 DevRev2 YTA DevRev4
EJX   DevRev4  ( ITK5.2 ) AXF DevRev2 ( ITK5.2 )
EJX DevRev5
EJA-E DevRev1
ISA100 EJX, YTA (R1.5) EJX, YTA DevRev2
YTMX (Temp MUX) New gateway   Comm DTM
HART Adapter

<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 23 -
<Nov.2012>
<Internal Use Only>
Information

<Document Number>
Copyright © Yokogawa Electric Corporation - 24 -
<date/time>
Related Information Site for FieldMate and ADMAG

FieldMate R2.05 New Features:


http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx

AXF Verification Tool Catalog:


http://www.yokogawa.com/fld/pdf/AXF/BU01E20R01-01EN.pdf

AXF Verification Tool User’s Manual:


http://www.yokogawa.com/fld/pdf/AXF/IM01R01A11-01EN.pdf

Introduction Movie:
–AXF Verification Tool AXF Verification Tool Flier
BU01E20R01-01EN
http://fan.gbl.ykgw.net/Pages/Field/fld-magmeter.aspx
–Device Replacement Tool
http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx
–Enhanced functions for ISA100.11a
http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx

ADMAG Magnetic Flowmeters Promotion Site:


http://www.admagaxf.com/
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 25 -
<Nov.2012>
<Internal Use Only>