FieldMate Update r4
FieldMate Update r4
<Document Number>
Copyright © Yokogawa Electric Corporation -1-
<date/time>
Internal Use Only
Contents
FieldMate History
New Features of FieldMate R2.05
– Enhanced ISA100.11a support
– Device Replacement tool
– Multi-Language
– AXF Verification Tool
– New DTM Line Up in FieldMate R2.05/DeviceFiles
R3.04
Information
– Related Information Site for FieldMate and ADMAG
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -2-
<Nov.2012>
<Internal Use Only>
FieldMate History
<Document Number>
Copyright © Yokogawa Electric Corporation -3-
<date/time>
FieldMate History
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -4-
<Nov.2012>
<Internal Use Only>
New Features of FieldMate R2.05
<Document Number>
Copyright © Yokogawa Electric Corporation -5-
<date/time>
New Features of FieldMate R2.05
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -6-
<Nov.2012>
<Internal Use Only>
Outline of Device Replacement Tool
Basic or Advance
[ Yokogawa ] [ Yokogawa ]
Parameter
Conversion
[ Other ] [ Yokogawa ]
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -7-
<Nov.2012>
<Internal Use Only> 7
Operation of Device Replacement Tool
1. Start the “Device 2. Upload 3. Download
Replacement Tool” parameters from parameters to new
program. original devices. devices.
[All Program]→[Yokogawa
FieldMate]→[Tools]→[Device
Replacement Tool]
Save data. Load data.
• Parameters to be converted
Tag, Long Tag, LRV, URV, Unit, Pres Damp,
Descriptor, Message, Xfer fnctn
Note:
•“Field Mate” and “Device Replacement Tool” doesn’t work simultaneously.
<IPBM2012_F02>
•Uploading device and Copyright
downloading
<Nov.2012>
© Yokogawa device cannot connect
Electric Corporation -8- at same time. Please achieve uploading and
downloading one by one. <Internal Use Only>
Movie of device replacement tool
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation -9-
<Nov.2012>
<Internal Use Only>
Multi Language support
German, French, Russian, English, Japanese ,Chinese
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 10 -
<Nov.2012>
<Internal Use Only>
Multi-Language -Product Document for FieldMate R2.05-
Attached Document in the Shipping Product
– Getting Started
• English, Chinese, German, French, Russia, Japanese
– Operational Precaution
• English, Japanese
Document of Downloading from WEB
– FieldMate IM
• English, Chinese*, German, French*, Japanese
– Operational Precaution
• Chinese*, German, French*
– PRM Sync
• English, German, French*, Japanese
– AXF Verification Tool
• English Only
*: In Progress
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 11 -
<Nov.2012>
<Internal Use Only>
Enhanced ISA100.11a support
Up to 200 ISA100.11a field wireless devices can be connected to FieldMate, and
Search and Registration functions are improved.
• Device Search Function
−Various search items and Multi Condition Search Functions are enhanced.
• Registration of Device Maintenance Information files at a time.
Movie on FAN Site: http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx
・Multi condition
search
Select multiple conditions
(items) to search.
Multiple devices can be selected
to register at a time.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 12 -
<Nov.2012>
<Internal Use Only>
AXF Verification Tool
<Document Number>
Copyright © Yokogawa Electric Corporation - 13 -
<date/time>
Outline of AXF Verification Tool
“AXF Verification Tool” allows you to verify and confirm health and integrity of AXF series
without removing flowmeters from line. By performing this verification tool, ±2% of original
factory calibration is confirmed (±5% when standard verification only). If all verification items
are achieved and passed, “±2% of original factory calibration” is confirmed even when
it’s passed five or ten years.
Verification results can be printed out and save as data base of FieldMate. It is designed to help
reduce your operating costs and optimized for reporting, periodic maintenance, adhesion check
and so on.
Print-out sample
Image
FSA111 FieldMate Advance Model
-S11 (Always “S11”)
/VF AXF Verification Tool
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 14 -
<Nov.2012>
<Internal Use Only>
Demand of AXF Verification Tool
In accordance with Rules and Regulation of EPA(Environmental
Protection Agency) in US, owner of a facility is subject to requirements
to submit annual GHG(Greenhouse Gas) reports to the Administrator.
Flowmeters has to be performed all calibrations at measurement points
to improve wasteful operation. The calibration error at each
measurement points shall not exceed 5% of reference value.
温室効果ガス
Part of paragraph of “PART 98—MANDATORY
<IPBM2012_F02>
GREENHOUSE GAS REPORTING” in the “Federal
Copyright © Yokogawa Electric Corporation - 15 - Register / Vol. 74, No. 209 / Friday, October 30,
<Nov.2012>
<Internal Use Only> 2009 / Rules and Regulations”
Specifications of AXF Verification Tool
Applicable Models : AXF 2.5 ~ 2600mm
– AXFA11 Magnetic Flowmeter Remote Converter and its remote flow tube
– AXFA14 Magnetic Flowmeter Remote Converter and its remote flow tube
– AXF Integral Type (Insulation Resistance test is not applicable for
integral type.)
Protocol
– HART protocol only
Functions
– Verifications
• Standard Verification: ±5% of original factory calibration
– Items: Circuit, Device Status, Physical Appearance
• Enhanced Verification: ±2% of original factory calibration
– Items: Current Output, Pulse Output, Converter, Insulation Resistance
» Condition for 2%: Nominal Size <=400 mm, W/O /ELC DC Noise Cut Circuit option
– File Save
• Verification result can be saved as device maintenance information of
FieldMate, and can be overwritten repeatedly to the same file.
– Print-Out
• Verification result can be printed out at any time by loading from data base.
Language
– English (No multi-language support)
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 16 -
<Nov.2012>
<Internal Use Only>
Standard / Enhanced Verification of AXF Verification Tool
Item Description Result when passed Equipment
Magnetic Circuit Electrode Level
Excitation Circuit Fluid Adhesion
Flow
Calculation Excited Current
Circuit Dual Frequency
Circuit
Magnetic Circuit Zero Adjustment
No Excitation Circuit Electrode Level FieldMate
Verified to be
Flow Calculation Fluid Adhesion only
Standard functioning within (FSA111-S11/VF
Verification Circuit Excited Current +-5.0% of original : FieldMate R2.05
Alarm Check Present alarms factory calibration. with /VF option,
Device Status
Alarm History Occurred alarms HART modem)
No Deformation,
Damage, Corrosion,
Physical Flow tube Cracking, Abrasion and
Appearance Leaks.
No Corrosion, Damage,
Converter moisture in the housing
Current Output 4/12/20mA
FieldMate,
Pulse Output 2 or 100 pps Verfied to be
CA150,
Enhanced Converter 0/25/50/75/100% functioning within
AM012,
Verification Coil >=1M ohm (500VDC) +-2.0% of original
Insulation Insulation
>=100M ohm factory calibration.
Resistance Electrode Checker
(500VDC)
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 18 -
<Nov.2012>
<Internal Use Only>
Standard Verification Items
• Converter
Display values of converter at
0, 25, 50, 75 and 100%
checked by AM012.
• Insulation Resistance
of Coil and electrode.
(Not mandatory)
Criteria:
Coil: >=1M ohm
Signal: >=100M ohm
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 20 -
<Nov.2012>
<Internal Use Only>
Sample of Verification Report
Verification result can be printed out any time by loading from data
base of FiledMate Device Maintenance Information.
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 21 -
<Nov.2012>
<Internal Use Only>
Movie of AXF Verification Tool
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 22 -
<Nov.2012>
<Internal Use Only>
New DTM Line Up in FieldMate R2.05/DF R3.04
DTM Lineup included in R3.03.00 Device Files and Updates
<IPBM2012_F02>
Copyright © Yokogawa Electric Corporation - 23 -
<Nov.2012>
<Internal Use Only>
Information
<Document Number>
Copyright © Yokogawa Electric Corporation - 24 -
<date/time>
Related Information Site for FieldMate and ADMAG
Introduction Movie:
–AXF Verification Tool AXF Verification Tool Flier
BU01E20R01-01EN
http://fan.gbl.ykgw.net/Pages/Field/fld-magmeter.aspx
–Device Replacement Tool
http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx
–Enhanced functions for ISA100.11a
http://fan.gbl.ykgw.net/Pages/Field/fld-fieldmate.aspx
<Document Number>
Copyright © Yokogawa Electric Corporation - 26 -
<date/time>