Abb Relays

This document summarizes specifications for several types of relays used in railway signaling applications. It provides details on neutral line relays that operate at 60V DC, including models that are AC immunized and non-AC immunized. Specifications cover electrical parameters like coil resistance, pick up values, and contact ratings. It also lists various types of relays including neutral relays, interlocked relays, AC lamp proving relays, and key lock relays.

Uploaded by

pkhumesh1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
918 views18 pages

Abb Relays

This document summarizes specifications for several types of relays used in railway signaling applications. It provides details on neutral line relays that operate at 60V DC, including models that are AC immunized and non-AC immunized. Specifications cover electrical parameters like coil resistance, pick up values, and contact ratings. It also lists various types of relays including neutral relays, interlocked relays, AC lamp proving relays, and key lock relays.

Uploaded by

pkhumesh1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 18

ABB RELAYS

NEUTRAL

AC
IMMUNISED
INTERLOCKED
ECRs
CONTACT RATING :
 Steady Current Load : AS PER IRS S 46
3 Amp continuously and 5 Amp for 30 seconds
AS PER IHC
6 AMP continuously
 Breaking Capacity : AS PER IRS S 46 2 Amp
AS PER IHC 2 Amp at 220 V 50 Hz
 CONTACT WIPING : >/= 0.1 mm
 LIFE EXPECTENCY : 1 Million Switching Cycle or 10
Years which ever earlier.
o All Relays are Type Tested by RDSO as per
IRS : S46, IRS : S34 and IRS : S23 ( as applicable)
TYPE TMA NEUTRAL LINE RELAY 60 V DC ( Non AC Immunised )
1 SPECIFICATION
1.1 RELAY TYPE : TMA 1144/111 - GUM
TMA 1153/111 - GUM
TMA 1162/111 - GUM
TMA 1126/111 - GUM
TMA 1124/111 - GUM
TMA 1122/111 - GUM
1.2 RELAY RATINGS : 60 V DC + OR - 20%.
1.3 CONTACT CONFIGURATION : 4F/4B ; 5F/3B ; 6F/2B ; 2F/6B ; 2F/4B ; 2F2B &
any other contact combination of 8 contacts.
1.4 RELAY MOUNTING : With or without plug-in-base & with socket
2 ELECTRICAL PARAMETERS
2.1 COIL RESISTANCE : 1550 Ω + OR - 10% AT 20° C.C.
2.2 PICK UP VALUE : < OR = 48 V DC & > OR = 16 mA.
2.3 DROP OFF VALUE : > OR = 12 V DC & 5 mA.
2.4 HIGH VOLTAGE TEST : 2 KV for sixty seconds (subsequent HV test,
Voltage to be 60% of 2 KV, i.e. 1.2 KV for 1-2
sec.)
2.5 INSULATION RESISTANCE : > OR = 50 M Ω at 500 V DC and during rainy
days it shall be > OR = 10 M Ω (as per clause
14.3.2.2 & 3 of IRS S23 (Part-II).
2.6 CONTACT RESISTANCE : < OR = 50 mΩ measured between contact
knives.
3 MECHANICAL PARAMETERS
3.1 CONTACT PRESSURE : Make contact in full operating and break
contact
in full release position to be checked. For
parameter ref. General Specification for Relays.
3.2 CONTACT CLEARANCE : > OR = 1.5 mm.
TYPE NEUTRAL LINE RELAY 60 V DC (AC Immunised)
1 SPECIFICATION
1.1 RELAY TYPE : TMA 1144/111 IM - GUM
TMA 1153/111 IM - GUM
TMA1162/111 IM - GUM
1.2 RELAY RATINGS : 60 V DC + OR - 20%.
1.3 CONTACT CONFIGURATION : 4F/4B ; 5F/3B & 6F/2B.
1.4 RELAY MOUNTING : With or without plug-in-base & with socket.
2 ELECTRICAL PARAMETERS
2.1 COIL RESISTANCE : 1720 Ω + OR - 10% AT 20° C.C.
2.2 PICK UP VALUE : < OR = 48 V DC & > OR = 20 mA.
2.3 DROP OFF VALUE : > OR = 12 V DC & 5 mA.
2.4 HIGH VOLTAGE TEST : 2 KV for sixty seconds (subsequent HV test,
Voltage to be 60% of 2 KV, i.e. 1.2 KV for 1-2sec.)
2.5 INSULATION RESISTANCE : > OR = 50 M Ω at 500 V DC and during rainy
days it shall be > OR = 10 M Ω (as per clause
14.3.2.2 & 3 of IRS S23 (Part-II).
2.6 CONTACT RESISTANCE : < OR = 50 mΩ measured between contact knives.
2.7 AC IMMUNITY LEVEL :
(1) Back contact will not break at 300 V AC applied across the coil.
(2) Front contact will not make at 750 V AC applied across the coil.
3 MECHANICAL PARAMETERS
3.1 CONTACT PRESSURE : Make contact in full operating and break contact
in full release position to be checked. For
parameter ref. General Specification for Relays.
3.2 CONTACT CLEARANCE : > OR = 1.5 mm.
Types of Relays

• NEUTRAL LINE RELAY 60 V DC (Non AC Immunised)

• NEUTRAL LINE RELAY 60 V DC (AC Immunised)

• NEUTRAL LINE RELAY 24 V DC (Non AC Immunised)

• MECHANICALLY INTERLOCKED RELAY 60 V DC

• MECHANICALLY INTERLOCKED RELAY 24 V DC

• AC LAMP PROVING RELAY FOR ‘ON’ASPECT WITH


INTERPOSING CURRENT TRANSFORMER
Types of Relays
• AC LAMP PROVING RELAY FOR ROUTE
INDICATOR WITH INTERPOSING
CURRENT TRANSFORMER
• AC LAMP PROVING RELAY FOR SHUNT SIGNAL
• WKR2 RELAY FOR POINT GROUP
• N/R RELAY FOR POINT CONTACTORUNIT
• KEY LOCK RELAY UNIT 60 V DC (AC Immunised)
• KEY LOCK RELAY UNIT 60V DC (Non AC
Immunised)
ACI Relay
 Lamp Proving Relay
• Interlocked Relay
• Neutral Relay