5 - Gas Well Testing and Analysis
5 - Gas Well Testing and Analysis
EE053-3.5-3
Gas Engineering
Outline
• Introduction
• Flow-after-flow test
• Isochronal test
• Time to stabilization
• Radius of investigation
2. Pressure-squared technique
4
Module Code and Module Title Title of Slides
Empirical Method
• Then AOF is calculated. AOF is used for these tests. AOF is maximum
rate at which the well could flow against the theoretical back pressure at
the sand face.
Module Code and Module Title Title of Slides Slide <2> of 13
Module Code and Module Title Title of Slides Slide <2> of 13
Flow-after-Flow Test
• Sometimes called gas backpressure or four-point tests, are
conducted by producing the well at a series of different
stabilized flow rates and measuring the stabilized BHFP at the
sandface.
• The stabilized rate and pressure are recorded; the rate is then
changed and the well flows until the pressure stabilizes again at the
new rate. The process is repeated for a total of three, four, or five
rates.
Module Code and Module Title Title of Slides Slide <2> of 13
Module Code and Module Title Title of Slides Slide <2> of 13
A plot of typical flow-after-flow data
9
Module Code and Module Title Title of Slides
Example 1
10
Module Code and Module Title Title of Slides
Solution
201 psia is PR (Reservoir pressure or Initial pressure)
Test 1, Pwf =196 , then PR2 - Pwf2 = (201)2- (196)2 = 1985 = 1.985*103 psia
Test 2, Pwf =195 , then PR2 - Pwf2 = (201)2- (195)2 = 2376 = 2.376*103 psia
Test 3, Pwf =193 , then PR2 - Pwf2 = (201)2- (193)2 = 3152 = 3.152*103 psia
Test 4, Pwf =190 , then PR2 - Pwf2 = (201)2- (190)2 = 4301 = 4.301*103 psia
Solve for n;
12
Module Code and Module Title Title of Slides
13
Module Code and Module Title Title of Slides
Exercise 1
14
Module Code and Module Title Title of Slides
Exercise 2
• Isochronal tests are modelled exactly; modified isochronal tests are not.
However, modified isochronal tests are used widely because they save
time and money and because they have proved to be excellent
approximations to true isochronal tests.
23
Module Code and Module Title Title of Slides
Modified Isochronal test
24
Module Code and Module Title Title of Slides
Isochronal
Modified
Isochronal
25
Module Code and Module Title Title of Slides
26
Module Code and Module Title Title of Slides
Exercise 4
A modified isochronal test was conducted on a well located in a reservoir that
had an average reservoir pressure of 2050 psia. The well was flowed on four
choke sizes, and the flow rate and flowing bottom-hole pressure were
measured at 6 hours for each choke size.
An extended test was conducted for a period of 72 hour at a rate of 9.0
MMscfd, at which time Pwf was measured at 1270 psia. Using the data in the
following Table, calculate the values of n and C for the deliverability equation,
AOF, and flow rate for Pwf = 850 psia. Generate an IPR curve for this well.
28
Module Code and Module Title Title of Slides
Inflow Performance Relationship
(IPR)
• The inflow performance/deliverability is a measure of the
reservoir’s ability to produce gas to well bore.
29
Module Code and Module Title Title of Slides
IPR
30
Module Code and Module Title Title of Slides
• Eqn. reveals that a plot of (P 2) = P 2R — P2wf versus qsc on log-
log scales should result in a straight line having a slope of 1/n.
31
Module Code and Module Title Title of Slides
32
Module Code and Module Title Title of Slides
By taking various Pwf values, the corresponding q (gas flow rates) can
be calculated and then plotted.
33
Module Code and Module Title Title of Slides
Pressure Transient Analysis
• Also known as Well Test Interpretation or Well Test Analysis.
41
Module Code and Module Title Title of Slides
Radius of Investigation
• Defined as the point in the formation beyond which the
pressure drawdown is negligible, is a measure of how far a
transient has moved into a formation following any rate
change in a well.
Solution:
Time to stabilization is:
44
Module Code and Module Title Title of Slides
Exercise 5
k = 5.014 mD
Pr = 3500 psia
Φ = 0.1113
μg = 0.02350 cp
re = 1800 ft
t = 152.4 hr
47
Module Code and Module Title Title of Slides
Figure.4.9 Types, limitations, and uses of deliverability
48 tests.
Module Code and Module Title Title of Slides
Modified Isochronal Test