2 Temperature - Transmitters TYA
2 Temperature - Transmitters TYA
2 Temperature - Transmitters TYA
Temperature Transmitters
YSA-CO
John Freddy Baron.
4/6/20
• Reliable Dual
Compartment housing
• Simple and Safe wiring
• 4 to 20 mA
Data
1990 2000
ANALOG DIGITAL
| Product Presentation for YTA |
© Yokogawa Electric Corporation
Users’ Expectation
• Basic Diagnostics
| Document
| Product
Number|
Presentation
February
for YTA
29, 2016
| |
Copyright
© Yokogawa
© Yokogawa
Electric
Electric
Corporation
Corporation
6
Family Overview
Development policy
Development
Yokogawa own development product
Satisfy all requirements
HART 7, SIL2, NAMUR, LPS display, Variety of protocols
Factory cost down
Improvement of L/T
Product reliability and quality assurance
New-YTA
Quality comes first
New
| Product Presentation for YTA |
© Yokogawa Electric Corporation
MS Code
For HART
Factory setting Item order instruction name Default value Note
in GS
Sensor type SENSOR 1 TYPE Sensor1: Pt100 3-wire Explanation detail in
SENSOR 2 TYPE Sensor2: non-connection next slide
Calibration range and RANGE (1) 0 to 100 °C
unit RANGE (2)
Tag Number TAG NO. (blank)
Software tag SOFTWARE TAG Same as “Tag Number”
Sensor backup SENSOR BACKUP Disable
Damping time --- 2 sec Cannot specified
Sensor burnout --- High (110%) Except option C1, C2
or C3 is specified
Output in transmitter --- High (110% or more)
failure
For FF
Factory setting order instruction name Default value Note
Item in GS
Sensor type SENSOR 1 TYPE Sensor1: Pt100 3-wire Explanation
SENSOR 2 TYPE Sensor2: non-connection detail in next
slide
Calibration range RANGE (1) Sensor1: 0 to 100 °C
RANGE (2) Sensor2: non-connection
Units of
calibration range
Output mode OUTPUT MODE(1) Direct
OUTPUT MODE(2)
Output scale SCALE-1 Sensor1: 0 to 100%
SCALE-2 Sensor2: non-connection
Output scale unit
Tag Number TAG NO. (blank)
Software Tag SOFTWARE TAG TT1001
Node address NODE ADDRESS (HEXADECIMAL) 0xF3
Operation function OPERATION FUNCTIONAL CLASS BASIC
class
Sensor backup SENSOR BACKUP Disable
Custom TC Sensor
Table
TC Short
Adapt to NE89 additional, optional requirement 6.1
Para detectar un cortocircuito en los brazos de un termop
ar antes de su punto de medición.
Genera una alarma corta de sensor cuando la resistencia de líne
a del bucle de medición está por debajo del valor de umbral.
Tipo de sensor aplicable: TC
Ajuste de parámetros: valor de umbral para S1 y S2
Alarma generada: Sensor1 / 2 corto (AL.12 / 13)
Line resistance
Alarm
threshold
Operating time
threshold
Operating time
Operating time
Deference between
threshold
Sns1 and 2
Operating time
Measurement temperature
EX) Cycle number of time setting to 2
Alarma generada: AL.26 / 27
Upper limit
Lower limit
Operating time
Ultimate
YTA710
Price
Essential
YTA610
Low Cost
High
Performance / Functionality