ClorTec product

overview
De Nora Water Technologies

7
Benefits of on-site generation

Three common consumables combined to produce chlorine equivalent disinfection solution


Salt, water and electricity
Reliable and safe alternative disinfection treatment method
On-demand production
Non-hazardous chemical (feed or product)
Eliminates the need for risk management planning requirements surrounding chlorine gas
Cost-effective and proven treatment method
Reduce formation of Disinfection By-products and improves water quality
Reduced operational costs
Consistent solution strength

8
De Nora Water Technologies
ClorTec® Product Range

ClorTec® on-site sodium hypochlorite generation systems range in capacity from 1 kg/day to
1,360 + kg/day

 SCT  MCT  CT  HCT


 2 - 4 lb/day  12 -36 lb/day  75 - 300 lb/day  450 - 3000+ lb/day
 1 - 2 kg/day  5 - 16 kg/day  34 - 136 kg/day  204 - 1,360+ kg/day

9
ClorTec® System Components
ClorTec® on-site sodium hypochlorite generator
Electrical control panels
Power distribution panel
Transformer/Rectifier
Water softener
Water chiller
Brine tank
Sodium hypochlorite storage tank
Hydrogen dilution system
Chemical dosing system
Some components are optional and based on application specific requirements.
10
De Nora Water Technologies
ClorTec® Basic Reaction
Salt + Water + Electrical Energy = Sodium Hypochlorite + Hydrogen
NaCl + H2O + 2E = NaOCl + H2

For each kg. equivalent of Cl2: Site-specific water quality and temperature
factored into design
Salt (NaCl) 3 kg
Ensures system operation at optimum
Softened Water 125 litres
conditions, maximizing electrode life
Electrical energy 4.4 kWh and delivering the highest quality
water
For each kilogram of Cl2 equivalent produced
Guaranteed 0.8% solution strength
125 litres of 0.8% concentration sodium
hypochlorite
1/35 kg. of H2 gas produced

11
De Nora Water Technologies
Softened Water Requirements
Softened Water
Inlet Water Temperature: between 11˚C - 18˚C
Inlet Water Pressure: Minimum 1.4 bar (2.8 bar for HCT-600 and larger), maximum 3.5 bar
Must be free of polymer additives, flocculants, coagulants and antiscalants
pH 6.5 to 8.5
Hardness [Ca/Mg] < 10 ppm (at outlet of water softener)
Total organic content < 1 ppm
Iron <200 ppb
Manganese <10 ppb
Nickel <5 ppm
Fluoride <2 ppm
Copper <5 ppb

12
De Nora Water Technologies
ClorTec® Generation Process

Influent water passes through water softener to reduce hardness


Reduces scaling of electrodes and lengthens intervals between cleanings
Using softened water, salt is dissolved and forms concentrated brine solution
Diluted brine solution passed through electrolytic cell that uses DC current from a rectifier
Electrolyzes diluted brine into a 0.8% solution of sodium hypochlorite
0.8% hypochlorite solution flows into storage tank
Hydrogen is safely vented to the atmosphere

13
De Nora Water Technologies
ClorTec® Control Description

Fully automated batch process prompted by storage tank level


System operation only allowed if the following conditions are true
Hydrogen Dilution System is in operation
All valves and switches are in the “run” position
Transformer/rectifier is providing the correct output
If the system sees a problem, then an alarm is generated to alert the operator

14
De Nora Water Technologies
Safety Devices - Part Of Every Design

On-site sodium hypochlorite generator safety Peak overload detector

Pressure Relief Valve Thyristor over temperature

Flow Switch Transformer over temperature

High/Low Temperature Fan overload

Level Switch Current limiting semiconductor fuses


with indicators
Hydrogen management system
Control circuit fusing
Dilutes H2 to less than 25% of LEL

Transformer/Rectifier safety

15
De Nora Water Technologies
Electrolytic Cell Advantages
Clear acrylic casing provides for visual inspection of
the electrodes
Proprietary rare earth metal oxide coating
Electrolytic Cell
Provides higher conversion efficiency vs. competitive
electrodes

Bipolar configuration reduces separate parts in


electrolytic cell
Reduced chlorate and DBP’s compared to competitor Vertical Plate Design

elements and bulk hypochlorite


Vertical plate design reduces fouling

Bipolar Plate Design


16
De Nora Water Technologies
Rectifier Advantages

Rated 100% continuous duty from subzero to 50oC ambient


Rectifier designed for 100% continuous load
Heavy duty flex cable connections
Sophisticated firing control strategy
Over Voltage Protection
Over Current Protection
Transformer Over temp
Constant voltage and current +- 1%

17
De Nora Water Technologies
Enhanced Reaction & Guaranteed Efficiency
Enhanced proprietary electrode coating developed 2004
Provides greater operational efficiency
Significantly reduces consumption of salt and electricity
Reduced salt consumption to as low as 3.0 kg/kg of chlorine equivalent
Reduced energy consumption to as low as 4.4 kW/kg of chlorine equivalent
Performance guarantee offered on enhanced efficiency ClorTec systems
Clients procure on a guaranteed whole life approach
Dedicated R&D staff focused on further enhancing process efficiency

18
De Nora Water Technologies
Benefits Of Guaranteed Efficiency
Produces a lower carbon footprint
Requires less salt, reducing salt levels in
product water and discharge to the overall
environment
Requires less salt, reducing the number of
delivery trucks on the road and lowering CO2
emissions
Fewer delivery trucks reduces dependence on
foreign oil
Increases efficiency, resulting in significant
operational savings

19
Maintenance Contracts

De Nora Water Technologies global presence ensures ability to service our


customers with maintenance contracts
A factory certified technician will visit the site and perform quarterly or yearly
maintenance on the system
Ensures that the experts are always inspecting the equipment

20
De Nora Water Technologies
Installation Photos

Bamford WTW
(1227 kg/day)

Chandler Surface WTP


(2728 kg/day)
21
De Nora Water Technologies
Installation Photos

Oakley Farm
Oro Valley (2 kg/day)
(35 kg/day)

22
De Nora Water Technologies
Installation Photos

ADWEA
40 systems: 69 – 2182 kg/day range
Olivenhain Municipal Water District
682 kg/day

23
De Nora Water Technologies
Experience
Original patents for the Dimensionally Stable Anode (DSA®)
More than 35 years of electrochlorination experience
Seawater and brine systems
Water and wastewater applications
Municipal and industrial markets
Leading electrochemical technology provider
Systems produce powerful biocides and disinfecting agents
Proven track record of global installations- more than 3,500
ClorTec® brine electrochlorination systems
SANILEC®/SEACLOR® seawater electrochlorination systems
Largest installed capacity - >14 million kg/day
108 thousand kg/day - Largest seawater installed capacity system
9 thousand kg/day - Largest brine installed capacity system

24
De Nora Water Technologies
Offering

Application Product/Brand
Water & Wastewater Disinfection ClorTec®
Inland Power & Industrial Biofouling Control ClorTec®
Power & Coastal Industry Biofouling Control SEACLOR®
Desalination Water Disinfection SEACLOR®
Biofouling Control SANILEC®
Marine Sewage Treatment OMNIPURE™
MARINER OMNIPURE®
Ballast Water Management BALPURE®

25
De Nora Water Technologies
ClorTec® Unique Offering

Key advantages
Most experienced
Proven track record
Proven as the most efficient system
The largest installed base
Lowest life cycle cost of any system
Unmatched service capabilities
Leading the R&D of the next generation cells
Provides the lowest risk to benefit factor
Best value for your money

26
De Nora Water Technologies
Applications
Municipal:
Potable water disinfection
Wastewater disinfection
Water reuse disinfection
Industrial:
Swimming pool disinfection
Odor control/corrosion control
Food and beverage processing
Cooling towers biofouling control
Irrigation system disinfection
Agriculture and farming disinfection
Other industrial processes