33 KV GIS Panel - SIEMENS
33 KV GIS Panel - SIEMENS
33 KV GIS Panel - SIEMENS
Railway
Primary distribution
Generator level and high-voltage grid
G
Primary
8DA/B NXPLUS NXPLUS C NXPLUS C distributio
Wind x n level x
up to 40.5 kV, up to 40.5 kV, up to 24 kV,
up to 40 kA, up to 31.5 kA, up to 31.5 kA, up to 36 kV,
up to 5000 A up to 2500 A up to 2500 A up to 25 kA,
x x x x x x x
up to 1000 A
Secondary distribution
Secondary
distribution
level
Low-voltage compartment
Installation of secondary
devices
Busbar housing
Operating mechanism for Light-metal vessel
three-position switch
Disconnector and earthing
switch
Circuit-breaker housing
Operating mechanism Light-metal vessel
for circuit-breaker
Vacuum switching
technology
Cable connection
Inside-cone system
Busbar housing
Low-voltage compartment Light-metal vessel
Installation of secondary
devices
Three-position switch
Operating mechanism for housing
three-position switch Light-metal vessel
Disconnector and earthing
switch
Operating mechanism
Circuit-breaker housing
for circuit-breaker
Light-metal vessel
Vacuum switching
technology
Cable connection
Inside-cone system
Low-voltage compartment
Installation of secondary
devices
Busbar housing
Operating mechanism for Light-metal vessel
three-position switch
Disconnector and earthing
switch
Circuit-breaker
housing
Operating mechanism Light-metal vessel
for circuit-breaker
Vacuum switching
technology Cable connection
Inside-cone
system
E
Current Ring-core current transformers
transformer
• Main circuit as primary part
Fitted at busbar
without dielectric and thermal
problems
• Secondary part accessible
Current outside the enclosure without
C1
C1 transformer danger
C2
Fitted at cable • Free of dielectrically stressed
housing
cast-resin parts
D Current
transformer
Fitted at cable
Voltage
Transformer
Fitted at busbar
Type 4MT3
Voltage transformer
Type 4MU4 • Single-pole insulated
• Metal-enclosed
• Plug-in type
• At the busbar:
Surge-proof for 80 % UP
Voltage
Transformer repeat test with connected
Fitted at cabel transformer
housing
Type 4MT7
Type 4MU3
Example 8DA10
Example 8DA10
L3 L2 L1
Replacement of panels is
Single-phase enclosure
possible, while busbar is under
high voltage operation
2 Compartments
6 Vessels
Operational availability
Hermetically sealed system,
insensitive to aggressive ambient
conditions such as salt and water,
humidity, dust and temperature
Maintenance-free design
Ring-core current transformers –
without dielectric stress
Metal-enclosed & metalized voltage
transformers
Shielded cable terminations
Extremely low failure rate, high mean
time between failure (MTBF)
• Defined reaction
Relative pressure
• Low pickup pressure in the vessel
Vessel bursting pressure
in hPa
*)
Maintenance-free
*) Example 8DA10
CLOSED OPEN
Maintenance-free
Switch positions CLOSED, OPEN,
EARTHED or READY-TO-EARTH
OPEN: Main circuit open between
busbar and circuit-breaker: Test
voltages for isolating distances are
withstood
READY-TO-EARTH: Contact
blades connected with the earthing
contact
EARTHED: Feeder earthed and
short-circuited by closing the
circuit-breaker
EARTHED
*) Example 8DA10
According to EN 50181
Fully insulated, therefore safe-to-
touch and climate-independent
System-conforming installation of
surge arresters
System-conforming installation of
voltage transformers
Note:
1 socket might be required for cable testing
Therefore:
Maintenance-free for lifetime
No cleaning of live parts
No failures caused by small animals
Independent of site altitude
Independent of climatic conditions
No measures against condensation
Type tests:
Dielectric tests
Partial discharge tests
Temperature-rise tests
Short-time withstand current and
peak withstand current tests
Verification of making and breaking
capacity
Mechanical function tests
Verification of degree of protection
IP
Pressure withstand test for gas-
filled compartments
Test of performance with internal
faults
Climatic tests
Routine tests
High-voltage test on main circuits
Voltage test on auxiliary and
control circuits
Measurement of the resistance of
the main circuit
Partial discharge measurement
Mechanical function test
Pressure withstand test of gas-
filled
compartments
Tightness test of gas-filled
compartments
Test of auxiliary electrical
equipment
Wiring test
Kulmbach / Germany
8DA10
16 panels
24 First
kV / SIEMENS
16 kA (3s) / 1250 A
gas-
insulated
medium-voltage switchgear
(April 1982)
Tibet / China
8DA10
205 panels
GECOL / Libya
1398 panels
36 kV / 40 kA (3s) / 2500 A
8DB10
117 panels
Benefits at glance