03 - Structural Design Procedure
03 - Structural Design Procedure
1/18/2020 2
The structural designer must learn to
arrange and proportion the parts of his
structures so that they can be practically
erected and will have sufficient strength
and reasonable economy.
These important items, called safety, cost
and practicality, are briefly discussed in
the following slides.
1/18/2020 3
1. The structure must safely support the
loads to which it is subjected.
1/18/2020 5
Designers should learn everything possible
about the detailing, the fabrication, and the field
erection of steel besides the loads, mechanics,
and the expected material strengths.
The designer must have information
concerning the transportation of the materials to
site, labour conditions, equipment for erection,
problems at site, field tolerances and the
required clearances at the site.
This knowledge helps to produce reasonable,
practical and economical designs.
1/18/2020 6
Procedure Of The Structural Design
The structural framework design is the
selection of the arrangement and sizes of
structural elements so that service loads
may be safely carried.
1/18/2020 7
Collect and list all the known data
1/18/2020 8
The complete design procedure for a whole
structure requires iterations and the main
steps are listed below:
1/18/2020 10
4. The Loading conditions are considered
and the loads to be carried by the structure
are estimated.
5. Based on the decisions of earlier steps,
trial selection of member sizes is carried
out depending on thumb rules or assumed
calculations to satisfy an objective criterion,
such as least weight or cost.
1/18/2020 11
6. The Structural analysis involving modelling
the loads and the structural framework to
obtain internal forces stresses and
deflections is carried out.
7. All strength and serviceability requirements
along with the predetermined criteria for
optimum are checked.
If any check is not satisfied, the member
sizes are revised.
This stage is called evaluation of the trial
member sizes.
1/18/2020 12
8. Repetition of any part of the above
sequence found necessary or desirable as
a result of evaluation is performed in this
stage called redesign.
9. The rivets, bolts and welds along with other
joining plates and elements are designed.
The process is termed as the design of
assembly and connections.
1/18/2020 13
10.It is determined whether or not an
optimum design has been achieved, and
the final decision is made.
11.Drawings are prepared to show all design
details.
An estimate for the required quantities is
also made.
This stage of design is called preparation
of design documents.
1/18/2020 14
LOAD FACTORS AND
LOAD COMBINATIONS
It is almost impossible that all loads like live load,
snow load, wind load and earthquake all occur
together with their maximum intensity.
A load combination combines different types of loads
depending on the probability of occurrence of these
loads acting simultaneously, considering their
expected intensity in the combination compared with
the maximum load intensity.
1/18/2020 15
The factors of safety are also included in the
LRFD load combinations and hence the
output of the expressions is a design load.
The alphabets used in the combinations
mean different types of nominal service loads
and the numerical values with them are the
load factors.
When intermediate floors have full live load,
any type of roof load may be considered
equal to half of its normal service load
intensity.
1/18/2020 16
Similarly, in case of maximum intensity wind storm,
live load may be half.
The last combination, given afterwards, is very
important for uplift of structure or reversal of forces.
The wind load on roof is upwards in majority of the
cases and if the downward gravity load is less, the
structure may be blown up or sagging bending may
change into hogging bending.
A list of most commonly used combinations are as
under:
1/18/2020 17
LRFD Load Combinations
1/18/2020 18
ASD Load Combinations
The simplified ASD load combinations are as
follows:
1. D
2. D+L
3. D + Lr
4. D + 0.75L + 0.75Lr
5. D + 0.8W
6. D + 0.6W + 0.75L + 0.75Lr
7. 0.6 D + 0.8W
1/18/2020 19
TYPES OF STRUCTURAL STEEL
1/18/2020 20
E-value for steel = 185 GPa to 230 GPa
(Average 200 GPa)
1/18/2020 21
Most of the structural steel falls into the mild carbon
steel or simply mild steel (MS) category.
Hot rolled structural shapes may be made to
conform to A36M, A529M, A572M, A588M, A709M,
A913M and A992M.
Sheets are manufactured according to the standards
ASTM A606, A1011MSS, HSLAS and HSLAS-F.
Bolts are made according to ASTM standards A307,
A325M, A449, A40M and F1852.
1/18/2020 22
Most commonly used structural steel is A36M
having the following properties:
Fy = 250 MPa
Fu = 400 MPa
E = 200 GPa
Weld electrodes are classified as E60, E70, E80,
E100 and E110. The letter E denotes electrode.
The two digits indicate the ultimate tensile strength
in ksi. The corresponding SI equivalents are E425,
E495, E550, E690, E690 and E760.
1/18/2020 23
HOT ROLLED STRUCTURAL SHAPES
1/18/2020 24
Slope 0o 16.7% Slope
Thicker than
flange
16.7% Slope
1/18/2020 25
Bars
1/18/2020 26
1. W Shapes
Web
1/18/2020 29
* Doubly symmetric I-shapes.
* Previously called standard I-beams or
American Standard Beams.
* The inner edge of the flange has a slope of
approximately 16.7.
* An S510 x 112 section means that the section
is S-shape having nominal depth of 510 mm
and weight of 112 kgf/m.
* The width / depth ratio varies from about 0.25
to 0.85.
1/18/2020 30
3. M Shapes
* Miscellaneous I-shapes.
* Doubly symmetric I-shapes not classified as
W or S shapes.
* Relatively lightweight used for smaller spans
and lesser loads.
* An M310 x 17.6 means that it is M-shape
section having nominal depth of 310 mm and
weight of 17.6 kgf/m.
1/18/2020 31
4. C Shapes
16.7
1/18/2020 32
* Channel shapes with standard
proportions.
* Inner flange slope is the same as that
for the S shapes (16.7).
* Previously called Standard or
American Standard Channels.
* A C150 x 19.3 is a standard channel
shape with a nominal depth of 150mm
and a weight of 19.3 kgf/m.
1/18/2020 33
5. MC Shapes
These sections have the following properties:
* Channels not classified as C-shapes.
* Previously called Shipbuilding or
Miscellaneous Channels.
6. L Shapes or Angle Sections
The various types of angle sections are shown
in Figure 1.6 and their salient features are
given below:
1/18/2020 34
a
1/18/2020 36
2L89 x 76 x 12.7 means two angles 2L89 x
76 x 12.7 placed side by side in one of the
ways shown in the figure.
7. T Shapes
1/18/2020 37
* These are called structural tees.
* These are obtained by splitting W, S or
M shapes and are called WT, ST or MT
shapes, respectively.
* A WT205 x 30 is a structural tee with a
nominal depth of 205mm and a weight
of 30 kgf/m and is obtained by splitting
the W410 x 60 section.
1/18/2020 38
COLD - FORMED SHAPES
1/18/2020 39
Channels Zees I-Shaped Double Angle
Channels
Hat Sections
1/18/2020 40
BUILT-UP SECTIONS
Sections made by combining two or more standard
hot rolled sections, joined together at intervals with the
help of direct welding, stay plates or lacing, are called
built-up sections.
Examples are four angles section, double angle
section and double channel section shown in Fig. 1.9.
However, double angle section is sometimes excluded
from built-up section category and is considered as a
regular hot rolled member because of difference of its
behaviour from other built-up sections.
1/18/2020 41
4-Angle Box
Section
1/18/2020 42
CLADDING
1/18/2020 43
End of this file
1/18/2020 44