BIM TO FIM Stanford Health Care

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 41

WELCOME

1
AGENDA

WMU Fast Facts

Why use BIM for new


& existing buildings

BIM for new


construction

BIM for existing


buildings

2
WMU FAST FACTS

Doctoral High Research

Established in 1903

25,000 students

1,200 acres

8 million square feet of University space

On-campus residence halls and apartments


are able to house 5,500 students
151 Buildings

3
WMU FAST FACTS

FM – 500 employees

Central Heat and Power Plant Co - generation

39 miles of sidewalk and 26.5 lane miles of


roadway

Over 100 Miles of Underground Infrastructure

4
WHY USE BIM FOR
NEW & EXISTING BUILDINGS
Reduce the time and frustration obtaining
critical facility information from files and
spread sheets

Eliminate physical obstacles and barriers to


obtaining information from field verification

Remote access to all critical facility information


(Whenever, Wherever, However…)

Common depository for all facility information


stored and retrieved via a virtual/geo-
referenced application

5
BIM FOR NEW CONSTRUCTION

6
CAPITAL CONSTRUCTION PROJECTS

Stryker School
of Medicine
$ 68 Million
Dining Facility
$ 36 Million

Western
East Hall
Heights
$ 21 Million
$ 48 Million

Sangren Hall
$ 60 Million

Zhang Legacy
Collections Center
$ 8 Million

7
BIM PLANNING
Setting expectations for all parties on the front end
BIM PROJECT EXECUTION PLAN: WHAT’S IN IT?

1. PROJECT GOALS / BIM USES

8
BIM EXECUTION PLAN
1. BIM Goals and uses
PRIORITY
(HIGH/ MED/ GOAL DESCRIPTION PROJECT PHASE
LOW)
H Provide WMU a LOD 300 model including Arch, MEP, and Structure for construction Construction
H Coordinate all disciplines through the design/construction process to reduce RFI’s Construction
M Reference all building components per the Western Michigan University BIM guideline Lifecycle
H Improve commissioning process by adding equipment information into BIM process Lifecycle
H Improve visualization of design intent using BIM design principles Design

X PLAN X DESIGN X CONSTRUCT X OPERATE


SITE UTILIZATION BUILDING MAINTENANCE
PROGRAMMING X DESIGN AUTHORING
PLANNING SCHEDULING
CONSTRUCTION SYSTEM BUILDING SYSTEM
SITE ANALYSIS X DESIGN REVIEWS X
DESIGN ANALYSIS
X 3D COORDINATION X 3D COORDINATION X ASSET MANAGEMENT
SPACE MANAGEMENT /
X STRUCTURAL ANALYSIS X DIGITAL FABRICATION X
TRACKING
3D CONTROL AND
LIGHTING ANALYSIS DISASTER PLANNING
PLANNING
ENERGY ANALYSIS RECORD MODELING RECORD MODELING

MECHANICAL ANALYSIS

OTHER ENG. ANALYSIS


SUSTAINABLITY (LEED)
EVALUATION
CODE VALIDATION
PHASE PLANNING PHASE PLANNING PHASE PLANNING PHASE PLANNING
(4D MODELING) (4D MODELING) (4D MODELING) (4D MODELING)
X COST ESTIMATION X COST ESTIMATION X COST ESTIMATION COST ESTIMATION

9
BIM EXECUTION PLAN
2. Collaboration Procedures: how often to share? How?

• BIM Coordination Meeting Procedures

Meeting type Project stage Frequency Participants Location


BIM REQUIREMENTS KICK-
PROGRAMMING ONCE WMU/AE/CONST WMU
OFF
BIM EXECUTION PLAN
PROGRAMMING ONCE RESPONSIBLE PARTY WMU
DEMONSTRATION

DESIGN COORDINATION DD/SD/CD BI-WEEKLY RESPONSIBLE PARTY WMU

CONSTRUCTABILITY
CONSTRUCTION BI-WEEKLY RESPONSIBLE PARTY WMU
COORDINATION

LIFECYCLE BIM PLANNING CONSTRUCTION AS-NEEDED RESPONSIBLE PARTY WMU

10
BIM EXECUTION PLAN
3. File naming convention

145_struct_03455.steel frame north elevation_approved_2010 11

Field 1 Field 2 Field 3 Field 4 Field 5


Location Sub-Location Project # . Description Doc Revision Date

Building #, Bid, RFP, RFQ 6895 CD, DD, SD, Sheet #, 2009 11 09
Admin, Proposal, 9-45 As built, Rev #, Req # 2008
Concepts, Budget, 8489 Bid set, Reviewed, 2006 10
Landscape, Transmittal, Sheet title, Approved,
Package
Underscore _

Underscore _
Approved as
Underscore _

Underscore _
Maps, Memo,
Master plan, System: title, Noted,
Period .

Site, Elect Subject, Rejected,


Study, Mech Shop dwg Addendum,
Utilities… Arch title… Owner redline,
Struct Review,
Plumb Owner review
Steam…

11
BIM EXECUTION PLAN
4. Technology infrastructure requirements

Project participants must have certain software in order to participate in the BIM
process.

BIM use discipline software version

ARCH  Revit Architecture 2016

MEP  Revit MEP/AutoCAD MEP 2016


Design
Authoring STRUCT  Revit Structure 2016

CIVIL  Civil 3D 2016

Coordination CONSTRUCTION  Naviswork Manage 2016

Owner LIFECYCLE  Naviswork Manage 2016

12
BIM EXECUTION PLAN
5. Delivery Strategy & LOD – Level of Development

LOD 100 Conceptual Modeling LOD 200 General Modeling


“Guesstimate” “Specify it”

LOD 300 Accurate LOD 400


Modeling Fabrication
& Shop Drawings LOD 500 M & O
& Assembly
“Buy it” “Maintain it”
“Build or Install
it” 13
BIM EXECUTION PLAN
5. Delivery Strategy & LOD – Level of Development

Architects
Engineers

General Sub-
Contractor contractors

Revit
Model
Interaction with the
Revit model

WMU
Level of Detail
500
Revit Model(s)
14
BIM EXECUTION PLAN
Building information model requirements Lifecycle BIM

Specific list of Information (parameters) required to be attached to the BIM model


PACKAGE AIR HANDLING

WMU_TAG # WMU_TAG #
WMU_TAG #
WMU_TYPE DESC WMU_TYPE DESC
WMU_TYPE DESC
WMU_SUBTYPE DESC WMU_SUBTYPE DESC
WMU_SUBTYPE DESC
Supply fans

DESCRIPTION DESCRIPTION

Return fans
DESCRIPTION WMU_LOCATION
UNITS

WMU_LOCATION WMU_LOCATION
WMU_MANUFACTURER
WMU_MANUFACTURER WMU_MANUFACTURER
WMU_MODEL # WMU_SERIAL #
WMU_MODEL # WMU_MODEL #
WMU_FILTER TYPE WMU_FILTER
WMU_SERIAL # WMU_BELT WMU_SERIAL # WMU_BELT
SIZE WMU_FILTER QUANTITY
NAME WMU_BELT SIZE NAME WMU_BELT SIZE
SEQUENCE OF OPERATION
WMU_BELT QUANTITY FAN WMU_BELT QUANTITY FAN
O&M
CURVE CURVE
SUBMITTAL

WMU_MOTOR ID
WMU_MOTOR ID
WMU_MOTOR DESCRIPTION
WMU_MOTOR DESCRIPTION
WMU_MOTOR RPM
WMU_MOTOR RPM
WMU_MOTOR HP
WMU_MOTOR HP
WMU_MOTOR MODEL #
WMU_MOTOR MODEL #
Motor

WMU_MOTOR SERIAL #

Motor
AIR DISTRIBUTION WMU_MOTOR MANUFACTURER
WMU_MOTOR SERIAL #
WMU_MOTOR MANUFACTURER
WMU_MOTOR AMPERAGE
SYSTEMS WMU_MOTOR VOLTAGE
WMU_MOTOR AMPERAGE
WMU_MOTOR VOLTAGE
WMU_MOTOR FRAME
WMU_MOTOR FRAME
WMU_MOTOR PHASE
WMU_MOTOR PHASE
WMU_MOTOR BEARING/COUPLING
WMU_MOTOR BEARING/COUPLING
SIZE
SIZE
15
TAKEAWAYS

 CREATE BIM GUIDELINE

 PSA AGREEMENT: GET IT IN THE CONTRACT!

 KICKOFF MEETING: SET EXPECTATIONS FOR ALL THE


PARTIES INVOLVED

 DETERMINE GATEKEEPER

 BIM IS A LIVING DOCUMENT

16
BIM FOR EXISTING BUILDING

College of Health and Human Services 17


BRONCO BIM

• Prints to 3D Model
1
• Adding Maintainable
Mechanical Equipment In
2 BIM

• Connecting the Model to


our CMMS-TMA
3

College of Health and Human Services 18


PRINTS TO 3D MODEL
From Existing AutoCAD floor plans to 3D Model using Autodesk Revit Platform
1995-Present
Original 1995-2000 Post-CAD era
Blueprints 31 Buildings
Standardized
2.64 million SF
Simple floor
plan
2011-2013
< 1995
Pre-CAD era 3D Model
107 Existing
Buildings
6.19 million SF

About
520 Floor
Plans

Existing building 3D Model


Sprau Tower Sprau Tower
19
PRINTS TO 3D MODEL
From Simple floor plans to 3D: Field verification and Drawings Review

Timeframe
2011-2013

Measure

Survey

Review

20
PRINTS TO 3D MODEL
From Simple floor plans to 3D: Revit Modeling
Sprau Tower
Linking each simple floor plan with the
Modeling levels and grids corresponding
Revit 3D Model levels

Original elevations 3D Model Floor levels

21
PRINTS TO 3D MODEL
From Simple floor plans to 3D: Revit Modeling

Sprau Tower
TIMELINE: 2011-2013
138 Existing buildings modeled in 3D Revit

• White-box empty rooms


• Windows & doors location
• Generic library
• Highly detailed exteriors
• NO MEP Sprau Tower, 4th floor 3D view
22
CONNECTING THE DOTS FOR
EXISTING BUILDINGS

• Adding Maintainable
Mechanical Equipment In
2 BIM

College of Health and Human Services 23


ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Types of equipment and parameter

MEP
Air Conditioning Unit
Condensing Unit
Air Handler
Air Compressor
Chiller
Centrifugal Pump
Condensate Pump
Cooling Tower
Monthly/yearly
Maintainable Exhaust Fan
Equipment Supply Fan
based on User Sump Pump
Manuals
Return Fan

24
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Types of parameter BIM PARAMETERS
20 parameters

CMMS 20 years of maintenance


experience with 9 shops and
WMU_SUBTYPE DESC
WMU_TYPE DESC
TMA 110 skilled tradespeople DESCRIPTION
WMU_TAG #
WMU_LOCATION
WMU_MANUFACTURER
WMU_MODEL #
WMU_SERIAL #
WMU_FILTER TYPE
WMU_FILTER SIZE
WMU_FILTER QUANTITY
WMU_MOTOR ID
WMU_MOTOR MODEL #
WMU_MOTOR SERIAL #
CMMS-TMA DATABASE WMU_MOTOR HP
>100 parameters WMU_MOTOR FRAME
WMU_BEARING/COUPLING SIZE
WMU_BELT NAME
WMU_BELT SIZE
WMU_BELT QUANTITY
25
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Position BIM equipment model

Mechanical Room, Schneider Hall

Equipment
Location

26
Tag #
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Creation of the Equipment Library

Search for the Equipment 3D Models (Manufacturer’s websites, Revit


Add-ins…)

Bell and gossett: http://www.catalogds.com


27
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Creation of the Equipment Library

Model the Equipment that are Custom Made or not available

Original construction drawings

3D Revit Model 28
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Creation of the Equipment Library

Model the Equipment that is Custom Made or not available

Real Model

29
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Equipment Parameters Schedule

Create a Mechanical Equipment Schedule on Revit

Revit

30
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Plugging equipment in the model
Insert Equipment Model into the Revit Model

31
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Plugging equipment in the model
Insert Equipment Model into the Revit Model

32
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Plugging equipment in the model (Mechanical Room, Schneider Hall)

Before
After

33
ADDING MAINTAINABLE MECHANICAL
EQUIPMENT IN BIM
Summary
TIMELINE: 2014 - 2016

Reality

138 2,694
existing maintainable
buildings equipment

Revit Model

College of Health and Human Services

34
CONNECTING THE DOTS FOR
EXISTING BUILDINGS

• Connecting the Model to


our CMMS-TMA
3

College of Health and Human Services 35


CONNECTING THE MODEL TO OUR
CMMS-TMA
Overall View – Moving Data Between Data Silos

BIM CMMS
55000
PIECES OF
INFORMATION

36
CONNECTING THE MODEL TO OUR
CMMS-TMA
Connecting to Revit and TMA: the Revit tool

REVIT ADD-IN “WebTMA Interface”

Logging in from Revit Logging in


from WebTMA

37
CONNECTING THE MODEL TO OUR
CMMS-TMA
Importing from TMA to Revit
The Results
From this… To this

38
TAKEAWAYS

 3D models for existing building do not need to be


highly detailed, LOD 100-200

 Define maintainable equipment and its parameters:


use tradespeople’s experience and operation manuals as reference

 Audit your CMMS data in the field while locating


your maintainable equipment

 If equipment 3D models are not available on the web,


create them using your construction documents or measurements

 Connect CMMS and BIM models

 Define standards for BIM-TMA data management

39
BIM IN FIELD

40
41