Case Study - Boiler Explosion

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 18

Case Study

on
NTPC, Unchahar Boiler Explosion
By
Satish Chavhan

Submitted to
Prof. Pavan Totla

National Institute of Construction Management &


Research, Pune
PGP PEM(2018-20)
Feroze Gandhi Unchahar Thermal Power Plant

• Installed capacity- 1,550 MW.


• Units Commissioned
Unit I : 210 MW Nov 1988
Unit II : 210 MW Mar 1989
Unit III : 210 MW Jan 1999
Unit IV : 210 MW Oct 1999
Unit V : 210 MW Sep 2006
Unit VI : 500 MW Mar 2017(COD-September 30, 2017)
MSP

SEPARATOR

ROOF TUBE
I/L Header

SEPARATOR
FRH
DRAIN TANK SH DIV FSH
Panel

LP-BP
LTSH
LTRH

HP-BP
ECO
VERTICAL WATER WALL

G LTRH I/L Header


ECO I/L Header
LPT LPT IPT HPT

CRP

CONDENSER
BRCP

A B C
CEP
DEAERATOR
GSC
A B
BFBP

A B
MD-BFP
TD-BFP

l
WW LOWER Header HP BFWP
FUEL FEEDING
MASTER FUEL TRIP(MFT)
If any of the predetermined master fuel trip condition occurs a master fuel
trip is initiated. The first out cause of trip indication is displayed and
alarmed. Conditions of a master fuel trip are:
• All FD Fans off
• All ID Fans off
• Boiler air flow low for 3 secs
• Loss of all fuel
• Loss of all flame
• Furnace pressure very high/Low
• Drum level very high/low
• Critical Flameout
• Delayed light-up
• Re-heater protection operated
On 1st November 2017 plant was running at 500MW
Ash evacuation from bottom ash hopper stopped
• Ash level increased in furnace more than 25m

• NTPC has started cutting their load to 200MW


from 500MW
• More then 30 workers started
Poking in 8 manholes (4 Hoppers)
• At the same time Higher
official bypassed MFT
Water
Wall
Leakage

Due to the heavy steam leakage pressure


Started increasing.
• Due to sudden opening at corner no-2
flue gases and steam came out
• Unburnt coal flew to second pass and
started burning near economiser
MISTAKES
 Instead of taking shut down, operation department continued
to run the unit with reduced load.
 Consent from higher officials for Master Fuel Trip
(MFT)Bypass
 6th Unit was continuously running more than 1000Hr, which
was against CEA guidelines)
 Boiler erection was completed in 30 month of record break
time.
 During running condition max 6 people required in boiler
area. (Chairman, All India Power Engineers Federation). But
more than 300 people were working at the time of accident.
 Ash level indicator was not installed in bottom ash hopper.
Continued…
 Double poking should be done after taking boiler shut
down.
 Workers working in boiler area did not have safety mask.
 There was no early warning alarm in boiler area.
 COD was done without cleaning scrap, insulation work
and painting, and same has been carried out in running
unit.
 The fire hydrant line and the detection system failed to
respond.
 Irregular soot blowing.
 Use of low grade coal.
COMMITTEE REPORT
CONSEQUENCES
 46 People died, more than 100 people injured, many contract workers are still missing.
 6th Unit boiler licence has been cancelled on 14th Nov 2017 due to irregularities in plant
Report by Delhi Solidarity Group