Simatic Product Overview: Siemens
Simatic Product Overview: Siemens
SIEMENS
SIMATIC S7 1/2 24 October 2019
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS
Objectives
SIMATIC OVERVIEW
Operating Panel
PG
PC Panel
MPI
Ethernet
ProfiBus
SIMATIC NET
ProfiBus
DP
Bus System
DP Slaves
DP/PA
Bus System
SIMATIC S7-200
SIMATIC S7-300
CPU 313C-2 DP
The compact CPU with integrated digital I/Os
and PROFIBUS DP master/slave interface.
CPU 315-2 DP
The CPU with medium to large program
memory, High processing performance in
binary and floating-point arithmetic,
PROFIBUS DP master/slave interface.
CPU 317T-2 DP
The CPU with integrated technology/motion
control functionality, For multi-sector
automation tasks in the construction of
series machines, special machines and
plants. CPU 315-2 DP
CPU 317T-2 DP
SIMATIC S7 7/2 24 October 2019
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS
SIMATIC S7-300
CPU S7-300
Signal Modules:
Digital input modules
Digital output module
Analog input modules
Analog output modules
CPU IM DI DO AI AO FM CP
Interface Modules:
The IM360/IM361 and IM365
make multi-tier configurations possible.
Function Module (FM)
- Counting
- Positioning
- Closed-loop control.
Communication Processors (CP)
- Point-to-Point connections
- PROFIBUS
- Industrial Ethernet.
Signal Modules:
Digital input modules
Digital output module
CPU DI DO AI AO
Analog input modules
Analog output modules
Memory Card
A slot is provided for a memory card. The memory
card saves the program contents in the event of a
power outage without the need for battery.
• RAM cards are available with a capacity of:
64KByte, 256KByte, 1MByte, 2MByte.
• Flash EPROM cards are available with a capacity of:
64KByte, 256KByte, 1MByte, 2MByte, 4MByte,
8MByte, 16MByte.
SIMATIC S7 9/2 24 October 2019
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS
Mode Selector:
MRES =Memory reset function (Module Reset)
STOP = Stop mode, the program is not executed.
RUN = Program execution
Status Indicators.
SF = Internal CPU fault or fault in module.
BATF = Battery fault; battery empty or non-existent.
DC5V = Internal 5 VDC voltage indicator.
FRCE = FORCE; indicates that at least one input
or output is forced.
RUN = Flashes when the CPU is starting up, then
a steady light in Run mode.
STOP = Shows a steady light in Stop mode.
SIMATIC S7-400
CPU 416-2
• High-performance CPUs in the high-end
performance range
• Applicable for plants with high
requirements in
the high-end performance range
CPU 414-4H
• Fault-tolerant automation system with
redundant configuration
• For applications with high failure safety
requirements CPU 414-4H CPU 416-2
•Processes with high restart costs, expensive
downtimes, little supervision, and few
maintenance options
• Hot standby: Automatic reaction-free
switching to the standby unit in the event of a
fault
CPU 414-4FH
• Failsafe automation system for plant with
high safety requirements
• If required, also fault tolerant through
redundant configuration
CPU 414-4FH
SIMATIC S7 11/2 24 October 2019
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS
SIMATIC S7-400
• The power PLC for the mid to upper
performance range
• Performance-graded range of CPUs
• Extensive selection of modules
• Expandable design to over 300
modules
•Backplane bus integrated in the
modules
•Can be networked with
- (MPI)
- PROFIBUS
- Industrial Ethernet
SIMATIC S7-400
Fault LEDs
LEDs for the CPU‘s statuses and faults, both internal and
external
Memory Cards
Mode Selector
MRES = Memory reset function (Module RESet)
STOP = STOP mode
RUN = Program execution, read-only access possible from PG.
RUN-P= Program execution, read/write access possible from PG.
MPI / DP Interface
DP Interface
For connecting to distributed peripherals
EXT-BATT
SIMATIC Programming
Device
Field PG
Intel Pentium M processor.
Power PG