100% found this document useful (1 vote)
535 views

Drying Examples

This document provides examples of drying calculations: 1) A hot air dryer handling 1,000 kg/h of wet feed with 20% moisture to 12.5% dry basis moisture. Using air at 82.2C exhausting at 60C, calculate air volume and preheater duty. 2) A coconut dryer processing 1,133.8 kg/h coconut meat from 20% to 1.5% moisture. Given temperatures and properties, calculate heat input. 3) A dryer handling wet material from 100% to 10% dry basis moisture using air at 100C exhausting at 60C and 52.5C dew point. Calculate ambient air volume and re-cir

Uploaded by

Isabel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
535 views

Drying Examples

This document provides examples of drying calculations: 1) A hot air dryer handling 1,000 kg/h of wet feed with 20% moisture to 12.5% dry basis moisture. Using air at 82.2C exhausting at 60C, calculate air volume and preheater duty. 2) A coconut dryer processing 1,133.8 kg/h coconut meat from 20% to 1.5% moisture. Given temperatures and properties, calculate heat input. 3) A dryer handling wet material from 100% to 10% dry basis moisture using air at 100C exhausting at 60C and 52.5C dew point. Calculate ambient air volume and re-cir

Uploaded by

Isabel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 6

DRYING

Example Problems
Example 1:
• A hot air dryer handles 1,000 kg/h of wet feed with a
moisture content of 20% wet basis to reduce the moisture
content to 12.5% dry basis. Atmospheric air at 23.9°C
with a relative humidity of 60% is preheated to a dry bulb
temperature of 82.2°C. The exhaust air leaves the dryer
at 60°C. Calculate: (a) the volume of the atmospheric air
handled by the preheater and (b) the duty of the preheater
in kcal/h.
Example 2
• A Proctor & Swartz coconut meat dryer processes 1,133.8 kg of
coconut meat per hour. The following are other data:

• Specific heat of coconut meat = 0.754 kJ/kg·K


• Density of coconut meat from the shearing and washing section =
1.520 kg/m3
• Initial moisture content of coconut meat = 20%
• Final moisture content of coconut meat = 1.5%
• Coconut meat inlet temperature = 21°C
• Coconut meat outlet temperature = 38°C
• Drying condition = 71°C db
• Drying condition RH = 20%
• Barometer reading = 89.6 kPa

• Compute the heat input to the dryer.


Example 3
• A wet material from a processing plant containing 100%
(dry basis) moisture has to be dried to produce a product
with 10% (dry basis) moisture. Heated air at 100°C and
10% relative humidity is being supplied to the dryer and
leaves at 60°C and a dew point of 52.5°C. Part of the
outlet air is re-circulated and mixed with ambient air at
30°C and 70% relative humidity. Neglecting heat losses
due to radiation to the surroundings and pre-heating of
the solid materials and its receptacle, calculate:
• (a) Volume of ambient air, m3/min
• (b) Percentage of the outlet air re-circulated and mixed
with ambient air when producing 500 kg/h of product.
Seatwork
• Ten short tons/h of crushed coal with 15.1% moisture (wet
basis) is to be dried to 5% moisture (wet basis) in a
counter-current continuous rotary dryer using hot air
entering the dryer at 180°F, 10% relative humidity and
leaves at 40% RH. How much hot air, in ft3/min, will be
needed for the operation? Assume adiabatic operation.
Seatwork
• An adiabatic tunnel dryer reduces the moisture content of pineapple stumps used
as a fuel in the boiler of a pineapple cannery. Ambient air is heated and blown
through the tunnel dryer countercurrent to the flow of pineapple stumps. The
operating conditions are:

• Pineapple Stumps:
• Feed rate 100 MT/day
• Moisture content, feed 100% Dry basis
• Moisture content, product 30% dry basis
• Ambient Air:
• Temperature 29.4°C
• Relative Humidity 80%
• Hot Air:
• Inlet temperature 76.9°C
• Outlet relative humidity 100%

• Calculate: (a) the quantity of moisture removed from the pineapple stumps in
MT/day; (b) the humidity of the inlet air; (c) the temperature of the air leaving the
dryer; (d) the volume of ambient air needed for drying in m3/h

You might also like