DP Flow Measurement: Naufal Muthahhari
DP Flow Measurement: Naufal Muthahhari
Naufal Muthahhari
Outline
• Introduction
• Principles of Fluid Flow in Pipes
• Reynolds Number
• Discharge Coefficient & Gas Expansion Factor
• Rosemount DP Flow Primary Element
• 1495
• 1195
• 1595
• Compact Orifice Flow meter
• Straight Pipe Run Requirement
Introduction
Safety Custody
• DP Flowmeter is the most common flow technology Applications Transfer
to determine flow of fluid in industrial piping
• DP Flow technology uses primary element and
secondary element to calculate flow
• DP Flow measurement can be utilized to optimize
many aspects of a process Production
Efficiency
Principles of Fluid Flow in Pipes
Fluid Mechanics
Fluid Kinematics The study of fluids in Fluid Dynamic The study of the effects
motion (Rd) of forces due to fluid motion (Cd, Y1, DP,
Vena Contracta, Pressure Loss, Swirl)
Specification
Max Operating Pressure ANSI B16.5 2500#
Process Temperature Range -320 to 1200 °F (-196 to 649 °C)
Fluid Type Liquid, gas, steam
Temperature limit
Quadrant
Segmental
Restriction Orifice
Specification
Max Operating Pressure ANSI B16.5 900#
Process Temperature Range -148 to 554°F (-100 to 285 °C)
Fluid Type Liquid, gas, steam
Specification
Max Operating Pressure ANSI B16.5 2500#
Process Temperature Range -320to 1200°F (-196 to 649 °C)
Fluid Type Liquid, gas, steam
Rangedown Up to 100:1 (5:1 flow turndown) Up to 150:1 (8:1 flow turndown) Up to 200:1 (14:1 flow turndown)
Measurement Range Up to 1000 inH2O (2,48 bar) Up to 1000 inH2O (2,48 bar) Up to 1000 inH2O (2,48 bar)
differential differential differential, Up to 3626 psia (250,00
bar) absolute, Up to 3626 psig (250,00
bar) gage
Line Size 0.5 to 12 in. (15 to 300 mm) / 0.5 to 0.5 to 12 in. (15 to 300 mm) / 0.5 to 0.5 to 12 in. (15 to 300 mm) / 0.5 to 1.5
1.5 in. (15 to 40 mm) 1.5 in. (15 to 40 mm) in. (15 to 40 mm)
Output Differential pressure, scaled variable Differential pressure, scaled variable Differential pressure, static pressure,
process temperature, scaled variable,
mass flow, volumetric flow, energy flow
Communication Protocol 4-20 mA HART®, WirelessHART®, 4-20 mA HART®, WirelessHART®, 4-20 mA HART®, WirelessHART®,
FOUNDATION™ Fieldbus, PROFIBUS®, FOUNDATION™ Fieldbus, PROFIBUS®, FOUNDATION™ Fieldbus
1-5 V Low Power HART® 1-5 V Low Power HART®
Process Wetted Material 316 SST 316 SST 316 SST
Diagnostics Basic Diagnostics Basic Diagnostics, Loop Integrity Basic Diagnostics, Loop Integrity,
Process Intelligence, Plugged Impulse
Line
Accuracy & Stability Up to ±1.65 percent flow rate See catalogue
up to ±2.25% flow rate accuracy, 5:1
accuracy, 8:1 flow turndown, 10-year
flow turndown, 3-year stability
stability
Compact Integral Orifice Accuracy
Straight Pipe Requirement
Straight Pipe Requirement (2)