GLP or Good Laboratory Practices

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 35

GLP or

Good Laboratory Practices


GLP: GOOD LABORATORY
PRACTICE
 GLP is an FDA regulation.
 Definition: GLP embodies
a set of principles that
provides a framework
within which laboratory
studies are planned
performed, monitored,
reported and archived.
 GLP is sometimes confused
with the standards of
laboratory safety like
wearing safety goggles.
HISTORY
 GLP is a formal regulation that was created by the
FDA (United states food and drug administration) in
1978.
 Although GLP originated in the United States , it had
a world wide impact.
 Non-US companies that wanted to do business with
the United states or register their pharmacies in the
United States had to comply with the United States
GLP regulations.
 They eventually started making GLP regulations in
their home countries.
 In 1981 an organization named OECD (organization
for economic co-operation and development )
produced GLP principles that are international
standard.
WHY WAS GLP CREATED?
 In the early 70’s FDA became
aware of cases of poor laboratory
practice all over the United States.
 FDA decided to do an in-depth
investigation on 40 toxicology
labs.
 They discovered a lot fraudulent
activities and a lot of poor lab
practices.
 Examples of some of these poor
lab practices found were
1. Equipment not been calibrated to
standard form , therefore giving
wrong measurements.
2. Incorrect/inaccurate accounts of
the actual lab study
3. Inadequate test systems
FAMOUS EXAMPLE
 One of the labs that went
under such an investigation
made headline news.
 The name of the Lab was
Industrial Bio Test. This was a
big lab that ran tests for big
companies such as Procter and
Gamble.
 It was discovered that mice
that they had used to test
cosmetics such as lotion and
deodorants had developed
cancer and died.
 Industrial Bio Test lab threw
the dead mice and covered
results deeming the products
good for human consumption.
 Those involved in production,
distribution and sales for the
lab eventually served jail time.
OBJECTIVES OF GLP

 GLP makes sure that the data submitted


are a true reflection of the results that are
obtained during the study.
 GLP also makes sure that data is
traceable.
 Promotes international acceptance of
tests.
MISSION OF GLP
 Test systems
 Archiving of records and materials.
 Apparatus, material and reagent facilities.
 Quality assurance programs.
 Performance of the study.
 Reporting of study results.
 Standard operating procedures (SOP)
 Personnel and test facility organization
Standard Operating Procedures
(SOP)
 Written procedures for a laboratories
program.
 They define how to carry out protocol-
specified activities.
 Most often written in a chronological
listing of action steps.
 They are written to explain how the
procedures are suppose to work
SOP
 Routine inspection, cleaning,
maintenance, testing and calibration.
 Actions to be taken in response to
equipment failure.
 Analytical methods
 Definition of raw data
 Keeping records, reporting, storage,
mixing, and retrieval of data
Statistical Procedures for Data
Evaluation
 Statistical procedures are not simply
chosen from a text book
 Practitioners in a particular field may
adopt certain standards which are deemed
acceptable within that field.
 Regulatory agencies often describe
acceptable statistical procedures.
Instrumentation Validation
 This is a process necessary for any
analytical laboratory.
 Data produced by “faulty” instruments
may give the appearance of valid data.
 The frequency for calibration, re-validation
and testing depends on the instrument
and extent of its use in the laboratory.
 Whenever an instrument’s performance is
outside the “control limits” reports must
be discontinued
Instrument Validation (cont)

 Equipment records should include:


 Name of the equipment and manufacturer
 Model or type for identification
 Serial number
 Date equipment was received in the
laboratory
 Copy of manufacturers operating
instruction (s)
Reagent/ Materials Certification

 This policy is to assure that reagents used


are specified in the standard operating
procedure.

 Purchasing and testing should be handled


by a quality assurance program.
Reagents and Solutions cont

 Requirements:
 Reagents and solutions shall be labeled
 Deteriorated or outdated reagents and
solutions shall not be used
 Include Date opened
 Stored under ambient temperature
 Expiration date
Analyst Certification

 Some acceptable proof of satisfactory


training and/or competence with specific
laboratory procedures must be established
for each analyst.
 Qualification can come from education,
experience or additional trainings, but it
should be documented
 Sufficient people
 Requirements of certification vary
Laboratory Certification
 Normally done by an external agency
 Evaluation is concerned with issues such as
 Adequate space
 Ventilation
 Storage
 Hygiene
Specimen/Sample Tracking
 Vary among laboratories
 Must maintain the unmistakable
connection between a set of analytical
data and the specimen and/or samples
from which they were obtained.
 Original source of specimen/sample (s)
must be recorded and unmistakably
connected with the set of analytical data.
Documentation and Maintenance of
Records
 Maintenance of all records provide
documentation which may be required in the
event of legal challenges due to repercussions of
decisions based on the original analytical results.
 General guidelines followed in regulated
laboratories is to maintain records for at least
five years
 Length of time over which laboratory records
should be maintained will vary with the situation
Good Documentation Practice
 Documentation should permit the
complete reconstruction of a study

 Record data directly, promptly and legibly in


indelible ink (never pencil)

 Initial and date all observations and any resulting


changes, but do not obscure original data
 Initial and date only work you’ve performed
 Do not document selectively or in advance of
performing the activity
Good Documentation Practice
 Do not use white-out correction fluid or tape
 Do not use ditto marks as raw data
 Copy all heat sensitive paper and stamp
“exact copy”
 Explain why any raw data not used was not
used
 Verify critical calculations using a second
person and document this
 Notebook pages requiring a second signature
shall be completed with that signature
Good Documentation Practice
 Properly head all pages, tables, columns;
identify units
 Describe Statistical & Calculation Procedures
used
 Sign, Date, and File automated printouts
(e.g., QC forms)
 Retain all Raw Data (original records) in the
Study File
 Do not document by exception. Use positive
documentation, even if only a check mark.
Good Documentation Practice
 Documentation must allow another person to
be able to accurately reconstruct what you
have done
 Keep all original observations including those
observations recorded directly into a
computer
 Sign and date all computer printouts
 Never back-date anything
 Follow SOPs and Protocol
Good Documentation Practice
 Document all deviations with accompanying
explanations
 Indicate in the record all applicable units and
equipment used
Important questions to be answered for any
analytical instrument
 What is the equipment being used for?

 Is the instrument within specification and is the


documentation to prove this available?

 If the instrument is not within specifications, how


much does it deviate by?

 If the instrument is not within specifications what


action has been taken to overcome the defect?

 Can the standards used to test and calibrate the


instrument be traced back to national standards?
What happens if a workplace
does not comply with Good
Laboratory Practice standards?
Disqualification of a Facility
 Before a workplace can experience the
consequences of noncompliance, an
explanation of disqualification is needed
 The FDA states the purpose of
disqualification as the exclusion of a
testing facility from completing laboratory
studies or starting any new studies due to
not following the standards of compliance
set by the Good Laboratory Practice
manual
Possible Violations

 Falsifying information for permit,


registration or any required records
 Falsifying information related to testing~
protocols, ingredients, observations, data
equipment, ect.
 Failure to prepare, retain, or submit
written records required by law
Grounds for Disqualification
 The testing facility failed to comply with
one or more regulations implemented by
the GLP manual
 The failure to comply led to adverse
outcomes in the data; in other words, it
affected the validity of the study
 Warnings or rejection of previous studies
have not been adequate to improve the
facility’s compliance
Consequences of Noncompliance
 The FDA states the following consequences of
noncompliance:
 The commissioner will send a written proposal of
disqualification to the testing facility
 A regulatory hearing on the disqualification will be
scheduled
 If the commissioner finds that after the hearing, the
facility has complied, then a written statement with
an explanation of termination of disqualification will
be sent to the facility
 Thus, if it can be shown that such disqualifications did
not affect the integrity and outcome of the study
itself, or did not occur at all, then the study may be
reinstated at the will of the commissioner
Upon Disqualification…
If the commissioner finds that the facility was
noncompliant on any of the grounds after the
hearing, then a final order of noncompliance will be
sent to the facility with explanations
 If a testing facility has been disqualified, any studies
done before of after the disqualification will need to be
determined as essential to a decision (acceptable or not)
 If the study is determined unacceptable, then the facility
itself may need to show that the study was not affected
by the noncompliance that led to the disqualification
 Once finally disqualified, the facility may not receive or
be considered for a research or marketing permit and
the study is rejected.
Upon Disqualification…
 The commissioner may notify the public and all
interested persons, including other federal agencies the
facility may have contacted
 The FDA may ask the other agencies to consider
whether to support the facility or not under the
disqualification
 Civil or criminal proceedings may occur at the discretion
of the commissioner
 Fines of up to $50,000 if one knowingly commits crime
and/or 1 year imprisonment~ for registration applicants and
producers
 Fines up to $5,000 all others~ civil penalty after failing to
improve after a minor violation warning was issued~ only
those involved in testing will be given civil penalties
 Those involved in the distribution or sales will be assessed
more heavy penalties, such as criminal penalties
Upon Disqualification…
 The FDA may turn it over to the federal,
state or local law enforcement
 The facility’s sponsor may terminate or
suspend the facility from doing any non-
clinical study for a permit
 The sponsor is required to notify the FDA
in writing within 15 working days that the
facility is to be suspended or terminated
and why
Reinstatement of a Disqualified
Facility
 The testing facility may be reinstated as
acceptable non-clinical study to be turned into
the FDA if the commissioner can be certain that
future studies will be conducted in compliance
with the Good Laboratory Practice standards and
that any current studies integrity have not been
severely harmed by the disqualification
 The disqualified facility will be required to put in
writing to the commissioner reasons why it
should be reinstated and any actions the facility
will take or have taken to assure any
disqualification problems will not happen again
Reinstatement of a Disqualified
Facility

 The commissioner will inspect the facility


and determine if it shall be reinstated
 If it is reinstated, the commissioner is
required to notify all persons that were
notified of the disqualification including
the facility itself
References

 http://www.sjsu.edu/faculty/chem55/55gl
pout.htm
 http://www.labcompliance.com/tutorial/gl
p/default.aspx?sm=d_a
 Wikipedia

You might also like