NDT RT NDS1

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 46

RADIOGRAPHY

TESTING
ELEMENTS OF RADIOGRAPHIC TESTING

• RADIATION SOURCE
• OBJECT
• RECORDING MEDIUM
• IMAGE QUALITY INDICATOR
• FILM PROCESSING FACILITY
• EVALUATION
• RADIATION MONITORING
• RADIOGRAPHER
ELECTROMAGNETIC SPECTRUM
PRINCIPLES
GEOMETRIC PRINCIPLES
GEOMETRIC PRINCIPLES
GEOMETRIC PRINCIPLES
GEOMETRIC PRINCIPLES
CONSTRUCTION OF X RAY MACHINE
FOCAL SPOT
ANODE
X RAY UNIT –ELECTRIC CIRCUIT
X RAY UNIT - CONTROLS
RADIOACTIVESOURCE CAMERA
GAMMA RAY CAMERA OPERATION
TECHOPS CAMERA
ISOTOPE CAMERA
DRIVING DEVICE
Techniques

Single Wall Single Image Double wall Single image

Source Radiation
Techniques

Double Wall Double Image Panoramic Exposure

Source Radiation
RADIOGRAPHIC FILM
CHARACTERISTIC CURVE
1) A “DYNAMIC MODE” WHEE INTERPRETATION IS
DONE WHILE “RADIATION IS ON”.
2)PRESENT A POSITIVE IMAGE.
3)IMMEDIATE FEED BACK TO WELEDER FOR
CORRECTIVE ACTION .
4)MORE PRODUCTIVITY WITH MINIMUM DEFECTS.
5)COMPUTER PROCESSING USING DIGITAL FORMAT
TO ENITANCE REAL TIME IMAGE.
6)SENSITIVITY ATTAINED EQUIAVALRNT TO FILM
RADIOGAPHY.
7)COMPUTER FACILITY FOR STORING RETRIVAL AND
ANALYSIS OF IMAGE.
8)OPERATION IS PERFORMED IN SAFETY ENCLOSURE.
FILM PROCESSING
FILM ARTIFACTS
HOLE TYPE PENETRAMETER
IMAGE QUALITY INDICATOR
2 % JOB THICKNESS IN FILM PROCESSING
INCHES/1000 Q UALITY

DESIGNATION IN THOU SENSITIVITY


CONTRAST
eg
DEFINITION
JOB THICKNESS = 1 INCH FILM GRAIN SIZE

= 1000 THOU
2% = 20 THOU
IQI FOR 1 INCH JOB THICKNESS :
ASTM 20
Sensitivity Level
Equivalent Quality Level T of Perceptible
Sensitivity % Penetrameter hole dia

0.7 1-1T 1 1T

1.0 1-2T 1 2T

1.4 2-1T 2 1T

2.0 2-2T 2 2T

2.8 2-4T 2 4T

4 4-2T 4 2T
RADIOGRAPHIC INDICATIONS

INTER-PASS SLAG INCLUSIONS

SLAG INCLUSION
SLAG INCLUSION
CLUSTER PORES

LACK OF PENETRATION
PORES

WORM HOLE