Jaipur: Vivekananda Institute of Technology

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 29

VIVEKANANDA INSTITUTE OF TECHNOLOGY

JAIPUR

THERMAL POWER PLANT


CONTENTS
1. Introduction
2. Power plant layout
3. Main and Auxiliary Equipments
4. Thermal power plants in Rajasthan
5. References
INTRODUCTION

A Thermal Power Plant converts the heat energy of coal into


electrical energy. Coal is burnt in a boiler which converts water
into steam. The expansion of steam in turbine produces
mechanical power which drives the alternator coupled to the
turbine.Thermal Power Plants contribute maximum to the
generation of Power for any country . Thermal Power Plants
constitute 75.43% of the total installed captive and non-captive
power generation in India . In thermal generating stations coal,
oil, natural gas etc. are employed as primary sources of energy.
GENERAL LAYOUT OF THERMAL POWER
STATION
Diagr am of a typical coal-fired thermal
p ow e r s ta t i o n
Diagr am of a typical coal-fired
t h e r m a l p o w e r s ta t i o n

1. Cooling tower 10. Steam Control valve 19. Superheater


2. Cooling water pump 11. High pressure steam turbine 20. Forced draught (draft) fan
3. transmission line (3-phase) 12. Deaerator 21. Reheater
4. Step-up transformer (3-phase) 13. Feed water heater 22. Combustion air intake
5. Electrical generator (3-phase) 14. Coal conveyor 23. Economiser
6. Low pressure steam turbine 15. Coal hopper 24. Air preheater
7. Condensate pump 16. Coal pulveriser 25. Precipitator
8. Surface condenser 17. Boiler steam drum 26. Induced draught (draft) fan
9. Intermediate pressure steam
18. Bottom ash hopper 27. Flue gas stack
turbine
MAIN AND AUXILIARY E Q U I P M E N T S
1. Coal handling plant
2. Pulverizing plant
3. Draft fans
4. Boiler
5. Ash handling plant
6. Turbine
7. Condenser
8. Cooling towers and ponds
9. Feed water heater
10. Economiser
11. Superheater and Reheater
12. Air preheater
COAL HANDLING PLANT

•The function of coal handling plant is automatic feeding of coal to the


boiler furnace.
• A thermal power plant burns enormous amounts of coal.
•A 200MW plant may require around 2000 tons of coal daily
PULVERISING PLANT

In modern thermal power plant , coal is


pulverised i.e. ground to dust like size and
carried to the furnace in a stream of hot air.
Pulverising is a means of exposing a large
surface area to the action of oxygen and
consequently helping combustion.
Pulverising mills are further classified as:
1. Contact mill
2. Ball mill
3. Impact mill
DRAFT SYSTEM
• The circulation of air is
caused by a difference in
pressure, known as Draft.
• Draft is a differential
pressure b/w atmosphere
and inside the boiler.
• It is necessary to cause the
flow of gases through boiler
setting
• It may be –
1. Natural draft
2. Mechanical draft
BOILER
BOILER

• A boiler or steam generator is a closed vessel in which water


under pressure, is converted into steam.
• It is one of the major components of a thermal power plant
• Always designed to absorb maximum amount of heat released in
the process of combustion
Boilers are of two types-
1. Fire tube boiler
2. Water tube boiler
SUPERHEATER AND REHEATER

Most of the modern boilers are having super heater and reheater arrangement.

Superheater :
Superheater is a component of a steam-generating unit in which steam, after it
has left the boiler drum, is heated above its saturation temperature. The amount
of superheat added to the steam is influenced by the location, arrangement, and
amount of super heater surface installed, as well as the rating of the boiler. The
super heater may consist of one or more stages of tube banks arranged to
effectively transfer heat from the products of combustion. Super heaters are
classified as convection , radiant or combination of these.
Reheater : Some of the heat of superheated steam is used to rotate the
turbine where it loses some of its energy. Reheater is also steam boiler
component in which heat is added to this intermediate-pressure steam,
which has given up some of its energy in expansion through the high-
pressure turbine. The steam after reheating is used to rotate the second
steam turbine where the heat is converted to mechanical energy. This
mechanical energy is used to run the alternator, which is coupled to turbine
, there by generating electrical energy.
TURBINE
TURBINE – FULL VIEW
STEAM TURBINE

A steam turbine converts heat energy of steam into mechanical


energy and drives the generator. It uses the principle that steam
when issuing from a small opening attains a high velocity. This
velocity attained during expansion depends on the initial and final
heat content of the steam. This difference b/w initial and final heat
content repesents the heat energy converted into kinetic energy.
These are of two types :-
Impulse turbine
Reaction turbine
ASH HANDLING PLANT
The percentage of ash in coal varies from 5% in good quality
coal to about 40% in poor quality coal
Power plants generally use poor quality of coal , thus amount
of ash produced by it is pretty large
A modern 2000MW plant produces about 5000 tons of ash
daily
The stations use some conveyor arrangement to carry ash to
dump sites directly or for carrying and loading it to trucks and
wagons which transport it to the site of disposal
CONDENSER
Steam after rotating steam turbine comes to condenser. Condenser
refers here to the shell and tube heat exchanger (or surface
condenser) installed at the outlet of every steam turbine in Thermal
power stations of utility companies generally.
These condensers are heat exchangers which convert steam from its
gaseous to its liquid state, also known as phase transition.
In so doing, the latent heat of steam is given out inside the
condenser. Where water is in short supply an air cooled condenser is
often used.
An air cooled condenser is however significantly more expensive and
cannot achieve as low a steam turbine backpressure (and therefore
less efficient) as a surface condenser.
The purpose is to condense the outlet (or exhaust) steam from steam
turbine to obtain maximum efficiency and also to get the condensed
steam in the form of pure water, otherwise known as condensate, back
to steam generator or (boiler) as boiler feed water.
COOLING TOWERS AND PONDS

o A condenser needs huge quantity of water to condense the steam .


o Typically a 2000MW plant needs about 1500MGallon of water.
oMost plants use a closed cooling system where warm water coming from
condenser is cooled and reused
oSmall plants use spray ponds and medium and large plants use cooling towers.
oCooling tower is a steel or concrete hyperbolic structure having a reservoir at the
base for storage of cooled water
oHeight of the cooling tower may be 150 m or so and diameter at the base is 150 m
FEED WATER HEATER

Advantages of heating water before feeding back to the boiler:-


a) Feed water heating improves overall plant efficiency.
b) The dissolved oxygen and carbon dioxide which would otherwise
cause boiler corrosion are removed in feed water heater
c) Thermal stresses due to cold water entering the boiler drum are
avoided.
d) Quantity of steam produced by the boiler is increased.
e) Some other impurities carried by the steam and condensate, due
to corrosion of boiler and condenser are precipitated outside the
boiler.
ECONOMISER
Flue gases coming out of the boiler carry lot of heat. An
economiser extracts a part of this heat from flue gases
and uses it for heating feed water. This use of
economiser results in saving coal consumption and
higher boiler efficiency
ECONOMIZER
AIR PREHEATER

After flue gases leave economiser, some further heat


can be extracted from them and used to heat incoming
heat. Cooling of flue gases by 20 degree centigrade
increases the plant efficiency by 1%.
Air preheaters may be of three types
Plate type
Tubular type
Regenerative type
THERMAL POWER PLANTS IN
RAJASTHAN
1. Chhabra thermal powerplant- 500MW
2. Kota super thermal powerplant- 1240MW
3. Giral lignite powerplant- 235MW
4. Suratgarh super thermal powerplant -1500MW
REFERENCES

Generation of electrical power- B.R.GUPTA


www.google.com
www.slideshare.com

You might also like