0% found this document useful (0 votes)
480 views24 pages

PipeSim ESP

This document outlines the steps to model an ESP selection and design in a reservoir simulation software: 1. Build a simple vertical well completion model with one branch, tubing, and outlet node. Select black oil properties and define the fluid model. 2. Add tubing details like material, diameter, and perforation settings. Select a multiphase flow correlation. 3. Run a nodal analysis with outlet pressure constraints and view results. 4. Enter pump design parameters like flow rate, pressure, and depth settings to select a Reda pump. View pump performance curves. 5. Install the pump in the model and run nodal analysis again to view results with the ESP.

Uploaded by

Gery Siregar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
480 views24 pages

PipeSim ESP

This document outlines the steps to model an ESP selection and design in a reservoir simulation software: 1. Build a simple vertical well completion model with one branch, tubing, and outlet node. Select black oil properties and define the fluid model. 2. Add tubing details like material, diameter, and perforation settings. Select a multiphase flow correlation. 3. Run a nodal analysis with outlet pressure constraints and view results. 4. Enter pump design parameters like flow rate, pressure, and depth settings to select a Reda pump. View pump performance curves. 5. Install the pump in the model and run nodal analysis again to view results with the ESP.

Uploaded by

Gery Siregar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 24

ESP Selection Design

Select New Single Branch Model


Build a Simple complation using t
he completion icon, tubing icon a
nd with an outlet node. Select the
Vertical Completion button and pl
ace it the single branch window.
Double click VertWell_1
 Enter 3625 psia in the Static P
ressure text box
 Enter 288 F in the Temperatur
e text box
 Select Well PI for Model Type
in the Completion Model field
 Select Liquid PI and enter 12.
4 stb/d/psi in the text box
 Click Use nonlinear correctio
n below bubble point
 Click OK
Define the Black Oil Fluid
Model by Setup > Black
Oil and click
 Select the Black Oil Properties t
ab
 In the Fluid Name field, enter ES
P
 In the Stock Tank Properties fiel
d, enter the following parameter
s:
 WC : 90%
 GOR : 449 scf/STB
 Gas SG : 0.984
 Water SG : 1.026
 API : 30
 In the Calibrating Data at Bubbl
e Point field, enter the following
parameters :
 Pressure : 2216 psia
 Temperature : 288 F
 Sat. Gas : 0.54 cP
 In the Solution Gas Correlation f
ield, select Lasater from the dro
p down menu
 Click OK
Double click Tubing_1
 In the Tubing_Tubing_1 window
, in the Preferred Tubing Model f
ield, select Simple Model from t
he drop down menu
 In the Ambient Temperature text
box, enter 68 F.
 In the Tubing section (#1 requir
ed, others optional) field, in the
Tubing #1 row and the MD colu
mn text, enter 2863
 In the Tubing #1 row and the ID
column text box, enter 3.958
 In the Tubing #2 row and the MD
column text box, enter 2863
 In the Tubing #2 row and the ID
column text box, enter 8.681
 In the Perforations field, MD text
box, enter 9393 ft from the drop
down menu and enter 288 F in t
he Reservoir Temperature text b
ox.
 Click OK
Select Setup > Flow Corr
elation and Click
In the Flow Correlation wi
ndow, in the Vertical Flow
(Multhiphase) field, select
Hagedorn & Brown for Co
rreclation and Click OK
Select Operation > Nodal
Analysis and Click
 In the Nodal Analysis window, i
n the Outlet Pressure text box, e
nter 250 psia
 Click Run Model
Result Nodal Analysis

Nodal After ESP


From Result Analysis We Can Select Pump Desig
n
Select Artificial Lift > ESP Design
 Enter the Pump Design Data par
ameters :
 Design Production Rate : 160
0 sm3/d
 Design Outlet Pressure : 8 ba
rg
 Pump setting depth : 2500 m
 ID : 8.681
 Design Frequency : 60 Hz
 Click Select Pump button
 Select Manufacturer to Reda
 Highlight and select the Reda H
N 13000 pump
 Click OK
Click the Calculate

Calculation Result
of ESP Design
It show by Pump P
erformance Plot an
d Pump Curv
Pump Performance Plot

Pump Curve
Install Pump
MD Pump Setting Depth, E
SP Data Automatically fill

Select Properties
To show result of ESP Design we must ru
n Nodal Analysis again
Nodal Before

You might also like