Lecture 18 Static Error Constants and System Type

The document summarizes key topics from Chapter 7 of the textbook "Control Systems Engineering" relating to steady-state error analysis of linear control systems. It defines static error constants like position, velocity, and acceleration constants that characterize steady-state error performance. It also discusses how steady-state error is affected by system type and disturbances. Examples are provided to illustrate how to determine static error constants, interpret specifications, and calculate steady-state error due to disturbances.

Uploaded by

Hamza Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
437 views21 pages

Lecture 18 Static Error Constants and System Type

The document summarizes key topics from Chapter 7 of the textbook "Control Systems Engineering" relating to steady-state error analysis of linear control systems. It defines static error constants like position, velocity, and acceleration constants that characterize steady-state error performance. It also discusses how steady-state error is affected by system type and disturbances. Examples are provided to illustrate how to determine static error constants, interpret specifications, and calculate steady-state error due to disturbances.

Uploaded by

Hamza Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 21

EE-379

LINEAR CONTROL SYSTEMS


Lecture No 18
“CONTROL SYSTEMS ENGINEERING”
Text Book: Chapter 7 (nn 6th Ed)
7.3 Static Error Constants and System Type, Page 349
7.4 Steady-State Error Specifications, Page 353
7.5 Steady-State Error for Disturbances, Page 356

Instructor: Dr. Farid Gul


Class: BEE 4A/B
Electrical Engineering Department
1
7.3 Static Error Constants and
System Type

2
Performance specifications for the
transient response
• damping ratio,
• natural frequency,
• settling time,
• percent overshoot,
• Peak time
• Rise time
Parameters that can be used as steady-state error
performance specifications, are called

static error constants


3
• The three terms in the denominator that
are taken to the limit determine the steady-
Static Error Constants state error.
• These limits are the static error constants.
For a step input, u(t),
Position Constant, Kp
1
e()  estep () 
1  lim G( s) K p  lim G ( s)
s 0 s 0

For a ramp input, tu(t), Velocity Constant, Kv


1
e()  estep () 
lim sG ( s) K v  lim sG ( s )
s 0 s 0

For a parabolic input, ½ t2u(t). Acceleration Constant, Ka

1
e()  estep () 
lim s 2G(s) Ka  lim s 2G(s)
s 0 s 0

4
Example 7.4 Steady-State Error via Static Error Constants

PROBLEM:
For each system in
the Figure, evaluate
the static error
constants and find the
expected error for the
standard step, ramp,
and parabolic inputs.

5
6
7
8
System Type

Since steady-state errors are dependent upon the number of integrations in


the forward path, a name is given to this system attribute

system type is defined to be the value ofnin the denominator.


Thus:
a system with n = 0 is a Type 0 system
n=1 is a Type 1 system
n=2 is a Type 2 system
9
Table 7.2
Relationships between input, system type, static error
constants, and steady-state errors

10
7.4 Steady-State Error
Specifications

11
Just as
damping ratio, ζ
settling time, Ts
peak time, Tp
percent overshoot, % OS
are used as specifications for a control system's
transient response

Position constant, Kp
Velocity constant, Kv
Acceleration constant, Ka

are used as specifications for a control system's


steady-state errors

12
Wealth of information contained within the
specification of a static error constant
For example, if a control system has the specification Kv = 1000,
we can draw several conclusions:
1. The system is stable.
2. The system is of Type 1, since only Type 1 systems have Kv's that are finite
constants.
Recall that Kv = 0 for Type 0 systems
Kv =  for Type 2 systems
3. A ramp input is the test signal.
Since Kv is specified as a finite constant, and the steady-state error for a
ramp input is inversely proportional to Kv, we know the test input is a ramp.
4. The steady-state error between the input ramp and the output ramp is 1/Kv per unit
of input.

13
Example 7.5 Interpreting the Steady-State Error Specification

PROBLEM:
What information is contained in the specification Kp = 1000?

SOLUTION:
• The system is stable.
• The system is Type 0, since only a Type 0 system has a
finite Kp. Type 1 and Type 2 systems have Kp = 
• The input test signal is a step, since Kp is specified.
• The error per unit step is

1 1 1
e( )   
1  K p 1  1000 1001

14
Example 7.6 Gain Design to Meet a Steady-State Error Specification

PROBLEM: Given the control


system in the Figure, find the
value of K so that there is 10%
error in the steady state.

SOLUTION: Since the system is Type 1, the error stated in


the problem must apply to a ramp input; only a ramp yields
a finite error in a Type 1 system. Thus,

15
7.5 Steady-State Error for
Disturbances

16
Figure 7.11
Feedback control system
showing disturbance

R( s)  E ( s)  E ( s)G1 ( s)G2 ( s)  D( s)G2 ( s)

R( s)  D( s)G2 ( s)  1  G1 ( s)G2 ( s)  E ( s)

1 G2 ( s )
E (s)  R( s)  D( s)
1  G1 ( s )G2 ( s ) 1  G1 ( s )G2 ( s )

transfer function
transfer function
relating E(s) to D(s)
relating E(s) to R(s)

17
1 G2 ( s )
E (s)  R( s)  D( s)
1  G1 ( s )G2 ( s ) 1  G1 ( s )G2 ( s )
Applying the final value theorem
s sG2 ( s )
e()  lim sE ( s )  lim R( s)  lim D( s )
s 0 s  0 1  G ( s )G ( s ) s  0 1  G ( s )G ( s )
1 2 1 2

s Assume a step disturbance,


eR ()  lim R( s)
s  0 1  G ( s )G ( s ) D(s) = 1/s.
1 2

G2 ( s)
eD ()   lim
sG2 ( s) s  0 1  G ( s )G ( s )
eD ()   lim D( s) 1 2
s  0 1  G ( s )G ( s )
1 2

1
eD ()  
Let us explore the conditions on eD () 1
that must exist to reduce the error due to  lim G1 ( s)
lim G2 ( s) s 0
the disturbance s 0

18
1
eD ()  
1
 lim G1 ( s)
lim G2 ( s) s 0
s 0

The ss error produced by a step


disturbance can be reduced by:
a. increasing the dc gain of
G1(s)

or
a. decreasing the dc gain of
G2(s)

System rearranged to show disturbance as


input and error as output, with R(s) = 0

19
Example 7.7 Steady-State Error Due to Step Disturbance

PROBLEM: Find the steady-state error component due to a step


disturbance for the system shown in the Figure.

SOLUTION: The system is stable

1 1 1
eD ()    
1
 lim G1 ( s) 0  1000 1000
lim G2 ( s) s 0
s 0

the steady-state error produced by the step disturbance


is inversely proportional to the dc gain of G1 (s)