NR 8000

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 17

NR8000 MW Operation Guide for

Digicel MAKO Project in TnT


Laptop connect to IDU’s LMT port using LAN cable

E-mail: [email protected]
Step 1:Setting IP address as 192.168.1.15 in you laptop

Step 2:Open the IE browser (Chrome is recommended), input


the IP: 192.168.1.1, and press Enter, as shown in the figure
below.

Step 3:
User Name : admin Password : admin or User123#
Click LOGIN
Introduce : IDU System Detail Menu
Introduce : NR8250 IDU
System Detail Menu

Introduce : NR8120D IDU


System Detail Menu
Step 4 (Only for NR8250 IDU): Setting Shelf (Path: Basic Config -> Shelf)
Step 5: Click : Basic Config -> System, the page of NE information will display
Step 6: Setting Site ID, NE Name, Device IP Address follow Design information
Step 7: Click : Basic Config -> RadioChannel, the page of Channel will display
Step 8: Setting Tx Frequency, Rx Frequency, Tx Power, Channel Name, Bandwidth, Modulation follow
Design information

Antenna alignment can start after this step setting on both sites of
one link ; RSL must achieve Design Value.
Step 9 (Only for 2+0 XPIC Link): Setting PLA (Path: Basic Config -> RadioChannel -> PLA)

Attention: All the interfaces have been defined in MPLS Script, include Eth Ports, Gbe Ports, RMUF
interfaces, PLA interfaces . So Please confirm which PLA No. used for which Link from LLD before setting.
Step 10 (Only for 2+0 XPIC Link): Setting XPIC (Path: Basic Config -> RadioChannel -> XPIC)

2+0 XPIC Setting Finished (only step 8 & step 9)!!


Step 11: Click : Basic Config -> Port, the page of Port will display
Step 12: Enable the ports that are requested by design
Introduce : Two scripts will prepare for every IDU, <Site ID>_IDU1.cli script for MPLS setting and <Site ID>_IDU1_MOS.cli
scipt for QoS setting.
Step 13:MPLS Setting : Open cmd.exe, enter below red character and Paste MPLS Script

Remark: You could copy all script and


paste them in one time!

Paste MPLS Script on here


Step 14:QoS Setting : Open cmd.exe, enter below red character and Paste QoS Script

Remark: You could copy all


script and paste them in
one time!

Here is , not .