0% found this document useful (0 votes)
149 views

Dynamic SDCCH Algorithm - Huawei

The document describes an algorithm for dynamically adjusting the number of SDCCH channels in a cell based on idle channel thresholds. It details conditions for converting TCH channels to SDCCH and vice versa to optimize resource usage based on traffic levels.

Uploaded by

Muhammad Zain
Copyright
© © All Rights Reserved
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
149 views

Dynamic SDCCH Algorithm - Huawei

The document describes an algorithm for dynamically adjusting the number of SDCCH channels in a cell based on idle channel thresholds. It details conditions for converting TCH channels to SDCCH and vice versa to optimize resource usage based on traffic levels.

Uploaded by

Muhammad Zain
Copyright
© © All Rights Reserved
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 10

© VimpelCom Ltd 2012

Dynamic SDCCH Algorithm


B/m is TCH ~ Dynamic SDCCH algorithm:

 If the number of idle SDCCHs in the cell is smaller than or equal to the value of Idle SDCCH Threshold N1
,the BSC tries to find a TCHF that can be converted to the SDCCH.

if number of idle SDCCH TSs <= Idle SDCCH Threshold N1


© VimpelCom Ltd 2012

 Now BSC will check following three conditions for initiating the conversion from TCHFs to SDCCHs:

 The cell allows the SDCCH dynamic adjustment


 (Number of idle TCHFs + number of idle TCHHs/2) ≥ 4 or the number of TRXs in the cell, and the cell must have
at least one idle TCHF
 The sum of the number of SDCCHs in the cell plus eight is smaller than the maximum number of SDCCHs
allowed in the cell

When all a/m conditions are true then

Convert TCHF >>>>>>>>> Dynamic SDCCH


TCH Recovery Algorithm
 Dynamic SDCCH to TCH conversion back algorithm is given below:

 Each cell is configured with a counter S. Each time the TCH is converted to the SDCCH, the counter is set to ResTime.
The value of the counter is adjusted every three seconds.

Where ResTime = TCH Min Recovery Time [Minimum time for the recovery of a TCH from SDCCH]
© VimpelCom Ltd 2012

If
Number of Idle SDCCHs > 8 + Idle SDCCH Threshold N1
[S decreased by 3]

If
Number of Idle SDCCHs < 8 + Idle SDCCH Threshold N1
[S increased by 12 but not above than TCH recovery Time]

If
Number of Idle SDCCHs = 8 + Idle SDCCH Threshold N1
[S is unchanged]

If the value of the counter S is equal to or lower than 0 after adjustment, the SDCCH is converted to the TCH.
© VimpelCom Ltd 2012

Related Parameters
Dynamic Allocation Enabled
© VimpelCom Ltd 2012
Cell SDCCH Channel Maximum
© VimpelCom Ltd 2012
Idle SDCCH Threshold N1
© VimpelCom Ltd 2012
TCH Minimum Recovery Time(s)
© VimpelCom Ltd 2012
EID Sample WO [For Reference]
 Dynamic SDCCH sample WO for EID is pasted below for reference:
© VimpelCom Ltd 2012

Idle SDCCH Threshold N1


BSC Cell Index Cell Name CI
Current Proposed
ISB644H__I-10_Building_ISB_1 44 ISB0232__H_G61 232 2 8
ISB644H__I-10_Building_ISB_1 7 ISB10005__S_Parliament_Lodges 10005 2 8
ISB650H__I-10_Building_ISB_4 237 ISB10013__P_F103 10013 2 8
© VimpelCom Ltd 2012

Thank You

You might also like