Calibration of MCII
Calibration of MCII
Divisor:
55.43 P/Gal X 42 Gal/Bbl = 2328.06 P/Bbl
Rate Multiplier:
Since This Is a ‘Per Day’ Rate, We Will Use ONC.
Step #3
Set The Jumpers
• To Open The MC-II, Loosen
the Eight Screws Around
the Back of the Housing.
• These Are Captive Screws
and Will Not Come All the
Way Out.
• When They Are All Loose,
the Face Plate Will Fall
Open.
• Plastic Straps Attach the
Face Plate to the Housing So
It Does Not Fall off.
• The Jumpers Are Located
on the Bottom of the
Circuit Card.
Step #3
Set The Jumpers
ONC Jumper
ONC Enable
RST Calibrate
Jumper
CAL Enable
display should be
blank.
FLOW MEASUREMENT SYSTEMS
Step #4
Enter The Divisor
MODEL MC-II
• Enter The Divisor FLOW ANALYZER
From Right To Left 0
TOTAL (BBLS)
2 3 28
Left To Right RATE (BPD)
CALIBRATION
Divisor = 2328
Mul. Fac. = ONC
Step #4
Enter The Divisor
MODEL MC-II
• Enter The Divisor FLOW ANALYZER
From Right To Left 07
4
0
3
2
8
5
1
6
• Press The Increment TOTAL (BBLS)
Button Repeatedly
Until the Display
Shows the Proper
RATE (BPD)
Number in That Place.
CALIBRATION
• Press The Enter DEC. INCRE- ENTER VIEW
ACCESS RESET
Button Once To Set POINT MENT
STEP
DIV.
Divisor = 2328
Mul. Fac. = ONC
Step #4
Enter The Divisor
MODEL MC-II
• Enter The Divisor FLOW ANALYZER
From Right To Left 00
2
18
• Press The Increment TOTAL (BBLS)
Button Repeatedly
Until the Display
Shows the Proper
RATE (BPD)
Number in That Place.
CALIBRATION
• Press The Enter DEC. INCRE- ENTER VIEW
ACCESS RESET
Button Once To Set POINT MENT
STEP
DIV.
Divisor = 2328
Mul. Fac. = ONC
Step #4
Enter The Divisor
MODEL MC-II
• Enter The Divisor FLOW ANALYZER
From Right To Left 02
0
3
128
• Press The Increment TOTAL (BBLS)
Button Repeatedly
Until the Display
Shows the Proper
RATE (BPD)
Number in That Place.
CALIBRATION
• Press The Enter DEC. INCRE- ENTER VIEW
ACCESS RESET
Button Once To Set POINT MENT
STEP
DIV.
Divisor = 2328
Mul. Fac. = ONC
Step #4
Enter The Divisor
MODEL MC-II
• Enter The Divisor FLOW ANALYZER
From Right To Left 02
0
13 28
• Press The Increment TOTAL (BBLS)
Button Repeatedly
Until the Display
Shows the Proper
RATE (BPD)
Number in That Place.
CALIBRATION
• Press The Enter DEC. INCRE- ENTER VIEW
ACCESS RESET
Button Once To Set POINT MENT
STEP
DIV.
Divisor = 2328
Mul. Fac. = ONC
Step #4
Enter The Divisor
• Press The Enter Button MODEL MC-II
Again. FLOW ANALYZER
• Notice the ‘L’. This Is 0232
L80
Asking If the Divisor
TOTAL (BBLS)
Represents Full Barrels or
Represents 1/10, 1/100, or 0.0
1/1000 of a Barrel.
RATE (BPD)
• Since Our Divisor Is CALIBRATION
Pulses Per Full Barrel, We
DEC. INCRE- ENTER VIEW
Pass This up by Pressing ACCESS
POINT MENT
STEP
DIV.
RESET
Enter Again
Divisor = 2328
Mul. Fac. = ONC
Step #5
Verify The Divisor
MODEL MC-II
• Press And Hold The
FLOW ANALYZER
View Divisor Button
• After a Short Delay, the 2 3 2 80
Numbers Will Change. TOTAL (BBLS)
Divisor = 2328
Mul. Fac. = ONC
Step #5
Verify The Divisor
MODEL MC-II
• Press And Hold The
FLOW ANALYZER
View Divisor Button
• The Bottom Display 2328
Shows the Rate Multiplier TOTAL (BBLS)
Divisor = 2328
Mul. Fac. = ONC
Step #5
Verify The Divisor
MODEL MC-II
• Release The View
FLOW ANALYZER
Divisor Button
• The Display Returns to Its 2 3 2 80
Previous Reading. TOTAL (BBLS)