Scaffolding
Scaffolding
Scaffolding
Scaffold Safety
(General Instruction 8.001)
Purpose:
To establish the minimum safety-related technical
requirements for temporary elevated work areas,
ladders, and scaffolds.
Scope:
Covers the design, erection, use, alteration, and
dismantling of temporary elevated work areas, ladders,
and supported or underhung scaffolds with fixed
platform heights. The types of scaffolds covered are
those commonly use within TECNIMONT, including tube
and coupler, fabricated tubular frame, system, bracket,
underhung, and manually propelled mobile scaffolds.
2
STANDARDS
3
TOPICS SLIDE NUMBER i
I. SCAFFOLD TERMINOLY 5-7
II. ELEVATED WORK AREAS – GENERAL
REQUIREMENTS 8-11
III. SCAFFOLDING COMPONENTS 12-14
IV. REQUIREMENTS COMMON TO ALL
SCAFFOLDS 15-24
V. REQUIREMENTS COMMON TO SYSTEM AND
TUBE & COUPLER SCAFFOLDS 25-32
VI. SYSTEM SCAFFOLDS 33-36
VII. TUBE & COUPLER SCAFFOLDS 37-60
VIII. MOBILE & TOWER SCAFFOLDS 61-65
IX. FABRICATED TUBULAR FRAME SCAFFOLDS 66
X. BRACKET SCAFFOLDS 67-69
XI. UNDERHUNG SCAFFOLDS 70-75
XII. SCAFFOLD TAGGING 76-79
XIII. SCAFFOLD SAFETY SEMINAR – HIGHLIGHTS
S.A. LPD – (Sept. 2002) 80-86
4
I. SCAFFOLD TERMINOLOGY
TOP RAIL
MID RAIL
DROP BAR
FALSE UPRIGHT
0.95m – 1.15 m
(38”-45”)
36” in.
RUNNER (LEDGER)
TRANSVERSE BRACING
BASE LIFT
(KICKER LIFT)
6"
BASE PLATE
SILL (SOLE BOARD)
5
I. SCAFFOLD TERMINOLOGY
RUNNERS
(LEDGERS)
RUNNERS &
BEARERS
INSTALLED
BEARERS INSIDE POSTS
(TRANSOMS) TYP.
POST
(STANDARD)
BASE PLATES
SILLS (SOLE
BOARDS) BASE LIFT
(KICKER LIFT)
6
I. SCAFFOLD TERMINOLOGY
BEARERS RUNNERS
(TRANSOMS) (LEDGERS)
BAY LENGTH
BAY SCAFFOLD
WIDTH
LIFT
6” HEIGHT
POST
(STANDARD)
BASE LIFT
(Foot Tie or Kicker Lift)
7
II. ELEVATED WORK AREAS - GENERAL REQUIREMENTS
FALL PROTECTION
Each person who could fall more than 1.8 m. (6 ft.) shall be protected
from falling by means of guardrail systems or personal fall arrest
systems.
GUARDRAIL SYSTEMS
Guardrail system shall be able to withstand a force of at least 90kg.
(200 lbs.) It consists:
1. Toprails - top edge height of toprails self closing
shall not be less than 0.95 m. (38 “) drop bar
false
and not more than 1.15 m. (45”) upright
above the walking/working surface of a toprails (puncheon)
platform. midrails
2. Midrails – installed approximately
halfway between the walking/working
surface and toprail.
3. Toeboards – shall have no more than
6 mm. (1/4”) gap above the working
surface and should withstand a force of
at least 23 kg (50 lbs).
4. Uprights – shall not be spaced more
toeboards
than 2.7 m. (9 ft.) apart.
8
II. ELEVATED WORK AREAS - GENERAL REQUIREMENTS
TEMPORARY STAIRWAYS
PARTS OF STAIRWAY REQUIREMENTS
LANDING • At least 560 mm. (22”) wide & 760 mm. (30”) long.
• Shall have landing not more than every 3.7 m. (12’) of vertical
distance.
10
II. ELEVATED WORK AREAS - GENERAL REQUIREMENTS
TEMPORARY RAMPS
Shall not be inclined more than a ratio of 1 : 3 or 20º above the horizontal although a
slope not over 15º is preferred.
If steeper than ratio 1 : 4 the ramp shall have cleats no more than 350 mm (14”) apart.
HIGH WINDS
Personnel shall not be on any scaffold or other temporary elevated work area during
storms or high winds – sustained winds more than 65 kph (40 mph).
LADDERS
A slope of 4:1, side rails rigidly attached to supporting structure (top, middle, bottom).
Rungs uniformly spaced between 250 mm (10”) and 360 mm (14”) although 300 mm
(12 inches) is preferred.
Shall have a minimum clear distance of 760 mm (30”) to the nearest protruding object on
the climbing side. This distance maybe reduced to 610 mm (24 inches) if deflector plates
are provided.
Distance on the climbing side to the nearest object on the back side of the ladder shall be
no less than 250 mm (10 inches). When unavoidable a minimum vertical toe clearance
of 100 mm. (4”) shall apply.
11
III. SCAFFOLDING COMPONENTS
GENERAL
Scaffold components manufactured by different manufacturers should not be
intermixed unless the components are compatible and the scaffold’s structural integrity
is maintained.
All defective scaffold component s shall be marked with bright fluorescent orange paint
and immediately removed from TECNIMONT property or project site.
30 KN
Girder coupler
(Drop forged)
Shear - 6,740 lbs.
(per pair)
13
III. SCAFFOLDING COMPONENTS
PLATFORM UNITS
Wood Plank Dimensions Certified / Approved Requirements
by
Solid Sawn 2x10 inch (nom) • West Coast Lumber • Shall be certified and bear a
Inspection Bureau grade stamp
Wood 2x9 inch (rough) (WCLB) • Free from defects
• Southern Pine •Splits 25mm (1”) max. w/o banding
38x25mm or Inspection Bureau 300mm (1’)max. w/ banding
50x225 mm (SPIB) •Twist 13mm (1/2”) max. end to end
(basic) • American Lumber • Shall not be painted treated or
Standards coated (except at the ends)
Committee
• Shall be properly stacked. If
Laminated 38mm (1-1/2”) • Shall have the word height stack exceeds 20
by 225mm (9”) “PROOF TESTED planks, succeeding layers
Veneer SCAFFOLD PLANK”
wide or larger should be tied or bond.
Lumber and “OSHA” or
TECNIMONT • Shall not stood on end
accepted equivalent, unattended
continuously
embossed on both
edges.
The maximum deflection for platform units shall not exceed 1/60th of the
span length when supporting any of the unfactored concentrated or
uniformly distributed concentrated loads.
15
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
FOUNDATIONS
Foundations shall be sound, rigid, and capable of carrying the scaffold
self-weight plus the maximum intended load without settling or
displacement.
Scaffolds shall not be hung from or supported by guardrails or handrails.
Components Requirements
• At least 225 mm. (9”) wide by 38
mm. (1-1/2”) thick
Timber Sills • Shall extend under at least two posts
(sole boards) (standard), if not applicable sills under
individual posts shall be at least 765
mm. (30”) long
• At least 150 x 150mm. & 6mm. thick
Steel Base (6 x 6 inches & 1/4 inch thick)
Plates • For special scaffolds base shall be
designed
• Shall not be adjusted to more than two-
Screw Jacks thirds (2/3) of the total length of the
threaded section
16
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
STABILITY
Scaffold posts and frames shall be vertically plumb and vertically braced
in both directions.
Supported scaffolds with a height to the uppermost planked level that is
over four times the minimum base dimension (over a 4:1 height-to-
width ratio) shall be restrained from tipping by ties, guys, outrigger
frames, or equivalent means.
Ties and guys shall be installed as follows:
BOX TIE RIGHT-ANGLE (DOUBLE)
REVEAL TUBE TIE TUBE COUPLERS (TYP.)
REVEAL PIN
REVEAL TUBE
WALL OR WALL OR
SOLID SOLID
STRUCTURE STRUCTURE
TIE TUBES TO
SCAFFOLD
REVEAL TIES
(MAXIMUM 50% OF TOTAL TIES)
BOX TIES PLAN VIEW OF
SCAFFOLD TIES REVEAL TIES
17
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
STABILITY
Ties and guys shall be installed as follows:
RIGHT-ANGLE (DOUBLE) RIGHT-ANGLE (DOUBLE)
COUPLERS (TYP.) COUPLERS (TYP.)
WALL OR WALL OR
SOLID SOLID
STRUCTURE
TIMBER PACKING
STRUCTURE
TIE TUBES TO
TIE TUBES TO SCAFFOLD
SCAFFOLD
PLAN VIEW OF COLUMN BOX TIE PLAN VIEW OF TWO-WAY TIES
Ties or guys shall be spaced vertically every 8 m. (26’)(4 lifts) or
less.
Ties or guys shall be installed on both ends of the scaffold and at
horizontal intervals not to exceed 9 m. (30’) measured from one end
toward the other.
18
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
STABILITY
ONLY ONE ADDITIONAL
LIFT ALLOWED ABOVE
RAKER TIE-IN POINT
LONGITUDINAL
STRUT TUBE
BASE PLATE
SOLE BOARD
SHORT BUTT
TUBE
BASE PLATE
DETAIL
GROUND LEVEL
1.25 m
45 APPROX.
APPROX.
ALTERNATIVE ON
HORIZONTAL TIE
TUBES (REQUIRED)
HARD GROUND
CROSS TUBE
RAKER
19
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
If the front edge of a working platform is less than 360 mm. (14”)
from the face of the wall or structure, guardrails do not need to be
erected from that edge.
For medium-duty and more heavily loaded scaffolds, at least one board
bearer (intermediate transom) shall be used in every bay at each
platform level.
Planks should be secured on both ends by using fiber rope/wire lashing,
clamped toe boards or other equivalent means. Planks & toeboards
should not be nailed.
The slope of platform units shall not exceed 1 vertical to 4 horizontal.
Scaffold platforms, landings, and walkways should be at least
675 mm. (27”) (3planks) wide, including during erection,
dismantling and alteration.
Scaffold materials shall not be thrown or dropped from heights.
20
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
o Gaps less than 600 mm. (2’) in width shall be covered at least 20
mm. (1”) thick, exterior grade plywood. Plywood covering shall be
overlapped with at least the width of the gap, 12” min., on both
sides of the opening and held with cleats.
o Gaps larger than 600 mm. (2’) in width shall be covered with
properly secured cross planks.
Safe landings shall be provided at the top of all ladders and at least every
9m. (30’) of ladder height.
If an internal ladder is used, opening shall be at least 675mm. (27”) (3
planks) wide & not less than 900mm (36”) deep.
If an external ladder is used, step-through opening width on guardrails
shall not be less than 675 mm. (27”) or more than 760 mm. (30”).
The slope of scaffold platform units shall not exceed 1 vertical to 4
horizontal.
21
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
POSTS (STANDARD)
1.5
m
(5 f
t.) M
A X.
BEARER VA R
IES
(TRANSOM) OVERLAP OVERHANG
300 mm. 150 mm. (6") MIN.
RUNNER (UNLESS CLEATED)
(12") MIN.
(LEDGER) 300 mm. (12") MAX.
38 mm.
BOARD BEARER (1.5") THK.
(INTERMEDIATE TRANSOM) BEARER
(TRANSOM)
RUNNER
SUPPORT SPACING FOR PLANKS (LEDGER)
38mm (1-½") THICK
BOARD BEARER BEARER POST
(INTERMEDIATE TRANSOM) (TRANSOM) (STANDARD)
POSTS (STANDARD)
2.4
m
(8 f
t.) M
A X.
BEARER VA R
IES
(TRANSOM)
RUNNER
(LEDGER)
50 mm.
BOARD BEARER (2") THK.
(INTERMEDIATE TRANSOM) BEARER
(TRANSOM)
SUPPORT SPACING FOR PLANKS
50mm (2") THICK
22
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
CLEARANCES
Scaffold operations adjacent to overhead power lines are prohibited
unless one of the following conditions are satisfied:
o The power line has been de-energized, relocated, or protective
coverings installed to prevent accidental contact with the lines. It
should be lockout/tagut.
o Satisfies clearance between scaffold and power lines.
Alternative: 2x the length of the line insulator but never less than 3 meter (10 feet).
23
IV. REQUIREMENTS COMMON TO ALL SCAFFOLDS
STANDARDS
STANDARDS
MOUSING
RING TYPE GIN WHEEL
(PREFERED) HOOK TYPE GIN WHEEL
24
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
TOEBOARD
CLIPS
RUNNER
(LEDGER)
BEARER
(TRANSOM)
RIGHT-ANGLE
(DOUBLE) COUPLER POST
(STANDARD)
HORIZONTAL MEMBERS
No lift height shall exceed 2m.
SCAFFOLD LIFTS
2nd LIFT
1st LIFT
BASE LIFT
(KICKER LIFT)
6"
POSTS RUNNERS BEARERS
(STANDARDS) (LEDGERS) (TRANSOMS)
26
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
HORIZONTAL MEMBERS
Bearers (transoms) and board bearers (intermediate transom) shall be
installed on top of and not underneath supporting runners.
BEARER
(TRANSOM)
RUNNER
(LEDGER)
[UNDERNEATH BEARER]
27
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
HORIZONTAL MEMBERS
Bridging of scaffolds shall be as conceptually as follows:
MAXIMUM 2 BAYS
28
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
HORIZONTAL MEMBERS
Bridging of scaffolds
LADDER
BEAM
MAXIMUM 2 BAYS
IN CERTAIN CASES, CHECK COUPLERS AND DOUBLE POST (STANDARDS) MAY BE REQUIRED
BRACING AND LADDER BEAMS TO OUTER AND INNER POST (STANDARD) LINES
29
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
HORIZONTAL MEMBERS
Bridging of scaffolds
LATTICE /
UNIT BEAM
MAXIMUM 2 BAYS
IN CERTAIN CASES, CHECK COUPLERS AND DOUBLE POST (STANDARDS) MAY BE REQUIRED
BRACING AND LATTICE / UNIT BEAMS TO OUTER AND INNER POST (STANDARD) LINES
30
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
Bracing
Vertical bracing to prevent excessive sway is necessary in both the
transverse and longitudinal direction of all system and tube & coupler
scaffolds for the full height of the scaffold.
Transverse (sectional) braces shall be connected to either posts
(standards) or runners (ledgers) as close as possible to the intersection
(node point) of the bearer (transom) and post (standard).
Longitudinal (façade) braces shall be connected to posts (standards) as
close as possible to the intersection (node point) of the runner (ledger)
and post (standard).
POST (STANDARD) BEARER (TRANSOM) POST (STANDARD)
RUNNER (LEDGER)
4th LIFT
BRACING REPEATED EVERY
5th POST (STANDARD)
1st LIFT
1st LIFT
35o-55o
(TYP.) Base Lift
35o-55o
(TYP.) Base Lift
LONGITUDINAL (FAÇADE) "ZIG-ZAG" BRACING
TRANSVERSE (SECTIONAL) "ZIG-ZAG" BRACING
TUBE & COUPLER SCAFFOLD TUBE & COUPLER SCAFFOLD
31
V. REQUIREMENTS COMMON TO SYSTEM AND TUBE & COUPLER SCAFFOLDS
Bracing
Brace ends may be joined together with end-to-end (sleeve) couplers.
Alternatively, for braces subject to large tension loads, shall be
overlapped & joined with at least two adjustable (swivel) couplers,
DIAGONAL
BRACE
ADJUSTABLE POST
ADJUSTABLE (SWIVEL)
(SWIVEL) COUPLER (STANDARD)
COUPLERS
BEARER
(TRANSOM)
DIAGONAL
BRACE
300 mm (12")
.
Max. (typ.)
NODE POINT
m .
m . in
0 Min M
0
1 ") " ) 300 mm (12")
(4
m
.(
12
LA
P
Max. (typ.) (TYP.)
R
0m VE
30 O
RUNNER
(LEDGER)
32
VI. SYSTEM SCAFFOLDS
System Scaffolds
All system scaffolds shall be erected per manufacturer’s published
instructions and the requirements of G.I. 8.001.
TYPICAL SYSTEM SCAFFOLD BASE IN THE PROCESS OF TYPICAL SYSTEM SCAFFOLD BEING ASSEMBLED
BEING ASSEMBLED AND LEVELED
33
VI. SYSTEM SCAFFOLDS
System Scaffolds
Unless otherwise specified in manufacture’s instruction, all system
scaffold shall be vertically braced in both directions with diagonal braces
(as close to 45º as possible) to its full height for each 10 m.
(33’) of run.
Components from different scaffold manufacturers shall not be
intermixed (except when needed in bracing).
Where specially designed system bracing cannot be used, tube & coupler
scaffold components may be used for bracing of system scaffolds.
Connections shall be tightened with a single hammer blow to the wedge
or cup to provide high degree of rigidity.
Shall be connected by means of one of the following fastening methods:
o Captive wedge system (such as Saudi Scaffolding Factory
(“Kwikstage”)
o Quick-fix system (such as Layher “All-around”)
o Cup locking system (such as SGB “Cuplock”)
System scaffold components shall not be used to construct underhung
scaffolds.
34
VI. SYSTEM SCAFFOLDS
System Scaffolds
The locking-pin
type of system
scaffold shall not
be used.
spigot.
BOLTED SPIGOT
35
VI. SYSTEM SCAFFOLDS
System Scaffolds
Unless otherwise justified and stated in writing by the system scaffold
manufacturer, the maximum number of working levels and total planked
levels shall be as follows:
LIGHT DUTY
Max. Total Number
Maximum Number Maximum Scaffold
Planked/Platformed
of Working Levels Height
Levels
1 9 38 m. (125 ft.)
2 6 38 m. (125 ft.)
3 3 28 m. (91 ft.)
MEDIUM DUTY
Maximum Number Max. Total Number
Maximum Scaffold
of Planked/Platformed
Height
Working Levels Levels
1 7 38 m. (125 ft.)
2 2 24 m. (78 ft.)
36
VII. TUBE AND COUPLER SCAFFOLDS
TYPICAL TUBE & COUPLER SCAFFOLD
PLANKING
(BOARDS)
GUARDRAIL SYSTEM
INCLUDING TOEBOARDS
TOEBOARD
CLIPS
RUNNER
(LEDGER)
BEARER
(TRANSOM)
RIGHT-ANGLE
(DOUBLE) COUPLER POST
(STANDARD)
POSTS
Joint pins or, preferably, end-to-end (sleeve) couplers shall be used for
joints in post (standards). However, joint pins are only designed for
compression load. End-to-end couplers shall be used where tension
(uplift) can be present in a posts (standard) or other scaffold tube.
Joints in posts (standards) shall be staggered. Joints in adjacent posts
shall not occur in the same lift height.
38
VII. TUBE AND COUPLER SCAFFOLDS
ST
L EA ( 4 " )
AT mm.
0
10 RUNNERS
(LEDGERS)
RUNNERS &
BEARERS
INSTALLED
BEARERS
INSIDE POSTS
(TRANSOMS)
[on top of ledger] TYP.
POST
(STANDARD)
BASE PLATES
SILLS (SOLE
BOARDS) BASE LIFT
(KICKER LIFT)
39
VII. TUBE AND COUPLER SCAFFOLDS
RUNNER
(LEDGER) 40
[UNDERNEATH BEARER]
VII. TUBE AND COUPLER SCAFFOLDS
41
VII. TUBE AND COUPLER SCAFFOLDS
TRANSVERSE (SECTIONAL)
“ZIG-ZAG” BRACING
43
VII. TUBE AND COUPLER SCAFFOLDS
BEARER
(TRANSOM)
VERTICAL BRACING
( Transverse “Zigzag” Bracing)
NODE POINT
For wide scaffolds, this (TYP.)
300mm. (12")
transverse “zigzag” bracing Max. (Typ.)
3rd LIFT
shall be shall be repeated
across the width of the POST
4th LIFT
3rd LIFT
MAX. 3OPEN BAYS
2nd LIFT
1st LIFT
35o-55o
(TYP.) Base Lift
4th LIFT
3rd LIFT
MAX. 3OPEN BAYS
2nd LIFT
LIFT HEIGTH
(TYP.)
1st LIFT
35o-55o
(TYP.)
Base Lift
TRANSVERSE (SECTIONAL) "X" BRACING 47
TUBE & COUPLER SCAFFOLD
VII. TUBE AND COUPLER SCAFFOLDS
BRACE CONNECTION
3rd LIFT
2nd LIFT
BRACING REPEATED
EVERY 5th POST
(STANDARD)
1st LIFT
35o-55o
(TYP.) Base Lift
VERTICAL BRACING
(Longitudinal “Facade” Bracing) POST (STANDARD)
BEARER (TRANSOM)
Longitudinal (façade) bracing 8th LIFT
for a scaffold whose length is
7th LIFT
less than its height: The first
diagonal brace shall be installed
6th LIFT
from the base of the first end post
(standard) upward, at between
5th LIFT
35 and 55 degrees, along the
entire length of the scaffold to the 4th LIFT
last end post. Additional diagonal
braces shall then be installed, at 3rd LIFT
between 35 and 55 degrees, in
2nd LIFT
alternating directions (“zigzag”)
across the entire scaffold length
1st LIFT
until reaching the top of the 35o-55o
scaffold. This longitudinal (façade) (TYP.)
Base Lift
bracing shall be installed in
opposite directions, along the TRANSVERSE (FACADE) DIAGONAL BRACING
front (inner) and rear (outer) lines TUBE & COUPLER SCAFFOLD
of posts (standards).
49
VII. TUBE AND COUPLER SCAFFOLDS
1 METER
1 METER
1.0 m
(3'-3") max.
Cover gap
with
plywood
Transverse
Post Spacings
1.0 m
(3'-3") max.
1.2 m
(4') max.
Cover gap
with
plywood
Transverse
Post Spacings
1.2 m
(4') max.
1.0 m
(3'-3") max.
Cover gap
with
plywood
Transverse
Post Spacings
1.0 m
(3'-3") max.
1.2 m
(4') max.
Cover gap
with
plywood
Transverse
Post Spacings
1.2 m
(4') max.
1 METER
1 METER
90
1.2 m
(4') max.
Cover gap
with
plywood
Transverse
Post Spacings
1.2 m
(4') max.
1.2 m
(4') max.
Cover gap
with
plywood
Transverse
Post Spacings
1.2 m
(4') max.
PLAN BRACE
61
VIII. MOBILE AND TOWER SCAFFOLDS
TOEBOARD
WIRE LASHING
(TOP, MIDDLE &
BOTTOM)
PLAN BRACE
UNDER DECK
LADDER SHOULD
BE FIXED TO THE
NARROWER WIDTH
TRANSVERSE
(LEDGER) BRACING
BOTTOM OF LADDER
SUPPORTED 63
VIII. MOBILE AND TOWER SCAFFOLDS
64
VIII. MOBILE AND TOWER SCAFFOLDS
65
IX. FABRICATED TUBULAR FRAME SCAFFOLDS
Fabricated Tubular Frame Scaffolds
66
X. BRACKET SCAFFOLDS
Brackets and Straps
Bracket scaffolds shall only be used to support a Light-duty loading
of 120 kg/m2 (1.2 kN/m2) (25 lb./ft2).
TANK SHELL
TOPRAIL
MIDRAIL (STEEL TUBING OR
(STEEL TUBING OR 3/8" DIA. WIRE ROPE)
3/8" DIA. WIRE ROPE)
PLANKS TOEBOARD
(BOARDS)
S
BRACKET A X. A N K
L
STRAP ft.) M K. P
m (5 ) TH X. KS
BRACKET .5 -½ " A A N
1 M
m (1
8 ft.) K. PL
SPACER 38
m
.4 m ( ") TH
FO
R 2 m (2
5 0m
BRACKET (TANK BUILDER’S) SCAFFOLD FO
R
BRACKET SCAFFOLD
67
X. BRACKET SCAFFOLDS
m m . (3")
DEPTH 75
5 mm (3/16") FILLET D
WEL
WELD TO TANK SHELL
25 mm MAX. SIDE
WELDS
75 mm
(3') MIN. )
m (10"
m
250 n.)
(mi
69
XI. UNDERHUNG SCAFFOLDS
CRITERIA FOR UNDERHUNG SCAFFOLDS
All underhung scaffolds shall be hung from structures capable of
supporting at least 4 times the load imposed on them by the
scaffold.
A guardrail system shall be provided.
71
XI. UNDERHUNG SCAFFOLDS
PUNCHEON
TOPRAIL
TUBE
TOPRAIL
TOEBOARD
MIDRAIL
PREFERRED A c.c. c.c.
PLAN
c.c. c.c. METHOD OF HANGER LADDER BRACE SECTION
LOWER TUBE FIXING BEAM
PLATFORM A-A
c.c. c.c.
B
c.c. c.c.
TRAPEZE
SECTION TUBE
B-B c.c.
c.c.
UNDERHUNG SCAFFOLD
72
XI. UNDERHUNG SCAFFOLDS
“ DON’T SADDLE A
DEAD HORSE”
LIVE END
74
XI. UNDERHUNG SCAFFOLDS
TECNIMONT MATERIAL
SUPPLY
SAP # 1000123277
76
XII. SCAFFOLD TAGGING
TECNIMONT MATERIAL
SUPPLY
SAP # 1000123290
77
XII. SCAFFOLD TAGGING
YELLOW SCAFFOLD
TAG
TECNIMONT
MATERIAL SUPPLY
SAP # 1000123293
Indicates the
scaffold has been
inspected and may
be used only by
workers wearing a
properly anchored
personal fall arrest
system, including a
full body harness
and lanyard.
78
XII. SCAFFOLD TAGGING
PERMANENT MARKER
PENS
TECNIMONT MATERIAL
SUPPLY
SAP # 1000123296
79
SCAFFOLD SAFETY SEMINAR - TECNIMONT
HIGHLIGHTS
81
HIGHLIGHTS
• Certification, similar to riggers’ / crane operators’ certification
English knowledge a must to take the test
80 % – written test passing score (consists 50 items)
100% - performance (actual) test passing score\
10 % current passing rate recorded (certification on going)
Over 60 % of examinees scored less than 60% (to date)
English knowledge a must to take the test
Below 50% obtained score, employee to wait for 6 months to retake
the test
Above 50% obtained score, employee can retest after 3 weeks /
months
Depending on the obtained score, Training Center may consider proofs
of training given to employee to allow him pass the test (flexibility
given)
Arrangement for certification test, only via TECNIMONT proponent
organization and nominee must be a current holder of TECNIMONT
Badge.
TECNIMONT will not train contractors for certification tests
Certification cards good for three (03) years
82
HIGHLIGHTS
83
HIGHLIGHTS
84
HIGHLIGHTS
• Couplers
Riveted type prohibited
BS 1139, EN74 acceptable
85
* * * * * END * * * * *
86
USE OF SHOCK ABSORBING LANYARDS
• Calculating Your Potential Fall Distance
• When using a 6 ft. shock-absorbing lanyard and a full-body
harness
• Add the length of the lanyard (6 ft.) to the maximum elongation
of the shock absorber during deceleration (3 1/2 ft.) to the
average height of a worker (6 ft.).
• Then add a safety factor of 3 ft.
88
NEVER “ride” on ALWAYS use
a mobile
a rope or
(wheeled)
scaffold “bolt bucket”
to raise and
lower small
ALWAYS work
tools and
within the
guardrail system equipment.
Tools and
equipment
must
NEVER be
“bombed”
from a
scaffold.
89
NEVER cut components from a scaffold –
contact the scaffold crew to modify the
scaffold.
90
Maintain good housekeeping and
avoid this
DO NOT use
scaffolding to support
piping
or lifting tackle
91