SHORT COURSE

MOTOR CURRENT SIGNATURE ANALYSIS


FOR
DIAGNOSIS OF FAULTS IN INDUCTION MOTOR DRIVES

Prof Bill Thomson


Director and Consultant
EM Diagnostics Ltd

EM Diagnostics Ltd 20 Greystone Road, Alford, Aberdeenshire, AB33 8TY, Scotland, UK


Tel : +44 (0) 19755 62446 Fax : +44 (0) 19755 62628

e-mail : [email protected] web site : www.mcsainterpreter.com

1
© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised copying, reproduction or amendment of all or part prohibited.
MCSA : MOTOR CURRENT SIGNATURE ANALYSIS
INDUCTION MOTOR DRIVES
• DIAGNOSE PROBLEMS PRIOR TO MOTOR
DRIVE FAILURE

• BROKEN ROTOR BARS


• ABNORMAL AIRGAP ECCENTRICITY
• SHORTED TURNS IN LV STATORS
• ABNORMAL ROTOR DYNAMICS
• PUMP WEAR
• MISALIGNMENT

© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised copying, reproduction or


amendment of all or part prohibited 2
INDUCTION MOTOR DRIVE SYSTEMS

• WHY SO IMPORTANT?

– USA 800,000 MW GENERATING CAPACITY


– 40-50% CONSUMED BY INDUCTION MOTORS

– 320,000MW PLANT SYSTEMS


– 328 MILLION HORSEPOWER

3
Power Pulp & Shipping
Utilities Paper Nuclear
MOD

Oil & Gas Uptime of


Wind
Induction Motor Power
Drive Systems

Chemical DuPont

Refineries Kodak
Mining Transport
Ford
4
8 CW Induction 8 PA Induction 8 ID Induction
Motor Drives Motor Drives Motor Drives

26 Mill Motors
2000 MW Coal Numerous
Induction Motor Fired other
Drives Induction
Motor Drives
Power Station

8 Coal Conveyor 8 Compressor


Induction Motor 8 FD Induction Induction Motor
Drives Motor Drives Drives
5
3 PHASE, SCIM, 6.6kV,
2800kW/3753H.P., 2-POLE,
3570r.p.m., 60Hz,
(Full-load slip = 0.00833 or
0.833%)

6
© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised
copying, reproduction or amendment of all or part prohibited
MOTOR CURRENT SIGNATURE ANALYSIS

• CONDITION MONITORING TECHNIQUE

• INSURANCE POLICY

• TO PREVENT FAILURES

• REDUCE DOWNTIME AND REPAIR COSTS

• PREVENT LOST PRODUCTION

• INCREASE RELIABILITY - PRODUCT DELIVERY

7
MCSA

MCSA : On-Line Monitoring and Analysis of Current to


Assess the Condition of an Induction Motor Drive System

8
APPLICATION OF CURRENT TRANSFORMER CT

9
MCSA Instrumentation

10
Time Domain signals and Current Spectra 11
CURRENT SIGNATURE DUE TO BROKEN BARS

f1 =SUPPLY FREQUENCY (60 Hz)


dB
LOWER UPPER
SIDEBAND
SIDEBAND

Hz

12
SIGNATURE PATTERN DUE TO BROKEN BARS
TWICE SLIP FREQUENCY SIDEBANDS : 2sf1

dB
f1
-2sf1 +2sf1

fsb = f1±2sf1
Hz

IDEALISED
Current Spectrum – Due to
Broken Rotor Bars 13
MCSA ON GM3802A (January, 2002)
3-PH, HV, SCIM, 4155HP/3.1MW, 11kV, 2974r.p.m., 195A 50 Hz
BROKEN ROTOR BAR – LIFTED OUT OF THE SLOT

N=46 dB

© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised copying,


reproduction or amendment of all or part prohibited
14
3-PH, HV, SCIM, 4155HP/3.1MW, 11kV, 2974r.p.m., 195A
BROKEN ROTOR BAR – LIFTED IN THE SLOT
SECONDARY DAMAGE TO HV STATOR

15
© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised copying, reproduction or amendment of all or part
prohibited
3-PH, HV, SCIM, 4155HP/3.1MW, 11kV, 2974r.p.m., 195A
BROKEN ROTOR BAR – LIFTED IN THE SLOT
SECONDARY DAMAGE TO HV STATOR
OFFSHORE OIL PRODUCTION PLATFORM

• TOTAL REPAIR COSTS : $270,000.00


(Removal, transport, repair & re-installation costs)

• THE BOSS IS NOT HAPPY

• PREVENT THIS HAPPENING AGAIN

16
• YOUR JOB IS ON THE LINE
Case History : Large Sea Water Injection Pump

• 3-Phase SCIM, 6600V, 60Hz, 3.6MW/4285h.p.,376A,


3580r.p.m., Star connected

• Full-load slip? s=(Ns-Nr)/Ns = 0.0055(0.55%)

• Sidebands = 2*0.0055*60 = 0.67 Hz (at full load)


or

• Pole Pass Sidebands = 2 *(60 - 59.667) = 0.67 Hz


17
1985 : 20 BARS BROKEN OUT OF 46

18
INDUCTION MOTOR – GEARBOX – COMPRESSOR
3 –phase, 415 V, 134 kW/180 H.P., 210 A, 1485 r.p.m., 50 Hz R = 58

1982 150 A

19
INSPECTION FOLLOWING ON-LINE MCSA

DIE CAST ROTOR FAULTY END RING

© William T. Thomson EM Diagnostics Ltd 2001 - unauthorised copying, reproduction or amendment of all or part prohibited

20

You might also like