Retrofitting of Structures
Retrofitting of Structures
Retrofitting of Structures
RETROFITTING OF STRUCTURES
By Guided By :
Amit Saini (13BCL003) Prof. Tejas Joshi
Kapil Dhabu (13BCL038)
INSTITUTE OF TECHNOLOGY
NIRMA UNIVERSITY
AHMEDABAD-382481
MAY-2015
Flow Of Presentation
Objective
Need of Study
Introduction
Literature Review
Case Study
Conclusion
References
Objective
The objective of this study was to be aware with
the latest trends in the field of retrofication of
structures to come up with some new innovative
ideas for the betterment of the field and also for the
improvement in the structures.
Journal : journals of materials in civil For the retrofitted beams failed in a tensile mode
engineering strength, stiffness, and ductility increased
proportionally with the increase of fibers content.
Literature review
Sr.
No.
Paper details Outcomes
5. Construction Techniques of U-Shape wrap and bottom wrap was good for
Retrofitting for R.C.C. Members improving shear strength as well as for reducing
Using Different Glass Fiber deflection of RC member.
Author : Sandeep G. Sawant, A. B.
Sawant, M. B. Kumthekar, V. V. Even if initial cost of U-Shape wrap is more than
Diwan bottom wrap, The strength of U-Shape wrap beam
was increased by 33.33% as compare to bottom side
Journal : International Journal of wrap beam.
Engineering and Advanced
Technology (IJEAT) Cost of woven roving wrap was more as compare to
single mat and double mat wrap but load carrying
capacity also increases as compare to single mat
and double mat wrap. It was indicated that woven
roving U-Shape wrap is more beneficial and
preferable for Retrofitting.
Woven roving
6 Retrofitting of Reinforced The new technique using the CARDIFRC strip bonding
Concrete Beams with system is a promising method for improving the flexural and
CARDIFRC shear behavior, as well as the serviceability of damaged
concrete beams.
Author :Farshid Jandaghi
Alaee and Bhushan Lal It does not suffer from the drawbacks of the existing
Karihaloo techniques, which are primarily a result of the mismatch in
the properties between the concrete and the repair
Journal : Journal of material.
Composites for Construction
It increases the durability of concrete as CARDIFRC mixes
are very durable because of their highly dense
microstructure.
Sr.
No.
Paper details Outcomes
Why it is used-
1.Easy application.
2. High strength to weight ratio.
3. Resistance to corrosion under the attack of chemicals.
4. Resistance to environmental degradation.
5. Tailorability to adapt any shape.
Cont..
Fiber used-
1. Carbon-High Strength
2. Carbon-High modulus
3. Carbon- Ultra High modulus
4. Aaramid- High Strength
5. E-Glass
Methodology:-
1. Surface grinding to get even surface
2. Apply putty on concave areas.
3. Apply primer to surface.
4. Apply first layer of Saturant by brush or roller.
5. Take FRP sheet, orient it and place on saturant and press it.
6. Apply second sheet and repeat same procedure.
Cont..
Column joint wrapping
Faults occur,
1. High water table in that region
2. Eccentricity of all columns.
3. Loose pockets found in concrete.
4. Sufficient concrete cover is absent for reinforcement.
5. Improper construction techniques.
Cont..
The steps that were suggested and are adopted are as below :
2. All the columns should be jacketed. In the existing structure it was found
that the columns were not centered properly in their position, due to which
they were subjected to unwanted eccentric loads. Also the concrete in
columns, beams, slabs was not compacted properly which created loose
pockets & honey combs in the components. Suitable cover for the
reinforcement was not maintained.
Cont..
Photographs shows the step by step stages of retrofitting work for the considered
Health Building at Nashik
Cont..
1 2 3
Photo 3- Application of chemical admixtures at the joint of new and old concrete
Cont..
Photographs shows the step by step stages of retrofitting work for the
considered Health Building at Nashik