Section 11
Appendix: Equipment Architecture
NORTEL NETWORKS CONFIDENTIAL
BSC Fully Equipped Cabinets
Control Equipment
+5V, 100A 2 3 4 5 10 11 12 13 18 19 20 21
5V PSUE
+12V, 4A PSUC
-12V, 3A D D D D D D D D D D D D
12A EQPD1
D
T
D D D D D D D D
T T T T T T T T
D D D
T T T 5V shelf
FANS
I I I I I I I I I I I I 12A
0 1 22 23 6 7 8 9 14 15 16 17
0 1 0 0 1 2 3 2 4 5V PSUE
M C C C S C S S S S S C S C C S
MPUA D D D D D D D D D D D D
12A EQPD0
M C C P I P I U L I I P I P C I
U S S U C U C P S C C U C U S C
shelf
D
T
D
T
D
T
D
T
D D D D D
T T T T T
D D D
T T T 5V shelf
7 7 O D E D X D E D E 7 D
M 8 8 8 8 8 I I I I I I I I I I I I 12A
U
0A 1A 2A 3A 4A 0 1 0B 1B 2B 3B 4B
5V PSUE
FANS
A R R R R R T T R R R R R
12A EQPI
+5V, 100A
L C C C C C S
A B B B B B C
S C C C C C
C B B B B B 5V shelf
+12V, 4A PSUC B B 12A
-12V, 3A
FAN FAN FAN
FANS
0 1 0 0 1 2 3 2 4 1A 1A 0A 0A A A B B 0B 0B 1B 1B 5V PSUE
12A SWG
M C C C
M C C P
S
I
C
P
S
I
S S S S
U L I I
C
P
S
I
C
P
C
C
S
I MPUB S M M S S E E S S M M S
U S S U
7 7 O
C
D
U
E
C
D
P S C C
X D
U
E
C
D
U S
7
C
D shelf W S S WW C C W W S S W
E W W E C I I C E W W E
5V 5V shelf
E
M 8 8 8 8 8 12A 12A
U
B B B B B
B B B B B B B
FANS S S S S S
S S S S S S S PSUE PSUE
C
B
C
B
C
B
C
B
C
C
B
B
C
B
C
B
C
B
C
B
C
B
C
B
EQPT
1
2 3 4 5 6 7 8 9 0
1
1
1
2
1
3 PSUE
shelf
FAN FAN FAN
NORTEL NETWORKS CONFIDENTIAL 2
BSC 12000 Architecture
To/From OMC-R
C
O MMU SLS MPU MPU SLS
Chain A MMU
N Status Ethernet Status Chain B
T
R CPU- CPU- CPU- CPU- CPU- CPU-
OMU MPU BIFP Inter SUP
O BIFP MPU OMU Multibus II
SUP SUP
L
Multibus II MPUA SIC SIC MPUB
SICX CCS7 D8V D8V CCS7 SICX
V11 64 kb/s V11 64 kb/s
E
ECI A SWC RCB RCB ECI B
Q SWC
U MSW-SWE MSW-SWE
I
Internal PCM/A Internal PCM/B
P
M
E MPU MPU
N Status Status
T ALA TSCB BSCB DDTI
O&M/A bus O&M/B bus
External Loops To/From BTS To/From TCU/MSC
NORTEL NETWORKS CONFIDENTIAL 3
BSC 12000HC Architecture
To/From OMC-R
C
O MMU SLS2 MPU MMU
MPU SLS2
N IDE Chain A Status Ethernet Status Chain B IDE
T
R CPU- CPU- CPU- CPU- CPU- CPU-
OMU MPU BIFP Inter SUP
O BIFP MPU OMU Multibus II
SUP2 SUP2
L
Multibus II MPUA SIC SIC MPUB
SICX CCS7 D8V D8V CCS7 SICX
V11 64 kb/s V11 64 kb/s
E
ECI A SWC RCB RCB ECI B
Q SWC
U MSW-SWE MSW-SWE
I
Internal PCM/A Internal PCM/B
P
M
E MPU MPU
N Status Status
T ALA TSCB BSCB DDTI
O&M/A bus O&M/B bus
External Loops To/From BTS To/From TCU/MSC
NORTEL NETWORKS CONFIDENTIAL 4
TCU Fully Equipped Cabinet
T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU0 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5
T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C 2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU1 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5
T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU2 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5
T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU3 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5
NORTEL NETWORKS CONFIDENTIAL 5
BSC e3 and TCU e3 Physical Presentation
BSC e3 TCU e3
Power Supplies
Fans
Service Service
Area Control Transcoding
Area
Interface Node Node
Interface
(PCM cabling) (PCM cabling)
Fans
Interface Transcoding
Node Node
NORTEL NETWORKS CONFIDENTIAL 6
Node
Control
BSCe3: Control Node
Shelf 0
Shelf 1
1
1
TMU TMU
2
2
- Filler
TMU- - Filler
TMU-
NORTEL NETWORKS CONFIDENTIAL
3
TMU TMU
4
TMU TMU
5
MMS Private
OMU
6
MMS Shared
7
- Filler - ATM SW
8
8
- Filler - ATM SW
MMS Shared
OMU
MMS Private
TMU TMU
TMU TMU
7
TMU TMU
TMU TMU
9 10 11 12 13 14 15
9 10 11 12 13 14 15
SIM A SIM B
BSCe3: Interface Node
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3
LSA LSA LSA
- Filler -
- Filler -
- Filler -
Shelf 1 RC RC RC
SIM A
ATM RM
ATM RM
5 0 4
Shelf 0 LSA LSA LSA
- Filler -
RC RC RC
8k RM
8k RM
CEM 0
CEM 1
SIM B
Interface
Node
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mandatory
for
synchronization
NORTEL NETWORKS CONFIDENTIAL 8
TCUe3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3
Shelf 1 LSA T T LSA LSA T S
RC RC RC
Filler
Filler
R R R I
Transcoding M M M M
Node
0 C C
Shelf 0
T T T LSA E E T T T T T T S
RC M M R R R R R R I
R R R
0 1
M M M M M M M M M M
Transcoding
Node
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mandatory
for
synchronization
NORTEL NETWORKS CONFIDENTIAL 9
S8000 Outdoor BTS
CBCF
(or BCF)
RECAL
(or ALCO)
AC BOX
PA
DRX
F-type
Converters RX-SPLITTER
Battery switch
RF Combiners
PCU
Rectifiers
NORTEL NETWORKS CONFIDENTIAL 10
S8002 BTS
Cooling system CDACS
Rectifiers Power
interconnection
Power (CBCF, RECAL, User)
Controller
Unit
RX Splitters
DRX modules
Couplers
CBCF
Power Amplifiers
User compartment (6 U)
C-PA interconnection
(PA, RECAL, Main interconnection
F power supply, duplexer) (DRX, PA, CBCF, RECAL,
duplexer)
F type
C-AC Main Box
Power Supply
Batteries RECAL board
NORTEL NETWORKS CONFIDENTIAL 11
S12000 Indoor/Outdoor
NORTEL NETWORKS CONFIDENTIAL 12
BCF Architecture
Internal BCF
DRX Private PCM bus CSWM
GTW
P PCM Gateway CSWM PCMI
o To/
w PCMI from
e PCMI BSC
r PCM Interface
A DRX DRX Internal
Radio Logic PCM bus
m
p
l GSM
i Control DSC
Time and Signal.
f bus SYNC
Synchro.
Switching Concentr.
i Management
e
r
O&M bus
ALCO
Alarms
FH bus Concentration
NORTEL NETWORKS CONFIDENTIAL 13
Compact BCF Architecture
CBCF CMCF 2 Private PCM
Switch 8 DRX
CPCMI 6 Private PCM
RECAL
GSM
Time Private PCM
2 Private PCM
Idle Master Slave 8 DRX
Register Processor Processor
Synchro Data Bus RECAL
Function
Extension cabinet 0
Main cabinet
Extension Cabinet 1
2 Private PCM
NORTEL NETWORKS CONFIDENTIAL 14
S2000H BTS Physical Architecture
DRX Main PSU
Heaters
DRX SBCF
MAIN MODULE
BASE
UNIT I/O field I&C
UVGA 2 VGA
HPRF PSU HPRF POWER
SUPPLY MODULE (FP only)
MEU Protection PCB
Batteries, AC BATTERY & INTERFACE
and TELCO Modules MODULE
NORTEL NETWORKS CONFIDENTIAL 15
S2000L BTS Functional Architecture
Abis Interface for BSC/Drop&insert BTS
SBCF
PCM
management
Abis Abis
OML PCM
RSL synchro
External alarms Configuration Software Synchronization
and management management
supervision
External outputs management
Commissioning
& Maintenance Test
Test Interface I&C Terminal management
User Interface
for Test Installation
SBCF/DRX GSM
protocol time
DRX
Software RSL Test
management management management
Radio
Configurations Interface
Synchronization Radio
Supervision
management management
management
NORTEL NETWORKS CONFIDENTIAL 16
SBCF Architecture
SBCF SMCF DRX
DRX
SPCMI
Switching
Matrix Internal
Internal PCM bus
Frame PCM bus DRX DRX
External Aligner PCM Logic Radio
PCM interface
(ABIS (V11)
interface)
Private
PCM
Main bus FH bus
Control
FPGA Unit Debug
(QUICC
Synchronization DRAM
I&C SBCF and Flash)
Terminal GSM time
Ethernet
ALCO 2 driven
Alarms contacts
6 ext alarms Concentration
Temp.
Sensor
NORTEL NETWORKS CONFIDENTIAL 17
NORTEL NETWORKS CONFIDENTIAL