Short circuit
Careless and unaware attitude among
users
Dangerous activities held in building
Overheating
Pipe Leakage
Intentionally burning
Factors contribute to fire
Combustible materials used in building
Combustible goods placed in building
Poor fire fighting system in building
Poor space arrangement
Improper installation of fire fighting
equipments
Malfunction of fire fighting equipments.
Water shortage in fire fighting system
Classes of Fire
When deciding on what fire protection is appropriate for any given situation, it is important to assess the types of fire hazard that may be faced.
Fires that involve flammable solids such as wood, cloth, Water, Dry Chemical Powder,
A
rubber, paper, and some types of plastics Foam
- Building Utilization
- Compartmentation
- Mean of Escape
BUILDING UTILIZATION
Building utilization mean the number of persons
using an undivided space, such as a meeting
room, classroom, auditorium, hotel room or
stadium.
Examples of compartmentation :
1. dividing office area into working place, office equipments
room ( photostate & paper shredder machine ) and storage
area ( papers, files)
2. dividing hospital area into treating room, operation theater
and chemical storage area
COMPARTMENTATION
Method of compartmentation :
The construction of such compartments and all its
components must focus to achieve fire resistance rating
which all components are subject to stringent Listing and
approval use and compliance in countries, where product
certification is mandatory.
Type of component :
1) Fire - resistant elements
2) Interior furnishing / ceiling
FIRE - RESISTANT
ELEMENTS
Spraying
fireproofing to
the ceiling
using a
gypsum based
plaster
MEANS OF ESCAPE
DEFINITION :
Exit access
portion of an exit route that leads to
an exit.
Exit
portion of an exit route that is
generally separated from other areas
to provide a protected way of travel
to the exit discharge.
Exit discharge emergency exit in Stockholm's
part of the exit route that leads underground station "Universitetet"
directly outside or to a street,
walkway, refuge area, public way, or
open space with access to the
outside.
THE DESIGN & CONSTRUCTION OF
THE EXIT ROUTES
Exit routes must be permanent Side-hinged exit doors must be used to
parts of the workplace. connect rooms to exit routes. These doors
must swing out in the direction of exit
travel if the room is to be occupied by more
Exit discharges must lead directly than 50 people or if the room is a high-
outside These exit discharge hazard area.
areas must be large enough to
accommodate the building Exit routes must support the maximum
occupants permitted occupant load for each floor
served, and the capacity of an exit route
may not decrease in the direction of exit
Exit stairs that continue beyond route travel to the exit discharge.
the level on which the exit
discharge is located must be Ceilings of exit routes must be at least 7
interrupted at that level by doors, feet,6 inches high.
partitions, or other effective
means that clearly indicate the An exit access must be at least 28 inches
direction of travel leading to the wide at all points. Where there is only one
exit discharge. exit access leading to an exit or exit
discharge, the width of the exit and exit
Exit route doors must be unlocked discharge must be at least equal to the
width of the exit access. Objects that
from the inside. They must be project into the exit must not reduce its
free of devices or alarms that width.
could restrict use of the exit route
if the device or alarm fails.
THE REQUIREMENTS
FOR EXIT
Exits must be separated by fire
resistant materials - that is,
one-hour fire-resistance rating if
the exit connects three or fewer
stories and two-hour fire-
resistance rating if the exit
connects more than three
floors.
1) Fire Detection
2) Fire Suppression
FIRE DETECTION
FIRE DETECTION SYSTEM
Fire Detection
Device
Manual Call
Point/Break Glass/
Phone
Alarm Trigger
Fire Occurrence
Detected Devices
(Automatic
detector/Heat Detector)
Detected on Control
Panel (Show fire
location in building)
Automatic Connected to
Fire Department
Automatic Fire Alarm Detection
Devices
Heat Detector
FIRE SUPPRESSION
Fire suppression system is used in conjunction with fire detection
system to increase public safety. This system are governed by
the codes under the NFPA (National Fire Protection Association)
1) Fire Extinguisher
* Portable fire extinguisher
* Automatic fire extinguisher
2) Hydrants
* Hose reel
* Wet riser
* Dry riser
* Foam riser
3) Smoke Extraction & Ventilation
FIRE EXTINGUISHER
PORTABLE FIRE
EXTINGUISHER
1) Sprinkler system
2) Gas / Foam system
Direct System
In-Direct System
Thank you
THANK YOU
END OF CHAPTER