SDH Introduction
A brief description of the dedicated SOH bytes (see ITU-T Recommendation G.707 for more information):
A1: Frameword (11110110).
A2: Frameword (00101000).
J0: Regenerator Section Trace [See the Path Trace property sheet].
B1: BIP-8 checksum for the regenerator section [See the Performance chapter].
B2: BIP-24 checksum for the multiplex section [See the Performance chapter].
MS1 and MS2: Media Specific bytes. Used by Nera equipment for Radio Protection Switching communication.
MS3: Media Specific byte. Used by Nera equipment for:
RF-id: [See the Path Trace property sheet].
Remote Reset: [See the Remote Reset property sheet].
ATPC: control signal for ATPC. [See the Power property sheet].
E/M-Wire for E1, E2 and F1. [See the SVCE Telephone property sheet]. E2 is not available for InterLink service telephone.
K1 and K2: Intended to be used for:
Multiplex Section - Automatic Protection Switching.
MS-RDI: Multiplex Section-Remote Defect Indication.
S1: Synchronization status.
M1: Multiplex Section - Remote Error Indication (MS-REI). [See the Performance chapter]
SOH bytes available for user channels (64kb/s, 2Mb/s Wayside, DCC, SVCE telephone):
E1: Intended to be used as Orderwire for regenerator section termination. Default timeslot for SVCE telephone. Can be
used for SVCE telephone, 64kb/s or DCC.
E2: Intended to be used as Orderwire for multiplex section termination. Can be used for SVCE telephone, 64kb/s or DCC.
F1: Intended to be used for V.11 or G703 interfaces. Default timeslot for 64kb/s channels. Can be used for SVCE
telephone, 64kb/s or DCC.
D1-D3: Intended to be used as embedded control channel for regenerator section. Single bytes can be used for 64kb/s or
DCC Line. Multiple bytes can be used for DCC.
D4-D12: Intended to be used as embedded control channel for multiplex section. Single bytes can be used for SVCE
telephone, 64kb/s or DCC. Multiple bytes can be used for DCC.
NU: National Use. The use may be restricted by national regulations. Can be used for SVCE telephone, 64kb/s, DCC or
2Mb/s Wayside.
UN: Unused. Can be used for SVCE telephone, 64kb/s, DCC or 2Mb/s Wayside. The E1, E2 and F1 timeslots can be used
in conjunction with the E/M Wire (MS3 timeslot) when control signals are required (E.g. if using a PABX adapter on a SVCE
Board).
Interlink NL200x
**
**
Modem Board
TRANSCEIVER
INTERLINK INDOOR
MOUNTED
SUPERVISORY BOARD
SVCE BOARD
SmartMetro
SmartManager
NetMaster
Oracle license:
-oracle standard edition one max 10 clients
-oracle standard max 5 clients
-oracle enterprise edition 10 max 10 clients
NetMaster license:
-one client included
Future Plan
Server 1
Application: NEW-NMS
software release: R7L01
Service area: Citylink & NL29x network only (Jawa-Bali-Mdn)
Location: Wismul
Server 2
Application: NET-MASTER
software release: R10F
Service area:Backbone Trans Jawa-Bali (Interlink)
Location: Data center, TBS
Server 3
Application: NET-MASTER
software release: R10F
Service area:Backbone Trans Sulawesi (Interlink)
Location: Data center, TBS