POWER STATION
SAGNIK CHOUDHURY
EE, 4th year
GURU NANAK INSTITUTE OF TECHNOLOGY
Contents
1.Introduction
2.Overview of Mejia Thermal Power Plant
3.Power plant layout
4.Main and Auxiliary Equipment
5.Stepwise operation
Introduction
A Thermal Power Plant converts the heat energy of coal into
electrical energy. Coal is burnt in a boiler which converts water
into steam. The expansion of steam in turbine produces
mechanical power which drives the alternator coupled to the
turbine.Thermal Power Plants contribute maximum to the
generation of Power for any country . Thermal Power Plants
constitute 75.43% of the total installed captive and non-captive
power generation in India . In thermal generating stations coal,
oil, natural gas etc. are employed as primary sources of energy.
Overview of MTPS
Damodar Valley Corporation was established on 7th July 1948.
The MTPS under the DVC is the second largest thermal plant in West Bengal.
It has the capacity of
With the introduction of another two units of 500 MW that is in construction it will be the
Mejia Thermal Power Station is located in the outskirts of Raniganj in Bankura District.
The total power plant campus area is
surrounded by boundary walls and is basically divided into two major parts, first the Power
Plant area itself and the second is the Colony area for the residence and other facilities for
MTPSs employees.
The function of coal handling plant is automatic feeding of coal to the boiler furnace.
A thermal power plant burns enormous amounts of coal.
A 200MW plant may require around 2000 tons of coal daily
Pulverising plant
In modern thermal power plant , coal
is pulverised i.e. ground to dust like
size and carried to the furnace in a
stream of hot air. Pulverising is a
means of exposing a large surface
area to the action of oxygen and
consequently helping combustion.
Pulverising mills are further classified
as:
1. Contact mill
2. Ball mill
Boiler
Boiler is an enclosed vessel in which
Boiler Operation
Reheater
Condenser
Steam after rotating steam turbine comes to condenser. Condenser
refers here to the shell and tube heat exchanger (or surface
condenser) installed at the outlet of every steam turbine in Thermal
power stations of utility companies.
The purpose is to condense the outlet (or exhaust) steam from
steam turbine to obtain maximum efficiency and also to get the
condensed steam in the form of pure water, otherwise known as
condensate, back to steam generator or (boiler) as boiler feed water.
Condensers are classified as:
i)Jet condensers or contact condensers,
ii)Surface condensers.
draught fans
The fans draw warm air from the top
of the boiler house through large air
heaters becoming the primary and
secondary air used for the boiler
combustion process
The air heater warms the incoming
air by transferring heat energy from
the outgoing flue gases
Electro-Static Precipitator
Each boiler has 4 passes with 7 fields each
Cooling Towers
The condensate (water) formed in the
Economizer
Flue gases coming out of the boiler
Steam Turbine
Asteamturbineis a device that
extractsthermal energyfrom
pressurizedsteamand uses it to
domechanical workon a rotating
output shaft.
The steam turbine is a form
ofheat enginethat derives much
of its improvement in
thermodynamic efficiencyfrom
the use of multiple stages in the
expansion of the steam, which
results in a closer approach to
the ideal reversible expansion
process.
Alternator
An alternator is an electromechanical device that converts
Transformers
It is a device that transfers electric energy
SWITCH YARD
SWITCH YARD
Circuit breaker
Isolator
Lightening arrester
Bus bar
Current Transformer
Potential Transformer
CIRCUIT BREAKER
These are used for automatic switching during normal or abnormal conditions .
Specification:
Manufacturer
ABB Limited
SF6
Rated Voltage
245 KV
Rated Current
Under Site Condition of 40 0C
4000 A
2000 A
Rated Frequency
50 Hz
ISOLATOR
These are used to disconnect transmission line under no-load condition for safety,
2000 A
Rated Voltage
245 KV
Rated Frequency
50 Hz
LIGHTENING ARRESTOR
These are used to discharge lightning over voltages and switching over voltages to
earth.
Specification:
Manufacturer
Model No.
ZLA X 25 C
Ref. Standard
IEC 99 4. 1991
Rated Frequency
50 Hz
5 mA
BUS BAR
The conductors to which several incoming and outgoing
metering purpose.
CURRENT TRANSFORMER
These are used to step-down currents for measurement, control &
protection.
Current transformers are used extensively for measuring current
VOLTAGE TRANFORMER
VT measure voltage and this parameter used for protection of
system.
For high voltage CVT (capacitive voltage transformer) is used