100G Technology Presentation
100G Technology Presentation
100G Technology Presentation
A basic introduction
Dr. Paul Brooks
August 2013
Aim
100G flavours
CFP optics
4 x 25G
Router
CFP optics
4 x 25G
Switch
CFP optics 4
x 28G
Router DWDM
Inter-domain OTU4 (or 100GE)
High density,
short reach
40G & 100G
Legacy interfaces
SONET, 10G
40G serial etc
Cloud computing etc
High density,
10G & 40G
DWDM equipment
Segmentation
Enterprise customers
High port density (especially on faceplate)
Today => 48 x SFP+ = 480Gb/s
Telecoms
Port density not critical
1:1 mapping client line side
100G Optics
Main current
approach
SR10 MMF
CXP
100GE
Data Centre
Enterprise
100G
LR4 SMF
CFP
Line Side
OIF MSA
10 (SMF)
CFP
100GE
& OTU4
OIF 5 x 7
module
850 nm
Santur (now
Neophotonics)
1550 nm
Next step
CFP2
2012 Beta
CFP4
2014
Lineside
CFP
ASIC inside
40G Optics
40G
40GE
Data Centre
Enterprise
850 nm
40GE
& OTU3
& OC-768/
STM-256
2011/2012
40GE
& OTU3
& OC-768/
STM-256
QSFP+
2011
Line Side
OIF MSA
OC-768/
STM-64/
OTU3/
OTU3e1/3e2
DWDM
2011+
1310 nm
1550 nm
1550 nm
First Gen CFP is bulky, expensive and power hungry based on 10G electric
interface
Next Gen CFP2/4 is fully based on 25G technology
SMF Space
100G LR4
CFP2
100G LR4/10
CFP
2011
2012
2013
100G LR4
3rd Gen
2014
2012 JDS Uniphase Corporation
2015
~ 2014
1.6 Tb = ~80W
~ 2015
3.2Tb = ~160W
But power density & cooling will remain an issue!
Power is for pluggable optics only, total power will be considerable higher
2012 JDS Uniphase Corporation
10
11
12
CFP4
>6W
Move to 25G I/O electrical interface (direct 1:1 mapping of electrical &
optical lanes).
CFP2 can support native 10 x 10G CFP4 cannot without MLG IC
Gearbox in module replace with CDR
MDIO control S/W re-use from CFP => CFP2 => CFP4
25G electrical I/O is 1st generation technology!
2012 JDS Uniphase Corporation
13
14
15
MDIO
16
Price
CFP (32W)
145mm x 76mm
ASIC inside (~20W)
CFP2 (12W)
106mm x 40mm
ASIC outside
17
17
18
Users need test solutions which give true insight into the
issues of the physical layer.
But denser ICs need framed traffic (Ethernet, OTN etc)
Physical layer applications MUST be protocol aware as
required.
Crosstalk, loss, jitter, bit-slips etc will all need troubleshooting.
More intelligence needed to troubleshoot
Margins become critical
2012 JDS Uniphase Corporation
19
Our Pedigree
October 2009
JDSU releases worlds first 100GE & OTU4 test
set. Unique (patented) features include Lambda
mapping, dynamic skew & MDIO debug.
Product now includes comprehensive OTN
mapping from ODUflex upwards.
December 2011
JDSU releases most compact and
comprehensive 100G field solution, includes
native support for CFP & QSFP+
20
October 2012
JDSU announce worlds 1st CFP2 test solution
21
Paul Brooks
Questions?