HLURB PPT Dec12
HLURB PPT Dec12
HLURB PPT Dec12
REGULATORY BOARD
(SALIENT POINTS: LAWS ENFORCED BY HLURB)
PD 1517
Protection of Legitimate Tenants and Clearance
for Development Proposals and Land Transactions
in Proclaimed Areas for Priority Development
(APD) and Urban Land Reform Zones (ULPZ)
BP 220
(Batas Pambansa) Authorizes the HLURB to
promulgate standards for socialized housing
program
PD 1216
Defines open space in residential subdivision in
compliance with the requirement of PD 957 for
owners/developers to allocate 30% of the gross
area roads, alleys, sidewalks, parks and
recreational spaces
Upon their completion, the roads, alleys,
sidewalks and playgrounds shall be donated by
the owner or developer to the city or municipality
and it shall be mandatory for the LGU to accept it.
The parks and playground may also be donated to
the Homeowners Association of the project with
the consent of LGU. No portion of the parks and
playground donated shall be converted to any
other purpose.
RA 7160
(The Local Government Code of 1991)
Devolves the issuance of approval of subdivision
plans to local government units (LGUs) together
with the implementation of national rules and
standards
RA 7279
The urban Development and housing Act
(UDHA) Provides for a Balanced Housing
Program by requiring owners and developers of
main subdivision projects to provide for a separate
socialized housing project for the underprivileged
and homeless, equivalent to 20% of the area or
cost of the main subdivision project
RA 6552
The Realty Installment Buyer Protection Act
(The MACEDA LAW) Enumerates the rights of a
buyer of a real estate who has paid at least two
years installments, in case of default on
succeeding installments
E.O No. 71
Defines the role of HLURB regarding the
devolution of approval of subdivision plans to the
LGUs. The HLURB will provide the guidelines
and standards
HLURB Resolutions
R-830 dated November 28, 2008 minimum level
of Development Requirement in the issuance of
License to Sell for Subdivision and Condominium
Projects
For Subdivision- land clearing and grubbing,
road racing, earthworks, sub-base and base
preparation and entrance gate
For Condominium Projects civil and
structural works of foundation to include
excavation, pile driving, steel reinforcement and
formworks
Site Criteria
-shall be located in the periphery of the town center or in
area sparsely inhabited and where little hazard to human
life or health could result
Physical Suitability
The memorial park/cemetery must be located
on ground where the water table is not higher
than 4/50 meters below the ground surface as
certified by the National Water Resources Board
(NWRB) and shall not be allowed in
environmentally critical areas as defined in
Proclamation No. 2146
Accessibility
- Served by a road with a minimum with of no
less than 8.0m
- The road right-of-way must be increased as
project size increase
Designed Parameters
1. Design and Dimension of Niche/Vault
1.a the dimension of the niche/vault must
be able to house an urn or receptacle
designed to hold at least 200 cubic inches of
cremated human remains. For ossuary niche,
such shall have a dimension that can
accommodate receptacle for bone remains.
1.b A minimum of 2.0m passageway shall be
provided between interment structures if
proposed to be in grid design
1.c ladder facility shall be provided for
interment and urn retrieval purposes
1.d Material and Construction Requirements
2. Parking
Parking shall be provided at a ratio of 1:50
vaults of 100 parking slots whichever is lower
3. Easement
A 5 meter non-buildable buffer shall be
observed for projects to be located in commercial
zone/area adjoining residential area
4. Prayer Room
A Prayer room shall be provided with a
minimum area of 50 sq.m
5. Comfort Rooms
Every Floor shall be provided with a minimum
of 2 comfort rooms: 1 for male with 2 urinals, 1
water closet and 2 lavatories and 1 for female
with 3 water closets and 2 lavatories.
6. Elevators and Escalators
Elevators shall be provided for projects five (5)
storey and above.
For projects provided with escalators, the angle
of inclination of an escalator shall not exceed 30
degrees for the horizontal. The width between
balustrades shall not be less than 560
millimetres nor more than 1.20 meters as
provide in the National Building Code.
Performance Bond
In any of the ff. forms:
1. A surety bond amounting to 20% of the
development cost of the unfinished portion of
the approved plan issued by duly accredited
bonding
2. Real Estate Mortgage to be executed by the
applicant as mortgagor in favour of the
Republic of the Philippines as Mortgagee, the
latter as represented and acting through
HLURB, over a property other that the subject
property