0% found this document useful (0 votes)
117 views42 pages

Distillation 1

This document provides an overview of distillation column design using rigorous simulation. It discusses the key steps and equations involved, including: - Setting up the MESH equations to model each stage - Estimating condenser and reboiler pressures based on operating conditions - Calculating preliminary design parameters like reflux ratio, number of stages, and feed tray location using shortcut distillation methods - Using a depropanizer column example to demonstrate how these design steps are applied in a simulation.

Uploaded by

Zakariya Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views42 pages

Distillation 1

This document provides an overview of distillation column design using rigorous simulation. It discusses the key steps and equations involved, including: - Setting up the MESH equations to model each stage - Estimating condenser and reboiler pressures based on operating conditions - Calculating preliminary design parameters like reflux ratio, number of stages, and feed tray location using shortcut distillation methods - Using a depropanizer column example to demonstrate how these design steps are applied in a simulation.

Uploaded by

Zakariya Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 42

Distillation Column

Design 1
(Material developed based on Product and Process design
principles:Synthesis, analysis and evaluation, 3e by Seader and
Widagdo)

Distillation column
design
MESH equations

Rigorous analysis requires simultaneous solution of

mathematical relationships for each stage.


MESH equations: (1) Material Balances, (2) Equilibrium

Relationships, (3) Summation Relationships, and (4) Heat


(energy) Balances.

H83 PS1/H84 CFL

Parameters
1) Estimate of condenser and reboiler pressure

Pressure gradient in the column affects the equilibrium


temperature and composition at each stage

Condenser pressure will be selected to enable the cooling of


the vapor with cooling water

2) Reflux Ratio, R
3) Number of theoretical stages, N
4) Feed tray location

H83 PS1/H84 CFL

Column design steps


Preliminary steps:
Calculate Pressure - Splitter operation
Calculate R, N, Nf Short cut distillation
Set up distillation column:
Use the values obtained from the previous

steps to start simulation

H83 PS1/H84 CFL

Depropanizer
example

H83 PS1/H84 CFL

Splitter setup
Preliminary steps:
Define the material stream- Select SRK EOS
Select splitter unit
Select field as your unit set
Install inlet, outlet and energy streams

H83 PS1/H84 CFL

Splitter setup

H83 PS1/H84 CFL

Define splits

Splits are defined based on the distillate specifications

H83 PS1/H84 CFL

Parameter tab

To start with, assume the condenser pressure is

the same as feed pressure and the distillate vapor


fraction as 1.

H83 PS1/H84 CFL

Bottom pressure
Use SET unit to simulate a constant
estimation
pressure drop

This is the variable


we control

H83 PS1/H84 CFL

Bottom pressure
Select the pressure of the stream B and the
estimation
source as stream D (since the pressure of
D is used to calculate the pressure of B

H83 PS1/H84 CFL

Bottom pressure
Assume a constant pressure drop
estimation

H83 PS1/H84 CFL

Bottom pressure
The system is now converged. However, we
estimation
need to recheck the condenser and reboiler
pressure with the consideration of relative
volatility.

H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

Relative volatility
Perform a case study to find the

dependence of pressure on relative volatility


on the new stream. Here, we created a
clone of the feed to work on the case study.

H83 PS1/H84 CFL

Relative volatility

Volatility is defined at its bubble point. So,

make the vapor fraction of feed as zero after


deleting the temperature

Cloned stream
H83 PS1/H84 CFL

Spreadsheet
Define alpha using spreadsheet by importing

K values for the key components

H83 PS1/H84 CFL

Spreadsheet

Import K values for the key components

H83 PS1/H84 CFL

Spreadsheet
Estimate alpha values

H83 PS1/H84 CFL

Case study

Now the case study can be performed using

to study the effect f pressure on alpha

H83 PS1/H84 CFL

Case study
Select the dependent (alpha) and

independent (pressure) variables.

H83 PS1/H84 CFL

Case study
Select the relative volatility and the pressure

of stream 1-2 as the variables

H83 PS1/H84 CFL

Case study

Select the relative volatility and the pressure

of feed 2 as the variables

H83 PS1/H84 CFL

Case study

Now start a case study (alpha). Our objective

is to analyze the dependence of relative


volatility on pressure.

H83 PS1/H84 CFL

Case study

Define the range of pressure at which the

analysis will be conducted. Then run and


view results

H83 PS1/H84 CFL

Case study
Alpha is inversely proportional to pressure.

Since we target high alpha, select low


pressure

H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

Effect of pressure on
Alpha is inversely proportional to pressure. Since
temperature
we target high alpha, select low pressure
The effect of temperature-pressure at condenser

and reboiler should be considered


Use cooling water and steam to save the utility
cost
To enable reboiling with steam, the reboiler
temperature should be lower than 366oF to allow
efficient heat transfer when using high pressure
steam at 150psia.
To use cooling water in condenser, the condenser
temperature should be around 100 -120oF.
H83 PS1/H84 CFL

Effect of pressure on
Add a new case study-Temperature
temperature

H83 PS1/H84 CFL

Effect of pressure on
temperature

Add the temperatures and pressures of streams B and D (Bs pressure is

calculated by SET unit) and variables


Set the temperatures as dependent and pressure as independent variables.

H83 PS1/H84 CFL

Effect of pressure on
Set the same range for pressure as in the
temperature
previous case.

H83 PS1/H84 CFL

Effect of pressure on
View the result by pressing result button.
temperature

H83 PS1/H84 CFL

Effect of pressure on
temperature

Since the Alpha change is only by 0.2 in the pressure range of 205psia and 265psia, we neglect the effects

of alpha and take the benefit of heat exchange instead. Close the window and return to the splitter page.

H83 PS1/H84 CFL

Effect of pressure on
temperature
Even the temperature value at 300psia is well within the limit of not more that 366 oF.
At D-temperature, to fulfill the lower limit of 100 oF, pressure must be about 205psia.

D upper limit is 120oF which limit the pressure to 265psia. Since the pressure lies between 205psia and 265psia, higher

temperature in condenser provides higher driving force and thus requires less area in condenser, an operating pressure of
250psia for condenser is selected.

H83 PS1/H84 CFL

Condenser and
Check the results at the worksheet tab of
reboiler
pressure
splitter

H83 PS1/H84 CFL

Condenser and
Check the results at the worksheet tab of
reboiler
pressure
splitter

H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

Short cut
distillation
Use the pressure estimated in splitter
operation to get estimates on
1)
2)
3)

Reflux Ratio, R
Number of theoretical stages, N
Feed tray location

H83 PS1/H84 CFL

Basic steps
The top product must be in vapor form to

avoid condensing ethane

H83 PS1/H84 CFL

Define key
components
Lightkey in bottoms

9
0.0116
9 365 350 50

Heavykey in distillate

5
0.0221
5 30 191

Actual reflux=1.75*
minimum reflux
(in this case)

H83 PS1/H84 CFL

Results of short cut


distillation

Number of trays = 16
Feed entry tray: 8 or 9

Verify the distillate composition with the target specifica


H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

You might also like