Well Test Analysis
Well Test Analysis
Well Test Analysis
Lecture 21
Rosalind Archer
21.1
qB
kt
pi 162.6
3.22 0.8686s
log
2
kh c t rw
p wf p1hr m log( t )
21.2
where:
qB
m 162.6
kh
k
p1hr p i m log
3.22 0.8686s
2
c t rw
21.3
Analysis procedure
Plot all data!
Fit a straight line to the data, remembering this
solution does not account for radial flow which
may distort the early time data. If the pressure
derivative is also plotted it should be at a
constant level during infinite-acting radial flow
(m=2.303Dp)
Use the slope of the semilog straight line (m) to
determine permeability (k)
Use the value of p(1hr) [read from the semilog
straight line] to determine skin (s).
21.4
21.5
kt
c t
21.6
21.7
k
3.22 0.8686s
log
2
c t rw
21.8
21.9
Analysis procedure
Plot all data (p versus (tp+Dt)/Dt)
Fit straight line to middle time region (early
time is distorted by wellbore storage).
Find slope (m) and extrapolation
of straight line
k
to pws(1hr)
qB
k 162.6
mh
p (1hr) p (Dt 0)
k
p
wf
s 1.151 ws
log
3.22
log
2
m
t p 1
c t rw
21.10
21.11
21.12
k
3.22 0.8686s
log
2
c t rw
21.13
k
s 1.151
log
3.22
2
m
c t rw
21.14
Variable-Rate Tests
pi p wf
n
162.6
(q j q j1 ) log( t t j1 )
kh j1
q n B k
162.6
3.22 0.8686s
log
2
kh c t rw
21.15
Variable-Rate Tests
p i p wf
n (q j q j1 )
162.6
log( t t j1 )
qn
kh j1
qn
B k
3.22 0.8686s
162.6
log
2
kh c t rw
21.16
Variable-Rate Tests
where:
n
(q j q j1 )
j1
qn
log( t t j )
(p i p wf )
y
qn
B
m 162.6
kh
k
b m log
3.22 0.8686s
2
c t rw
21.17
Wellbore Storage
Cs c wb Vwb
A wb
144
Cs
5.615 (g / g c )
Wellbore Storage
21.18
qB
pi
t
24 Cs
Buildup
p ws
qB
p wf (Dt 0)
Dt
24 Cs
21.19
Wellbore Storage
5.615 C
CD
2
2 c t hrw
21.20
21.21
Last Words
21.22
Be consistent!
whatever is characterized as wellbore storage,
radial flow etc on one plot e.g. Cartesian must
be consistent with the presentation of the data
on all other plots e.g. semilog/Horner.