Introduction To Ultrasonic Testing
Introduction To Ultrasonic Testing
Introduction
• This module presents an introduction to the NDT
method of ultrasonic testing.
• Ultrasonic testing uses high frequency sound
energy to conduct examinations and make
measurements.
• Ultrasonic examinations can be conducted on a
wide variety of material forms including castings,
forgings, welds, and composites.
• A considerable amount of information about the
part being examined can be collected, such as the
presence of discontinuities, part or coating
thickness; and acoustical properties can often be
correlated to certain properties of the material.
Outline
• Applications
• Basic Principles of sound generation
• Pulse echo and through transmission testing
• Inspection applications
• Equipment
• Transducers
• Instrumentation
• Reference Standards
• Data presentation
• Advantages and Limitations
• Glossary of terms
Basic Principles of Sound
• Sound
wave.
is produced by a vibrating body and travels in the form of a
The transducer is
capable of both
transmitting and
receiving sound
energy.
Principles of Ultrasonic Inspection
• Ultrasonic waves are introduced into a material
where they travel in a straight line and at a
constant speed until they encounter a surface.
• At surface interfaces some of the wave energy is
reflected and some is transmitted.
• The amount of reflected or transmitted energy can
be detected and provides information about the
size of the reflector.
• The travel time of the sound can be measured and
this provides information on the distance that the
sound has traveled.
Test Techniques
• Ultrasonic testing is a very versatile inspection
method, and inspections can be accomplished in a
number of different ways.
• Ultrasonic inspection techniques are commonly
divided into three primary classifications.
• Pulse-echo and Through Transmission
(Relates to whether reflected or transmitted energy is used)
• Normal Beam and Angle Beam
(Relates to the angle that the sound energy enters the test article)
• Contact and Immersion
(Relates to the method of coupling the transducer to the test
article)
initial
pulse
back surface
echo
crack
echo
crack
plate
0 2 4 6 8 10
UT Instrument Screen
Test Techniques – Pulse-Echo (cont.)
Digital display
showing signal
generated from
sound reflecting
off back surface.
Digital display
showing the presence
of a reflector midway
through material, with
lower amplitude back
surface reflector.
The pulse-echo technique allows testing when access to only one
side of the material is possible, and it allows the location of
reflectors to be precisely determined.
Test Techniques – Through-Transmission
• Two transducers located on 1
opposing sides of the test 1
Digital display
showing received
sound through
material
thickness.
Digital display
showing loss of
received signal
due to presence
of a discontinuity
in the sound field.
Test Techniques – Normal and Angle Beam
• In normal beam testing, the sound
beam is introduced into the test
article at 90 degree to the surface.
• In angle beam testing, the sound
beam is introduced into the test
article at some angle other than
90.
• The choice between normal and
angle beam inspection usually
depends on two considerations:
- The orientation of the feature of
interest – the sound should be
directed to produce the largest
reflection from the feature.
- Obstructions on the surface of the
part that must be worked around.
Test Techniques – Contact Vs Immersion
• To get useful levels of sound energy into a material, the air
between the transducer and the test article must be removed.
This is referred to as coupling.
• In contact testing (shown on the previous slides) a couplant
such as water, oil or a gel is applied between the transducer
and the part.
• In immersion testing, the part and the transducer are place in a
water bath. This arrangement allows better movement of the
transducer while maintaining consistent coupling.
• With immersion testing, an echo from the front surface of the
part is seen in the signal but otherwise signal interpretation is
the same for the two techniques.
1 2
IP 1 IP 2 IP = Initial Pulse
FWE FWE FWE = Front Wall
Echo
BWE BWE DE = Defect Echo
DE BWE = Back Wall
Echo
Defect 0 2 4 6 8 10 0 2 4 6 8 10
Inspection Applications
Some of the applications for which ultrasonic testing may be
employed include:
Gray scale image produced using Gray scale image produced using the
the sound reflected from the front sound reflected from the back surface
surface of the coin of the coin (inspected from “heads” side)
Calibration Standards
Calibration is a operation of configuring the
ultrasonic test equipment to known values. This
provides the inspector with a means of comparing
test signals to known measurements.
Calibration standards come in a wide variety of
material types, and configurations due to the
diversity of inspection applications.
Calibration standards are typically manufactured
from materials of the same acoustic properties as
those of the test articles.
The following slides provide examples of specific
types of standards.
Calibration Standards (cont.)
Thickness calibration
standards may be flat or
curved for pipe and tubing
applications, consisting of
simple variations in ASTM Distance/Area Amplitude
material thickness.
Distance/Area Amplitude
standards utilize flat bottom
holes or side drilled holes to
establish known reflector NAVSHIPS
size with changes in sound
path form the entry surface.
Calibration Standards (cont.)
There are also calibration IIW
standards for use in angle
beam inspections when
flaws are not parallel to
entry surface. DSC DC Rhompas
Signal Amplitude
A-scan presentation
displays the amount of
received ultrasonic energy
as a function of time.
• Relative discontinuity size
can be estimated by
Time
comparing the signal
amplitude to that from a
known reflector.
Signal Amplitude
• Reflector depth can be
determined by the
position of the signal on
the horizontal sweep.
Time
Data Presentation - B-scan
• B-scan presentations
display a profile view
(cross-sectional) of a test
specimen.
• Only the reflector depth in
the cross-section and the
linear dimensions can be
determined.
• A limitation to this display
technique is that reflectors
may be masked by larger
reflectors near the
surface.
Data Presentation - C-scan
• The C-scan presentation displays a plan type view
of the test specimen and discontinuities.
• C-scan presentations are produced with an
automated data acquisition system, such as in
immersion scanning.
• Use of A-scan in conjunction with C-scan is
necessary when depth determination is desired.