Integrated Civil Engineering Design Project (Building Structure Design Example)
Integrated Civil Engineering Design Project (Building Structure Design Example)
Integrated Civil Engineering Design Project (Building Structure Design Example)
Architectural Consideration
Limitation
slope) View/light/Wind climate Flat size, Number of Blocks Podium (Other Facilities Cube house/ Carpark/
Commercial complex)
Budget
Tower
Design
Case A : 45 storey
Lack of flexibility by structural element
End wall should be effectively used as shear wall to provide better stiffness
End wall should be effectively used as shear wall to provide better stiffness
Secondary Beam for gravity load only Aspect ratio = 45x3/19 =7.0
Case B: 15 storey
Case C: 57 storey
Podium Structure
To
confirm the column layout under transfer structure confirm the transfer plate/column layout
To To
confirm the size of transfer structure (e.g. thickness of transfer plate) the tower loading and estimate the size of transfer structure size
Evaluate
Estimate
the member size for model input based on gravity load first and provide some reserve for wind load (say 20 ~40% of wind load) Check top deflection < H/500
Only analysis the critical wind direction Only use the effective members for modeling
For preliminary model, only typical floor is used to simulate the whole tower.
Building height should be maintained
Tower model
Podium model
Element Checking
Check
critical lintel beam force (e.g. check wind shear stress v=V/bd ) critical element force (e.g. wall element under high compression/tension)
Check
Check average gravity load (Total D+L/Gross Floor Area = 15~20 KN/m2
Check total wind shear force = total wind force applied at the building
Q &A