Detail Waterproofing
Detail Waterproofing
Detail Waterproofing
Pipe abraided and primed with Conc.2525 Primer Sonol.Ultra Polyurethane joint sealant
Conipur Tc 458
Fall
Conideck system
FALL
Tile finishes by others Levelling screed by others Air-con discharge pipe 20mm thick cement.sand protective screed
FALL
150
R.C. Slab
Construction grout-shrinkage compensated grout to fill recess Discharge Pipe
3
500
FALL
Drainage cell
Masterpren 2003
Separation layer
Mortar Fillet R.C. Roof Slab Sonoshield HLM 6000 Detailing around pipe Downpipe
50mm thick extruded insulation board Masterpren 2003
Penthouse Unit
Bathroom area
Bathroom area
For brick wall the brick surface must be plastered to receive Barralastic
For shower area, upturn of 1.8m. For non-shower area 0.15m to prevent back splashing of water
Wall tiles
Floor tiles Tile bedding
Discharge pipe
10
100mm
Masterflow 98 to fill box-out opening in the floor pipe abraded to provide a mechanical key
11