GRID
SAM
GSE
1.1) Summary
00-System-Terminology 01-DS AGILE Presentation 02- DS Agile Architecture 06-Computer Maintenance Tool 07-DS Agile OI Overview 08-DS Agile SCE Overview 09-DS Agile SMT Overview 10-DS Agile GTW Overview 11-DS Agile Management 12-Synthesis and Questionary
L1-00-System Terminology - Rev G - P 2
GSE
Summary
1) Generalities
2) Datapoint Terminology
Page 4
Page 9
GSE
SITE
SUBSTATION VOLTAGE LEVEL BAY
MODULE
L1-00-System Terminology - Rev G - P 4
GSE
VOLTAGE LEVEL 2
VOLTAGE LEVEL N
BAY TRANSFO
BAY FEEDER 2
CB 1
Position Control
L1-00-System Terminology - Rev G - P 5
SW 1
Position Control
TR 1
TPI
SW 2
Control
GSE
SUBSTATION Level
GSE
Site Partition => Local/Remote substation Substation Control Uniqueness (nb=1) The Business DB (except Cascade)
Voltage Level Association of Bus Bars for Auto Volt. Regul. Often only one BB (nb 4-5-x) Bay ANSI => 1 CB with associate circuits & protections Association of switchgears/transformers & functions Local/Remote Bay, SBMC, Bay Control Uniqueness Special (coupler, section, feeder, transformer) Often Generic (more easy) Bay belongs to only one C264 Module Primary Electric Device, ANSI functions, Group of DP Special (CB, disconnector, transformer, AR, Sync) Often Generic (DPS/DPC association possible)
Data Point
Real Time information (95% electric) At any level
L1-00-System Terminology - Rev G - P 7
GSE
Summary
1) Generalities
2) Datapoint Terminology
1) Generalities
Page 4
Page 9
GSE
2) Datapoint Terminology
REAL TIME DATA = DATAPOINTS Several KIND of DP
SPS DPS MPS MV TPI DM SCT DCT SPC DPC SP
L1-00-System Terminology - Rev G - P 9
Single Point Status Double Point Status Multiple Point Status Measurement Value Tap Position Indication Digital Measurement Single CounTer Double CounTer Single Point Control Double Point Control Set Point
MEASUR. &
COUNTERS BCR_ST
FSS
Force (auto/Manu) an Invalid DP Suppress (Make DP invalid) Substitute (Force the Status/Value of DP)
Threshold
3) Hardware/IED
DE
GSE
2.3) Controls
Station Operator Right / Gateway channel in control Remote/Local Station Device operating mode (operational, not stand-by) Control Uniqueness Station (GOOSE) Topological ILK Bay Control Uniqueness Bay Remote/Local Bay (order running)
Module (switch, transformer..) Current Module State/Value Bay interlock open/close (including module specific conditions) Locking Auto/Manu Dependency (automation running) Recuperation Time
Inner Simple Built-in Automation Output / feedback input Delays. Physical SBO, Direct Execute, 3 phases, Communication IED
L1-00-System Terminology - Rev G - P 12
GSE
www.alstom.com
GRID
SAM
GSE