Distillation Column Design
Distillation Column Design
Distillation Column Design
(Material developed based on Product and Process design principles:Synthesis, analysis and evaluation, 3e by Seader and Widagdo)
Parameters
1) Estimate of condenser and reboiler pressure
2) Reflux Ratio, R
Pressure gradient in the column affects the equilibrium temperature and composition at each stage Condenser pressure will be selected to enable the cooling of the vapor with cooling water
Depropanizer example
Splitter setup
Preliminary steps:
Define the material stream- Select SRK EOS Select splitter unit Select field as your unit
Tools-Preferences-variables-
units
Install inlet, outlet and energy streams
Splitter setup
Define splits
Parameter tab
To start with, assume the condenser pressure is the
to recheck the condenser and reboiler pressure with the consideration of relative volatility.
Relative volatility
We need to estimate relative volatility. We need to
Relative volatility
Perform a case study to find the dependence of
pressure on relative volatility on the new stream. Here, we created a clone of the feed to work on the case study.
Relative volatility
Volatility is defined at its bubble point. So, make
Spreadsheet
Define alpha using spreadsheet
Spreadsheet
Import K values for the key components
Spreadsheet
Import K values for the key components
Spreadsheet
Import K values for the key components
Spreadsheet
Import K values for the key components
Spreadsheet
Estimate alpha values
alpha prop-but
Databook
Now the case study can be performed using
databook (control+D)
Databook
Open the variables in databook
Databook
Select the relative volatility and the pressure of feed
2 as the variables
Databook
Select the relative volatility and the pressure of feed
2 as the variables
Databook
Now start a case study (alpha). Our objective is to
Databook
Define the range of pressure at which the analysis
Databook
Alpha is inversely proportional to pressure. Since
we target high alpha, select low pressure The effect of temperature-pressure at condenser and reboiler should be considered Use cooling water and steam to save the utility cost To enable reboiling with steam, the reboiler temperature should be lower than 366oF to allow efficient heat transfer when using high pressure steam at 150psia. To use cooling water in condenser, the condenser temperature should be around 100 -120oF.
previous case.
previous case.
Since the Alpha change is only by 0.2 in the pressure range of 205psia
and 265psia, we neglect the effects of alpha and take the benefit of heat exchange instead. Close the window and return to the splitter page.
H83 PS1/H84 CFL
within the limit of not more that 366oF. At D-temperature, to fulfill the lower limit of 100oF, pressure must be about 205psia. D upper limit is 120oF which limit the pressure to 265psia. Since the pressure lies between 205psia and 265psia, higher temperature in condenser provides higher driving force and thus requires less area in condenser, an operating pressure of 250psia for condenser is selected.
splitter
splitter