Distillation Column Design

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 43
At a glance
Powered by AI
The key takeaways are that distillation column design involves solving material and energy balance equations (MESH equations) simultaneously for each stage, and the main parameters to consider are reflux ratio, number of theoretical stages, feed tray location, and condenser and reboiler pressures.

The main parameters considered in distillation column design are: reflux ratio, number of theoretical stages, feed tray location, and estimates of condenser and reboiler pressures. The pressure gradient in the column affects equilibrium temperatures and compositions at each stage.

The main steps involved in distillation column design are: calculating preliminary pressures and splits, using short-cut distillation to estimate reflux ratio and number of stages, setting up the distillation column in simulation software using the preliminary values, and performing simulation.

Distillation Column Design 1

(Material developed based on Product and Process design principles:Synthesis, analysis and evaluation, 3e by Seader and Widagdo)

Distillation column design


MESH equations
Rigorous analysis requires simultaneous solution of

mathematical relationships for each stage.


MESH equations: (1) Material Balances, (2) Equilibrium

Relationships, (3) Summation Relationships, and (4) Heat (energy) Balances.

H83 PS1/H84 CFL

Parameters
1) Estimate of condenser and reboiler pressure

2) Reflux Ratio, R

Pressure gradient in the column affects the equilibrium temperature and composition at each stage Condenser pressure will be selected to enable the cooling of the vapor with cooling water

3) Number of theoretical stages, N

4) Feed tray location

H83 PS1/H84 CFL

Column design steps


Preliminary steps:
Calculate Pressure - Splitter operation Calculate R, N, Nf Short cut distillation Set up distillation column Use the values obtained

from the previous steps to start simulation

H83 PS1/H84 CFL

Depropanizer example

H83 PS1/H84 CFL

Splitter setup
Preliminary steps:
Define the material stream- Select SRK EOS Select splitter unit Select field as your unit

Tools-Preferences-variables-

units
Install inlet, outlet and energy streams

H83 PS1/H84 CFL

Splitter setup

Select the splitter unit here

H83 PS1/H84 CFL

Define splits

Splits are defined based on the distillate specifications

H83 PS1/H84 CFL

Parameter tab
To start with, assume the condenser pressure is the

same as feed pressure and the distillate vapor fraction as 1.

H83 PS1/H84 CFL

Bottom pressure estimation


Use SET unit to simulate a constant pressure drop

H83 PS1/H84 CFL

Bottom pressure estimation


Use SET unit to simulate a constant pressure drop

This is the variable we control

H83 PS1/H84 CFL

Bottom pressure estimation


Select the pressure of the stream B and the source

as stream D (since the pressure of D is used to calculate the pressure of B

H83 PS1/H84 CFL

Bottom pressure estimation


Assume a constant pressure drop

H83 PS1/H84 CFL

Bottom pressure estimation


The system is now converged. However, we need

to recheck the condenser and reboiler pressure with the consideration of relative volatility.

H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

Relative volatility
We need to estimate relative volatility. We need to

perform a case study to find the dependence of pressure on relative volatility

H83 PS1/H84 CFL

Relative volatility
Perform a case study to find the dependence of

pressure on relative volatility on the new stream. Here, we created a clone of the feed to work on the case study.

H83 PS1/H84 CFL

Relative volatility
Volatility is defined at its bubble point. So, make

the vapor fraction of feed as zero after deleting the temperature

H83 PS1/H84 CFL

Spreadsheet
Define alpha using spreadsheet

H83 PS1/H84 CFL

Spreadsheet
Import K values for the key components

H83 PS1/H84 CFL

Spreadsheet
Import K values for the key components

H83 PS1/H84 CFL

Spreadsheet
Import K values for the key components

H83 PS1/H84 CFL

Spreadsheet
Import K values for the key components

H83 PS1/H84 CFL

Spreadsheet
Estimate alpha values

alpha prop-but

H83 PS1/H84 CFL

Databook
Now the case study can be performed using

databook (control+D)

H83 PS1/H84 CFL

Databook
Open the variables in databook

H83 PS1/H84 CFL

Databook
Select the relative volatility and the pressure of feed

2 as the variables

H83 PS1/H84 CFL

Databook
Select the relative volatility and the pressure of feed

2 as the variables

H83 PS1/H84 CFL

Databook
Now start a case study (alpha). Our objective is to

analyze the dependence of relative volatility on pressure.

H83 PS1/H84 CFL

Databook
Define the range of pressure at which the analysis

will be conducted. Then start and view results

H83 PS1/H84 CFL

Databook
Alpha is inversely proportional to pressure. Since

we target high alpha, select low pressure

H83 PS1/H84 CFL

Time for exercise!

H83 PS1/H84 CFL

Effect of pressure on temperature


Alpha is inversely proportional to pressure. Since

we target high alpha, select low pressure The effect of temperature-pressure at condenser and reboiler should be considered Use cooling water and steam to save the utility cost To enable reboiling with steam, the reboiler temperature should be lower than 366oF to allow efficient heat transfer when using high pressure steam at 150psia. To use cooling water in condenser, the condenser temperature should be around 100 -120oF.

H83 PS1/H84 CFL

Effect of pressure on temperature


Add a new case study-Temperature

H83 PS1/H84 CFL

Effect of pressure on temperature


Add the temperatures and pressures of

streams B and D (Bs pressure is calculated by SET unit) and variables

H83 PS1/H84 CFL

Effect of pressure on temperature


Set the temperatures as dependant and

pressure as independent variables.

H83 PS1/H84 CFL

Effect of pressure on temperature


Set the same range for pressure as in the

previous case.

H83 PS1/H84 CFL

Effect of pressure on temperature


Set the same range for pressure as in the

previous case.

H83 PS1/H84 CFL

Effect of pressure on temperature


View the result by pressing result button.

H83 PS1/H84 CFL

Effect of pressure on temperature

Since the Alpha change is only by 0.2 in the pressure range of 205psia

and 265psia, we neglect the effects of alpha and take the benefit of heat exchange instead. Close the window and return to the splitter page.
H83 PS1/H84 CFL

Effect of pressure on temperature


Even the temperature value at 300psia is well

within the limit of not more that 366oF. At D-temperature, to fulfill the lower limit of 100oF, pressure must be about 205psia. D upper limit is 120oF which limit the pressure to 265psia. Since the pressure lies between 205psia and 265psia, higher temperature in condenser provides higher driving force and thus requires less area in condenser, an operating pressure of 250psia for condenser is selected.

H83 PS1/H84 CFL

Condenser and reboiler pressure


Check the results at the worksheet tab of

splitter

H83 PS1/H84 CFL

Condenser and reboiler pressure


Check the results at the worksheet tab of

splitter

H83 PS1/H84 CFL