Chainflex Servo Cable
Chainflex Servo Cable
chainflex type
chainflex cable
CF27.D
PUR 7,5 -20/ +80 10 5 80 198
CF21.UL
PVC 10 -20/ +80 10 50 194 7,5 -5/ +70 10 5 80 190 PUR
CF210.UL
CF270.UL.D
Servo cables
PVC 10 -5/ +70 10 50 188
Jacket Shield Min. bending radius, moved [factor x d] Temperature, moved from/to [C]
Oil-resistant Torsion resistant v max. [m/s] unsupported v max. [m/s] gliding a max. [m/s2]
Page
187
CF210.UL PVC 10 x d
CF210.UL PVC 10 x d
600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 50363-4-1), Class 2. According to IEC 60332-1-2, CEI 20-35, FT1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Style 10989 and 2570, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.
Conductor
Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228). Core insulation Mechanically high-quality, especially low-capacitance TPE mixture. Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Core identification Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Star-quad: yellow, black, red, white Element shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains (following DIN VDE 0281 Part 13). Colour: Pastellorange (similar to RAL 2003) -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2. +5 C to +70 C for use in energy chains with > 50.000 cycles. Minimum bending radius 10 x d. -20 C to +70 C, minimum bending radius 5 x d 10 m/s 50 m/s2 Freely suspended travel distances, Class 1 Medium
Delivery program Part No. 1 signal pair shielded CF210.UL.15.15.02.01 CF210.UL.25.15.02.01 CF210.UL.40.15.02.01 CF210.UL.60.15.02.01(1) 2 signal pairs shielded CF210.UL.15.07.02.02 CF210.UL.25.15.02.02 CF210.UL.40.15.02.02 CF210.UL.60.15.02.02(1)
T/R moved
Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C
External diameter approx. [mm] 12,0 13,5 15,0 16,5 13,5 15,5 17,0 18,5
Copper index [kg/km] 149 203 272 364 169 260 330 425
Weight [kg/km]
(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Image exemplary.
www.igus.eu/en/CF210UL
600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 50363-4-1), Class 2. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Style 10492 and 2570, 1000 V, 80 C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. PVC mixture adapted to suit the requirements in energy chains. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2. +5 C to +70 C for use in energy chains with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 C to +70 C, minimum bending radius 4 x d
T/R moved
T/R fixed
v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant Freely suspended and gliding travel distances up to 100 m, Class 3 Medium
chainflex CF21.UL: cables for energy supply systems in spinneret production. e-chain: Serie E2/000
Image exemplary.
www.igus.eu/en/CF21UL
Test data
Page 50 or www.igus.eu/en/test12
Image exemplary.
1 signal pair shielded CF21.07.05.02.01.UL CF21.15.15.02.01.UL CF21.25.15.02.01.UL CF21.40.15.02.01.UL CF21.60.15.02.01.UL CF21.100.15.02.01.UL CF21.160.15.02.01.UL(1) CF21.250.15.02.01.UL(1) CF21.350.15.02.01.UL(1) 2 signal pairs shielded CF21.07.03.02.02.UL (4 G 0,75+2x(2x0,34)C)C CF21.10.07.02.02.UL (4 G 1,0+2x(2x0,75)C)C CF21.15.07.02.02.UL (4 G 1,5+2x(2x0,75)C)C CF21.25.15.02.02.UL (4 G 2,5+2x(2x1,5)C)C CF21.40.15.02.02.UL (4 G 4,0+2x(2x1,5)C)C CF21.60.15.02.02.UL (4 G 6,0+2x(2x1,5)C)C CF21.100.15.02.02.UL (4 G 10+2x(2x1,5)C)C CF21.160.15.02.02.UL (4 G 16+2x(2x1,5)C)C CF21.250.15.02.02.UL (4 G 25+2x(2x1,5)C)C CF21.350.15.02.02.UL (4 G 35+2x(2x1,5)C)C
Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10+(2x1,5)C)C (4 G 16+(2x1,5)C)C (4 G 25+(2x1,5)C)C (4 G 35+(2x1,5)C)C
External diameter approx. [mm] 11,5 13,0 14,0 15,5 18,0 22,5 24,5 29,5 33,0 12,5 13,5 14,5 17,0 18,5 21,0 24,0 27,0 31,0 34,0
Copper index [kg/km] 95 144 197 256 357 540 716 1056 1557 113 146 175 265 313 409 594 790 1140 1597
Weight [kg/km]
Order example: CF21.15.15.02.01.UL in your desired length (0,5 m steps) CF21.UL chainflex series .15 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs
185 280 312 412 605 925 1165 1466 2090 217 277 324 450 527 712 1025 1270 1910 2175
Please use www.chainflex.eu/en/CF21UL for your online order. Delivery time 24h or today.
Delivery time means time until shipping of goods.
(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
www.igus.eu/en/CF21UL
CF270.UL.D PUR 10 x d
CF270.UL.D PUR 10 x d
600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 status 2009. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Style 10989 and 21223, 1000 V, 80 C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1
T/R moved T/R fixed v max. freely suspended a max. Travel distance
Image exemplary.
www.igus.eu/en/CF270ULD
CF270.UL.D PUR 10 x d
CF270.UL.D PUR 10 x d
Image exemplary.
1 signal pair shielded CF270.UL.15.15.02.01.D CF270.UL.25.15.02.01.D CF270.UL.40.15.02.01.D CF270.UL.60.15.02.01.D CF270.UL.100.15.02.01.D CF270.UL.160.15.02.01.D 2 signal pairs shielded CF270.UL.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF270.UL.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF270.UL.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF270.UL.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF270.UL.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF270.UL.60.15.02.02.D(1) (4 G 6,0+2x(2x1,5)C)C CF270.UL.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF270.UL.160.15.02.02.D(1) (4 G 16,0+2x(2x1,5)C)C CF270.UL.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C CF270.UL.350.15.02.02.D(1) (4 G 35,0+2x(2x1,5)C)C 1 Control triple CF270.UL.15.10.03.01.D(9) (4 G 1,5+(3x1,0)C)C (10) CF270.UL.25.10.03.01.D (4 G 2,5+(3x1,0)C)C 1 Star-quad shielded CF270.UL.60.05.04.D (4 G 6,0+(4x0,5)C)C Without signal pair CF270.UL.15.04.D (4 G 1,5)C CF270.UL.25.04.D (4 G 2,5)C CF270.UL.40.04.D (4 G 4,0)C CF270.UL.60.04.D (4 G 6,0)C CF270.UL.100.04.D (4 G 10,0)C CF270.UL.160.04.D (4 G 16,0)C CF270.UL.250.04.D (4 G 25,0)C CF270.UL.350.04.D (4 G 35,0)C
Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C
External diameter approx. [mm] 12,0 13,5 15,0 16,5 20,5 24,0 11,5 13,0 13,5 15,5 17,0 18,5 22,0 26,0 28,0 35,0 14,0 14,0 16,5 9,0 11,0 12,5 14,5 18,0 21,5 25,5 33,0
Copper index [kg/km] 149 203 272 364 582 855 107 143 169 260 330 425 632 901 1365 1804 160 203 350 82 141 211 306 496 782 1197 1695
Weight [kg/km]
Order example: CF270.UL.25.15.02.01.D in your desired length (0,5 m steps) CF270.UL.D chainflex series .25 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs
246 317 408 521 841 1225 197 251 290 408 506 633 940 1315 1847 2516 288 327 512 147 224 309 434 698 1052 1572 2312
Please use www.chainflex.eu/en/CF270ULD for your online order. Delivery time 24h or today.
Delivery time means time until shipping of goods.
(1) Delivery time upon inquiry. (9) core/core: 50 pF/m, core/Shield: 95 pF/m (10) core/core: 70 pF/m, core/Shield: 115 pF/m Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
www.igus.eu/en/CF270ULD
4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 status 2009. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Style 10492 and 20234, 1000 V, 80 C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1
Core stranding Element shield Inner jacket Overall shield Outer jacket
v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant Nominal voltage Freely suspended and gliding travel distances up to 100 m, Class 3 Medium 600/1000 V (following DIN VDE 0250). Modular design, easy to retrofit: igus E4 energy supply system and chainflex cables.
Image exemplary.
www.igus.eu/en/CF27D
Test data
Page 30 or www.igus.eu/en/test1
Image exemplary.
1 signal pair shielded CF27.07.05.02.01.D CF27.15.10.02.01.D(11) CF27.15.15.02.01.D CF27.25.10.02.01.D(11) CF27.25.15.02.01.D CF27.40.15.02.01.D CF27.60.15.02.01.D CF27.100.15.02.01.D CF27.160.15.02.01.D CF27.250.15.02.01.D CF27.350.15.02.01.D 2 signal pairs shielded CF27.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF27.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF27.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF27.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF27.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF27.60.15.02.02.D (4 G 6,0+2x(2x1,5)C)C CF27.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF27.160.15.02.02.D (4 G 16,0+2x(2x1,5)C)C CF27.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C (1) CF27.350.15.02.02.D (4 G 35,0+2x(2x1,5)C)C 1 Star-quad shielded CF27.15.05.04.D (4 G 1,5+(4x0,5)C)C CF27.25.05.04.D (4 G 2,5+(4x0,5)C)C CF27.40.05.04.D (4 G 4,0+(4x0,5)C)C CF27.60.05.04.D (4 G 6,0+(4x0,5)C)C
Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C
External diameter approx. [mm] 11,5 12,5 13,0 14,0 14,5 16,0 17,5 21,5 24,5 28,5 32,5 12,5 13,5 14,0 16,5 18,0 20,0 23,5 26,0 31,0 33,5 13,0 14,5 16,0 17,5
Copper index [kg/km] 95 130 144 184 199 257 357 540 716 1140 1560 105 152 175 265 314 410 594 790 1200 1597 142 199 256 371
Weight [kg/km]
Delivery program Part No. Without signal pair CF27.07.04.D(1) CF27.10.04.D(1) CF27.15.04.D CF27.25.04.D CF27.500.04.D
175 226 260 297 325 402 580 900 1150 1523 2079 206 265 300 412 485 643 1000 1250 1890 2150 310 348 480 550
Number of cores and conductor nominal cross section [mm2] (4 G 0,75)C (4 G 1,0)C (4 G 1,5)C (4 G 2,5)C (4 G 50,0)C
Weight [kg/km]
(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core
Order example: CF27.15.10.02.01.D in your desired length (0,5 m steps) CF27 chainflex series .15 Code nominal cross section .10 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs
Please use www.chainflex.eu/en/CF27D for your online order. Delivery time 24h or today.
Delivery time means time until shipping of goods.
(1) Delivery time upon inquiry. (11) Phase-out model Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
www.igus.eu/en/CF27D