Time Delay Modules

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Time Delay Relays

Plug-in Time Cubes and Time Delay Modules

Time Cubes : CT2 and CT3

CT-System: CT30, CT32, CT33, CT36

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

CT2 /CT3
Time Cubes

11

Plug-in Time Cubes

PLUGED SIMPLY N BETWEE


0,2 s - 30 min
0,2-3s/min 2-30s/min

0,2 s - 30 min
0,2-3s/min 2-30s/min

Industrial relay Time cube

On delay

E
CT2 (8-pin) CT3 (11-pin)
RELAY
413 58 6
4 1 3 5 6 7 8 119

t
S R on with delay R off S OFF

S R

8- /11-pole Plug-in Time Delay Relay System


The simplest time delay relay sys-tem world-wide, fitting all 8 or 11-pin relay sockets (octal/sub-magnalite). Original time cubes are simply placed between socket and relay without rewiring. In this way, even as a retrofit, all industrial relays can be provided with the required timing functions without additional space being required. The contact connections of the relay on the socket remain through-connected.

RELAY

Off delay

A
41 3 567 8 11 9

413 586

10

<

All new types ..30 (0,2s-30min) are fully compatible with all previous types ..20, ..21 and ..25.

A2 7 Socket

A1 2

A2 10

A1 2

Socket

UC180-265V

UC90-265V

UC90-150V

DC9,5-18V

UC20-65V

Order no.
Function

R on for t S S OFF R off (pulse clipping)

Pulse shaping

Triggering

2 = 8 - pole 3 =11- pole

A2 A1 A2 B1 A1 A2 B1 A1 +
S

CT .. - A 30 / ...
W

U M U M H H

L L L L

S S S S

CT .. - K 30 / ...
CT.. -W30 / ...

Blinker, pulse start

AC/DC

10%

ON

Industrial relay

CT2 / 3

Socket

EC-8
02

EC-11
5
22

6
24

4
12

3
14
10 A 10 A 400 V 300 V Listed

9
34

8
32

Ordering example Time cubes CT2-E30/H Socket EC-8 or CS-8 Relay C2-... Time cubes CT3-E30/H Sockel EC-11 oder C11A Relay C3-...
S3-CT
For Relay C2...C3

EC-8
10 A 400 V

EC-11
10 A 400 V

10 A 10 A 400 V 300 V Listed

Clip

62

HF-33
For Relay* C21...C39

A2

21

11

A1

A2

31

21

11

A1

10

11

58 ( 51* )

25

22

38

38

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

32

30

24

22

14

12

02

CT .. - B 30 / ...

S R on/off periodically according to t S OFF R off

UC

DC

CT .. - E 30 / ...

S (pulse or continuous contact) R on for t no influence on R and t S

MAX

10A 250 V A

One shot leading edge S W t R

S B1

S B1

S R on R off with delay S OFF

CT2

CT3

t t t

OFF

S R

S R

S R

S = Triggering R = Output circuit = switches...

CT-System

1 1

Multifunction Time Delay Relays, Modular

The Comat CT System is modular.


The time delay relays and monitoring relays consist of the plug-in CT electronic module and an 11-pole CT output relay. Both system components can be combined freely with one another. This allows the equipment to be selected optimally for specific use. Subsequent modifications, for example a change from mechanical contacts to solid-state outputs, are possible at any time by simple reconnection. This provides the user a complete, universal system, the high flexibility of which is unique throughout the world. The system socket C12B0 serves as a basis for the vibration-free reception of the electronic module. It has a 4-pole module slot in which the CTmodule also without output relay locks in such a way that it is vibration-free. Contact is via twin knife contacts which ensure optimal contact reliability. With the A2-connector C-A2 plug-in flush in the socket, the neutral conductor (N / ) can be connected as a 10 A bus from socket to socket. This considerably reduces wiring work. Robust terminals for cross-sections up to 4mm2 and generous labelling facilities are other advantages of this practical comat system socket. As variants to the standard socket C12 B0, two identical sockets, but with printed device diagram, are available (C12 B1/2). By clearly identifying the connections, these sockets ensure rapid, error-free and therefore economical wiring. When a service is required, they faciliate fault location. The CT module demonstrates comat's practical experience in the area of industrial electronics. All control and display elements are arranged on the front and are labelled in a selfexplanatory manner for international use. The values set are also clearly legible when the module has been installed. Printed diagrams explain the functions, and the connection scheme directly indicates the appropriate terminals in the system socket. A transparent front cover provides protection from unauthorized misadjustment and additionally locks the module onto the output relay. Triggering is performed with the operating voltage (L1or +). Hence, no potential-free contacts are required. Triggering complies with the machine standards. A parallel connection of other users to B1 is admissible. The 2 voltage ranges UC110-240 V and UC 24-48V have been chosen by comat to ensure a high level of reliability in triggering. They permit use with an AC or DC supply and optimal adaptation to the operating conditions of modern controls. In case of an even broader voltage range, e.g. 24-240V it is often possible to achieve only currents of a few 100A in the trigger circuit B1 with simultaneous low threshold voltages to less than 20 V. This may lead to unintentional triggering due to capacitive/inductive pickups, or faulty switching may occur owing to sufficiently loaded control contacts. During operation, 50V are readily measured on open-ended lines. The consumption of the CT modules comes to less than 1W. The output relays have the complete device diagram, the performance data and the complete order no. on the front, supported by a colour code, which indicates an AC coil with red and a DC coil with blue. The .1 and .2 relays have a safety manual operation facility as a standard feature, which switches the contacts only after a lock has been released (twohand principle). The standard contacts .1 and .3 have proved their worth millions of times in heavy current applications. The contact material AgNi permits a large switching range and thanks to generous dimensioning achieves a high number of cycles. With its high breaking capacity of up to 10 A / 400 V, this contact is a reliable allround contact for use both in mains circuits and in the lower voltage range from 12 V /10 mA. The twin contacts .2 and .4 switch every circuit with two independent reeds. Compared with single contacts, they provide up to 100 times greater safety with regard to the level of possible faulty switchings. In spite of their high breaking capacity of up to 6 A / 250 V, these contacts are particularly suitable for low switching currents and switching voltages down to 1mA / 6 V. The solid-state relays are used instead of mechanical contacts. In the standard version .5, the relay has a potential-free output which switches an AC or DC load in the same way as a mechanical contact. However, it functions without bounce or wear, withstands overloads, has shortcircuit protection and has a practically unlimited life even with full output load. Preferred applications are high switching frequency, for example as repeat cycle timers, flashing bars with bulb load or extreme inductive loads, for example large solenoid valves, couplings, motors, etc. An additional protective wiring of the output or of the load is not necessary in these comat relays for any application. They are completely insensitive in an aggressive atmosphere, for example in the chemical industry, in waste water treatment plants, etc.

RELAYS MODULE

Triggering
.
A2 A1 A2 B1 A1 A2 B1 A1 +
S S

Timer module

Function /triggering E W B

Time range

CT30

Economy timer
3 functions, voltage controlled, output LED. Seismic approved.

0,25 s - 30 min
0,25-3s... 2,5-30min

CT32

Universal timer
7 functions, voltage controlled, time lapse display, blinking. Seismic approved.

E A N K B1 W B E A N L F K G B1 W H B
I P

0,15 s - 60 min
0,15-1,5s... 6-60min

CT33

Universal timer
12 functions, voltage controlled, time lapse display, blinking, high setting accuracy by dial graduation 1:5.

30 ms - 60 h
30-150ms... 12-60h

CT36

Universal repeat cycle timer


Pulse or pause start. t1/ t2 separately settable. Time lapse display t1/ t2.

2x 50 ms - 60 h
2x 50-600ms... 5-60h

F O

G H

Triggering

t2= t1
Note on use

t2=0,5s

Function (page )

TF60 setting (page )

According to the standards Safety of machines e.g. EN 60 204-1, EN 292-2, triggering with A2potential (N / ) is only admissible in exceptional cirumstances. For that reason the comat CT modules are triggered by A1-potential (L / +). This makes them unrestrictedly suitable also for use in machines and systems which must conform with machine or CE guidelines or directives.

(+) S
a)

A1 B1 A2

( ) a) A parallel load at B1
is admissible on all CT30 modules.

Order no. for individual module (without output relay): UC110 - 240 V UC 24 - 48 V CT30 / .... V UC115 V, UC 230 V UC 24 - 48 V CT32 / .... V UC115 V, UC 230 V UC 24 - 48 V CT33 / .... V UC110 - 240 V UC 24 - 48 V CT36 / .... V

CT-System

11

Time Delay Relay assembled (module + output relay)


Contact outputs Solid-state outputs

2x

RELAY

MODUL

.1
MAX

RELAY: C31L /...

.3

RELAY: C33/...

.5

RELAY: C35/...

.7

RELAY: C37/...

3 changeover cont.

2x1 changeover cont.


(with instantan.contact) 10A 250 VA 2)
A

Solid-state output
for AC or DC load 0,8A 10-265 VU

Solid-state output
for DC load

10A 250 VA 1)
9 8 7 5 3 4

5 A 10-30 VD
+
9 8

+
9 8 7 5

RL
17 18

RL

38 36 28 26 18 16

14 12 Y2 Y3 18 16 28 26

9 8 7 5 3 4

3 4

7 5 3

R
MODULE A2 35 25 B1 15 A1

1)

R2

R1 25 MODULE

2)
A2

R
K

MODULE

MODULE

10 11 6 12 1 2
.

10 11 6 12 1 2
B

A2 11 Y1 B1 15 A1

10

11

12 2

B1 A1

10

A2

11

12 2

B1 A1

+
Order no. for module + ouput relay (delivery unit):

Order no. for module + ouput relay (delivery unit):

AC 24, 48,115, 230 V DC 24, 48,110, 220 V


Order no.

AC 24, 48,115, 230 V DC 24, 48,110 V


CT30.3 / .... V

AC110-240 V UC 24-48 V
CT30.5 / .... V

UC110-240 V UC 24-48 V
CT30.7 / .... V

CT30.1 / .... V

AC 24, 48,115, 230 V DC 24, 48,110, 220 V


Order no.

AC 24, 48,115, 230 V DC 24, 48,110 V CT32.3 / .... V AC 24, 48,115, 230 V DC 24, 48,110 V CT33.3 / .... V AC 24, 48,115, 230 V DC 24, 48,110 V
CT36.3 / .... V
A Jumper 5-7 : R2 = R1 B Jumper 6-12 : R2 = S

AC115, 230 V UC 24-48 V CT32.5 / .... V AC115, 230 V UC 24-48 V CT33.5 / .... V AC110-240 V UC 24-48 V
CT36.5 / .... V

UC115, 230 V UC 24-48 V CT32.7 / .... V UC115, 230 V UC 24-48 V CT33.7 / .... V UC110-240 V UC 24-48 V
CT36.7 / .... V
Please refer to chapter Industrial Relays for relay datas. 1) Same relay, but with twin contacts 6A 250VA order no. CT.. .2 /...V 2) Same relay, but with twin contacts 5A 250VA order no. CT.. .4 /...V

CT32.1 / .... V AC 24, 48,115, 230 V DC 24, 48,110, 220 V CT33.1 / .... V AC 24, 48,115, 230 V DC 24, 48,110, 220 V
CT36.1 / .... V

Order no.

Order no.

AC
50/60Hz

UC
AC/DC

DC
10%

System socket C12B0 Figure: with plug-in neutral conductor connector C-A2

The Time Relays CT30.., CT32.., CT33.. and CT36.. consist of modules (incl. cover) and output relays. The socket has to be ordered seperatly. The modules can also be combined with other Comat relays. In this case the relays and the modules have to be ordered seperatly. Please refer to chapter industrial relays for datas.. Order no. for individual ouput relay (without module): Ordering example Timer CT32.1/AC230V Socket C12B0 AC24,48,115,230V DC24,48,110,220V C31/ ...V 3) C31L / ...V 4) AC24,48,115,230V DC24,48,110,220V C33 / ....V

5)

3) To module CT30 (Relay without output LED) 4) To module CT32 36 (L= Relay with output LED) 5) For relay C3... (instead of C31/32, or CT...1/.2): Retaining clip S3-C Front cover FS-R

AC110-240V UC24-48V C35 / ....V

UC110-240V UC24-48V C37 / ....V

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.