1. Overview
NPort 5100 series device servers are compact, palm-sized data communication devices that allow you to control RS-232 (NPort 5110), RS-422/485 (NPort 5130), and RS-232/422/485 (NPort 5150) serial devices over a TCP/IP-based Ethernet. Note: -T indicates an extended temperature model.
2. Package Checklist
Before installing the NPort 5100 series device server, verify that the package contains the following items: 1 NPort 5100 series 1-port serial device server 4 stick-on pads Documentation and software CD Quick Installation Guide Warranty card
Optional Accessory
Notify your sales representative if any of the above items are missing or damaged.
3. Hardware Introduction
As shown in the following figures, NPort 5100 series device servers have one male DB9 port for transmitting RS-232 (NPort 5110), RS-422/485 (NPort 5130), or RS-232/422/485 (NPort 5150) serial data.
Green
Off Link Orange Green Off Tx/Rx Orange Green Off P/N: 1802054000312 1
To view detailed information about NPort Administration Suite, click on the Documents button, and then select NPort 5100 Series Users Guide to open the pdf version of the users guide.
6. Pin Assignments
Ethernet Port Pinouts Pin Number 1 2 3 4 5 6 7 8 9 RS-232 DCD RxD TxD DTR GND DSR RTS CTS --RS-422/485 (4W) TXD-(A) TXD+(B) RXD+(B) RXD-(A) GND --------RS-485 (2W) ----Data+(B) Data-(A) GND ---------
Pin Number 1 2 3 6
7. Specifications
Power Requirements Power Input 12 to 48 VDC Power Consumption NPort 5110: 128.7 mA@12V, 72 mA@24V NPort 5130: 200 mA@12V, 106 mA@24V NPort 5150: 200 mA@12V, 106 mA@24V Operating 0 to 55C (32 to 131F), for standard Temperature models -40 to 75C (-40 to 167F), for -T models Operating Humidity 5 to 95% RH Dimensions 75.2 80 22 mm including (2.96 3.15 0.87 in) ears 52 80 22 mm (2.05 3.15 0.89 in) Serial Line Protection Magnetic Isolation Power Line Protection Regulatory Approvals Pin Number RS-422/485 (4W) 1 TXD-(A) 2 TXD+(B) 3 RXD+(B) 4 RXD-(A) 5 GND 6 --7 --8 --9 --RS-485 (2W) ----Data+(B) Data-(A) GND --------without ears
Pin Number 1 2 3 4 5 6 7 8 9
RS-232 DCD RxD TxD DTR GND DSR RTS CTS ---
15 KV ESD for serial port 1.5 KV for Ethernet Level 2 Burst (EFT), EN61000-4-4 Level 2 Surge, EN61000-4-5 FCC Class A, CE Class A, UL, LVD
www.moxa.com/support The Americas: Europe: Asia-Pacific: China: +1-714-528-6777 (toll-free: 1-888-669-2872) +49-89-3 70 03 99-0 +886-2-8919-1230 +86-21-5258-9955 (toll-free: 800-820-5036)