HTTP WWW - Dgserve HPSV Fitt

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Rate Contract

Government of India Directorate General of Supplies & Disposals Jeevan Tara Building, 5 Sansad Marg New Delhi-110001 Tel Number 23360610/23360537 Rate Contract no. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432 Dated 03-JAN-11

To, RAJ ELECTRICALS 214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ, DELHI, Sub: Rate Contract for supply of HPSV Fittings & Accessories Validity: From 01-JAN-11 To 31-DEC-11 . Ref:(1) This Office Tender Enquiry No. HPSV Fitt./ES-7/RC-A1030000/1211/37 Opened on 09-DEC-10. (2) Your Quotation No. RE/RC:HPSV FITT(T)/2010/880 And Dated 09-DEC-10. Dear Sir, You are hereby informed that your above refered tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This rate contract will be governed by the terms and conditions brought in the Form no. DGS&D 1001 available from dgs&d sales counter on payment of Rs. 50/- .The Rate Contract and the schedules annexed here to shall be the sole repository of this Rate Contract/Transaction. SCHEDULES ANNEXED 1.Schedule "A" Description of stores,prices,duties/taxes. 2.Schedule "B" special conditions of contract / Other information. 3.Schedule "C" Information to DDOs about parallel rate contracts. 4.Annexure - Technical Specification

Yours Faithfully, ( ) Assistant Director(S)/Section Officer/Dy.Director For and on behalf of the purchaser named in the Form DGS&D 1001.

Page 1 of 18

Download Date: 15-NOV-11

COPY TO: 1.The Chief Controller of Accounts,Department of commerce,New Delhi/ COA Mumbai/COA Kolkata,COA Chennai. (Through authentication cell) This issues with the approval of competent authority. 2.Deputy Director General of Supplies & Disposals,Chennai -10 copies each 3.Deputy Director General of Supplies & Disposals,Kolkata -10 copies each 4.Deputy Director General of Supplies & Disposals,Mumbai -10 copies each 5.Deputy Director General (QA),Kolkata -10 copies each 6.Deputy Director General (QA),Chennai -10 copies each 7.Deputy Director General (QA),Mumbai -10 copies each 8.Deputy Director General (QA),DGS&D -10 copies each 9.Inspection Authority ADG(QA) DGS&D New Delhi - 110001. 10.Quality assurance Officer Director (QA) Delhi Directorate/ Mumbai,Chennai/Kolkata. 11.Concurrent Audit 12.MIS Cell 13.Ledger clerk 14.O.L.Section 15.All Direct Demanding Officers as per mailing list maintained by DGS&D.

( ) Assistant Director (S) / Section Officer / Deputy Director FOR DIRECTOR GENERAL OF SUPPLIES & DISPOSALS

Page 2 of 18

Download Date: 15-NOV-11

SCHEDULE - A 1.Rate Contract No.:-HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432 Dated 03-JAN-11 For the Supply of HPSV Fittings & Accessories 2.Advance Rate Contract No.:Dated 3.(a) Name and Full Address of the Firm :RAJ ELECTRICALS 214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ, DELHI, DELHI - 110092 Tel. No. - 22143204/5/6 Fax - 22160513 Email - (b) Name and Full Address of Manufacturer :RAJ ELECTRICALS 214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ, DELHI 110092 (c) Brand: DELITE 4.Validity of Rate Contract: 01-JAN-11 To 31-DEC-11 5.Description of Item, Specification,Unit, Rate --------------------------------------------------------------------------------------------------------------------------------------------Item Model Store Description Unit Rate No. No. (in Rs.) --------------------------------------------------------------------------------------------------------------------------------------------13 DELIGHT Spare Ignitors Type: for 70 Watt Lamps NOS. 26.45 Rs. TWENTYSIX AND PAISE FORTYFIVE ONLY 26.45 Rs. TWENTYSIX AND PAISE FORTYFIVE ONLY 26.45

14

DELIGHT

Spare Ignitors

Type: for 150 Watt Lamps

NOS.

15

DELIGHT

Spare Ignitors

Type: for 250 Watt Lamps

NOS.

Page 3 of 18

Download Date: 15-NOV-11

Rs. TWENTYSIX AND PAISE FORTYFIVE ONLY 16 DELIGHT Spare Ignitors Type: for 400 Watt Lamps NOS. 26.45 Rs. TWENTYSIX AND PAISE FORTYFIVE ONLY 1469.79 Rs. ONE THOUSAN D FOUR HUNDRED SIXTYNINE AND PAISE SEVENTYNINE ONLY 2420 Rs. TWO THOUSAN D FOUR HUNDRED TWENTY ONLY 2648.25 Rs. TWO THOUSAN D SIX HUNDRED FORTYEIGHT AND PAISE TWENTYFIVE ONLY 2888.72 Rs. TWO THOUSAN D EIGHT HUNDRED EIGHTY-

17

DELIGHT

Street Light Fittings with Type: for 70 Watt Tubular Lamps IP-66 Protection

NOS.

18

DELIGHT

Street Light Fittings with Type: for 150 Watt Tubular Lamps IP-66 Protection

NOS.

19

DELIGHT

Street Light Fittings with Type: for 250 Watt Tubular Lamps IP-66 Protection

NOS.

20

DELIGHT

Street Light Fittings with Type: for 400 Watt Tubular Lamps IP-66 Protection

NOS.

Page 4 of 18

Download Date: 15-NOV-11

EIGHT AND PAISE SEVENTYTWO ONLY 6-Terms of Delivery: 7-Excise Duty: 8-Sales Tax: 9-Delivery Period: F.O.R. STATION OF DISPATCH i.e. Delhi / New Delhi Excise Duty shall be chaged extra @ 10.3% CST/VAT SHALL BE CHARGED EXTRA @ 12.5% wITHIN 10 TO 18 WEEKS FROM THE DATE OF RECEIPT OF TECHNICALLY AND COMMERCIALLY CLEAR SUPPLY ORDER. 2008-09 2011.35 LACS 2007-08 2547.77 LACS 2006-07 3731.69 LACS Without Any Limit 98% payment on proof of Inspection and despatch and balance 2% on receipt of stores by consignee in full and good condition NIL FIXED N.A. N.A. NA.A SSI The Chief Controller of Accounts, Deptt. of Supply 16A, AKBAR ROAD New Delhi -110011 For Civil ADG(QA),Jeevan Tara Building,Parliament Street New Delhi For Civil Director(QA), Delhi Directorate, Jeevan Tara Building, 4th Floor, Sansad Marg New Delhi DELHI -110001 M/S RAJ ELECTRICALS 214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ, DELHI-110092. Yes

10(a)-Annual Turnover:

(b)-Monetary Limit(In Rs.): 11-Payment Terms:

12-Slab Discount Clause: 13-Prices: 14-Quantity Offered: 15-Minimum Quantity in Single Supply Order: 16-Minimum order Value in Single Supply Order: 17-Status of the RC Holding Firm: 18-Paying Authority:

19-Inspection Authority:

20-Quality Assurance Officer:

21-Place where the Stores are to be Tendered for Inspection:

22-R/C is DDOs Operated:

With effect from First October two thousand eight ( 01-10-2008 ),all supply order(s) against this Rate Contract must be placed by Direct Demanding Officer(s) on-line through D.G.S&D web site (www.dgsnd.gov.in) (indentor's page) only.
Page 5 of 18 Download Date: 15-NOV-11

Supply order(s) in any other form placed on or after 01-10-2008 shall not be valid and shall not be acted upon by the contractor or any other concerned agencies. DDO shall download the supply order and send an ink signed copy to the concerned paying authority specified in the rate contract through Registered / speed post immediately after on-line placement of Supply Order(s). 23-Packing & Specification : see annexure

( ) Asstt. Director (S) / Section Officer / Dy. Director For and behalf of the purchaser named in the Form DGS&D 1001.

All the R/C particulars including prices in respect of individual R/Cs are available on DGS&D website which can be accessed by all.The DGS&D website is http://dgsnd.gov.in

Page 6 of 18

Download Date: 15-NOV-11

SCHEDULE - B RC Specification:1 70 Watt HPSV Class IP-66 Street Light Fittings 1.01 Over all Dimension of fitting (LXWXH) (Tolerance -5%) 550mmX250mmX155mm 1.02 Bare weight of fitting in Kg (Min) 3.520 Kg 1.03 Type of gasket used and its specification Neoprene 1.04 Total weight of fitting with fixture but without lamp 5.3 Kg. 1.05 Whether detail dimensional drawing depicting all parts? and colour photograph available with tenderer Yes 1.06 Indicate the pattern of punch marking on flange of ballast for unique identification of product. R1 2 150 Watt HPSV Class IP-66 Street Light Fittings 2.01 Over all Dimension of fitting (LXWXH) (Tolerance -5%) 630mmX280mmX160mm 2.02 Bare weight of fitting in Kg (Min) 4.630 Kg. 2.03 Type of gasket used and its specification Neoprene 2.04 Total weight of fitting with fixture but without lamp 7.32 Kg 2.05 Whether detail dimensional drawing depicting all parts? and colour photograph available with tenderer Yes 2.06 Indicate the pattern of punch marking on flange of ballast for unique identification of product. R1 3 250 Watt HPSV Class IP-66 Street Light Fittings 3.01 Over all Dimension of fitting (LXWXH) (Tolerance -5%) 700mmX310mmX180mm 3.02 Bare weight of fitting in Kg (Min) 5.340 Kg. 3.03 Type of gasket used and its specification Neoprene 3.04 Total weight of fitting with fixture but without lamp 9.25 Kg. 3.05 Whether detail dimensional drawing depicting all parts? and colour photograph available with tenderer Yes 3.06 Indicate the pattern of punch marking on flange of ballast for unique identification of product. R1 4 400 Watt HPSV Class IP-66 Street Light Fittings 4.01 Over all Dimension of fitting (LXWXH) (Tolerance -5%) 700mmX315mmX190mm 4.02 Bare weight of fitting in Kg (Min) 5.350 Kg. 4.03 Type of gasket used and its specification Neoprene 4.04 Total weight of fitting with fixture but without lamp 10.95 Kg. 4.05 Whether detail dimensional drawing depicting all parts? and colour photograph available with tenderer Yes 4.06 Indicate the pattern of punch marking on flange of ballast for unique identification of product.
Page 7 of 18 Download Date: 15-NOV-11

R1

Page 8 of 18

Download Date: 15-NOV-11

SCHEDULE - C List of Parallel Rate Contract For HPSV Fittings & Accessories Sr.No. 1 NAME & FULL ADDRESS OF FIRM INDUSTRIAL KALINGA 6/3&4,Katori Mill,Rajender Nagar Indl.Area,G.T.Road Sahibabad UTTAR PRADESH 201007 2 LITON LIGHTING INDUSTRY R/C NO & DATE HPSV Fitt./ES-7/RCA1030000/1211/37/03242/1430 03-JAN-11

HPSV Fitt./ES-7/RCK.No. 22/6/1, Peepal Wali Gali, Gali No.9, Samaypur A1030000/1211/37/04512/1431 03-JAN-11 Badli, Delhi DELHI 110042 HPSV Fitt./ES-7/RCA1030000/1211/37/05455/1442 03-JAN-11

TWINKLE LUNINAIRES PVT LTD C-59, Preet Vihar, Vikas Marg, Delhi Delhi DELHI 110092

TWINKLE INDUSTRIES C-59, Preet Vihar, Vikas Marg, Delhi, DELHI 110092

HPSV Fitt./ES-7/RCA1030000/1211/37/05454/1444 03-JAN-11

LORD KRISHNA ELECTRONIC INDUSTRIES 23-24 KRISHAN KUNJ, LAXMI NAGAR, DELHI DELHI 110092

HPSV Fitt./ES-7/RCA1030000/1211/37/NA071/1438 03-JAN-11

ELECTROCINE INDUSTRIES 56/18, Site-IV, Indl Area, Sahibabad, Ghaziabad Ghaziabad UTTAR PRADESH 201010

HPSV Fitt./ES-7/RCA1030000/1211/37/04739/1433 03-JAN-11

COMMANDER ELECTRICALS D-14, 15, 114 & 115, Shreenath Industrial Estate, S. No. 197, B/H Voltas, Dadra Check Post Dadra DADRA NAGAR HAVELI 396230

HPSV Fitt./ES-7/RCA1030000/1211/37/05761/1427 03-JAN-11

SATYA ENGINEERING WORKS PVT. LIMITED A-111, Mangol Puri Indl. Area, Phase-II,

HPSV Fitt./ES-7/RCA1030000/1211/37/04681/1439 03-JAN-11

Page 9 of 18

Download Date: 15-NOV-11

New Delhi DELHI

110034

HPSV Fitt./ES-7/RCA1030000/1211/37/04681/1439 03-JAN-11 HPSV Fitt./ES-7/RCA1030000/1211/37/04793/1440 03-JAN-11

FLORIDA ELECTRICAL INDUSTRIES LTD. B-147, Maya Puri Industrial Area, Phase-1 New Delhi DELHI 110064

10

JAIN INDUSTRIAL LIGHTINGS CORP. B-70/22, DSIDC Industrial Complex, Lawrence Road, Delhi-110035 DELHI 110035

HPSV Fitt./ES-7/RCA1030000/1211/37/05459/1436 03-JAN-11

11

ARUN ELECTRICALS 1/5, Khandsa Road, Gurgaon-122001 Gurgaon HARYANA 122001

HPSV Fitt./ES-7/RCA1030000/1211/37/04297/1446 03-JAN-11

12

SUNEET APROTECH (P) LTD., 2094/1, Gali No. 17, Prem Nagar, New Delhi DELHI 110008

HPSV Fitt./ES-7/RCA1030000/1211/37/05047/1441 03-JAN-11

13

ELTON ELECTRICALS PRIVATE LIMITED 1759, Modern Industrial Estate, Bahadurgarh, Bahadurgarh HARYANA 124507

HPSV Fitt./ES-7/RCA1030000/1211/37/04432/1443 03-JAN-11

14

RAJ ELECTRICALS 214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ, DELHI, DELHI 110092

HPSV Fitt./ES-7/RCA1030000/1211/37/05807/1432 03-JAN-11

15

ATLAS INDUSTRIES 71, S.S.I. Laghu Udyog Nagar, G.T. Karnal Road, Delhi, DELHI 110033

HPSV Fitt./ES-7/RCA1030000/1211/37/05601/1445 03-JAN-11

16

MAMTA PRODUCTS D-26, DSIDC Shed, Jhilmil Colony, Shahdara Delhi, DELHI 110095

HPSV Fitt./ES-7/RCA1030000/1211/37/05204/1437 03-JAN-11

17

LUXOLITE INDUSTRIES A-2/25, Site-IV, Sahibabad Indl. Area, Distt. Ghaziabad, U.P.

HPSV Fitt./ES-7/RCA1030000/1211/37/05758/1428 03-JAN-11


Download Date: 15-NOV-11

Page 10 of 18

17

GHAZIABAD UTTAR PRADESH 201010

HPSV Fitt./ES-7/RCA1030000/1211/37/05758/1428 03-JAN-11 HPSV Fitt./ES-7/RCA1030000/1211/37/04782/1429 03-JAN-11

18

SINGHANIYA LITE & LUMINARIUES (P) LTD. 12/4, Ist Floor, Subhash Nagar New Delhi DELHI 110027

19

KUKREJA ENGINEERS H-1201, D.S.I.D.C. Narela Industrial Area, Narela Delhi DELHI 110040

HPSV Fitt./ES-7/RCA1030000/1211/37/04842/1434 03-JAN-11

20

MODERN LIGHTING SYSTEMS Unit No.64, Block B-70, Dr. Lohia Industrial Area, Lawrence Road, Delhi DELHI 110032

HPSV Fitt./ES-7/RCA1030000/1211/37/05460/1447 03-JAN-11

21

KOHLI & COMPANY T-5, Okhla Indl. Area, Phase-II, New Delhi DELHI 110020

HPSV Fitt./ES-7/RCA1030000/1211/37/05461/1435 03-JAN-11

22

ULTRA LIGHTING LTD. A-83, G.T. Karnal Road, Industrial Area, Azadpur, Delhi, DELHI 110033

HPSV Fitt./ES-7/RCA1030000/1211/37/05680/1448 03-JAN-11

23

TANEJA SALES CORPORATION A-83, G.T. Karnal Road, Industrial Area, Azadpur, Delhi, DELHI 110033

HPSV Fitt./ES-7/RCA1030000/1211/37/05796/1450 03-JAN-11

NOTE: (1) Before placing supply order, DDOs are advised to check with DGS&D or on the website whether any further RCs have been awarded or amendments to Rate Contract have been issued. (2) All the R/C particulars including prices in respect of individual R/C's are available on DGS&D website,which can be accessed by all. The access code of DGS&D website is http://dgsnd.gov.in.

Page 11 of 18

Download Date: 15-NOV-11

ANNEXURE 1. FITTINGS: The fittings where specified shall be ISI marked to IS: 10322 (Part 5/Sec 3)-1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4) ,IS:10322(Part5/Secl)-1985(Reaffirmed 2005)(Incorporating Amendment Nos. 1,& 2),IS 13383 (Part 2) : 1992( Reaffirmed 2000 ) (Incorporating Amendment No. 1) (for photometric) as applicable and with the following additional requirements. Street Light Fittings shall have photometric efficiency of 65%. Connecting wire from control gear terminal block to lamp holder shall be of 1.1 KV grade, copper conductor XLPE insulated. 2. BALLAST:Ballast shall generally conform to IS : 6616-1982( Reaffirmed 2006) with the following variations:a)At rated voltage power delivered shall not be less than 92.5% and not more than 107.5% of the power delivered by the reference ballast. b)Between 92% and 106% rated voltage, the short circuit current shall be within limits given in IS : 9974 (Part I)-1981(Reaffirmed 2002) (Incorporating Amendment Nos. 1, 2, 3 & 4)under the heading ballast design information. c)Abnormal operation (type test)is to be carried out in association with ignitor and as per ignitor specification and for each ratings.( Firm shall declare the model and manufacturer of ignitor for which their ballast is suitable) d)High voltage test of 5 KV for one minute as a type test and 5 KV for 5 seconds as an acceptance test. NOTE: Firm shall have to use their own make ballst for manufacturing of HPSV fittings 3.IGNITOR: I. Performance requirements between 92% & 106% of rated voltage. (a)Pulse height, (i) 1.8 KV to 2.3 KV-70W HPSV fitting (ii) 2.8 KV to 4.5 KV-150W & above HPSV fittings. (b)Direction & postion not material for the time being . (c)Rise time 2 micro. secs. ( Maximum) (d)Duration 0.9 to 8 micro. sec. (e)Pulse repetition rate: 1 per cycle ref IS: 9974. (f)Subsequent pulse height less than 70%. II. Ignitor shall not pulsate after the lamp has been fully ignited i.e.current though it shall be steady. III. Ignitors wrongly connected shall have not deliterious(adverse)effect on the luminaire. I.TYPE TESTING:.

A. FOR FITTINGS:- Additional requirements of type tests. Temp. rise and voltage increase as per Clause IS : 9974 (Part I)-1981 (Reaffirmed 2002) (Incorporating Amendment Nos. 1, 2, 3 & 4).IS:9974 pt-II should also be referred as applicable. b) High voltage test of 5 KV for 1 Min with all terminals shorted and
Page 12 of 18 Download Date: 15-NOV-11

a)

capacitor removed between terminal wire and earthing. c) High Voltage test of 5 KV for1 Min. between two terminals of lamp and lamp cap (on lamp holders). B. FOR BALLAST. As per IS : 6616-1982( Reaffirmed 2006 ) and specification for ballast with following additional requirements. a) Abnormal operation(Type Test)is to be carried out in association with ignitor and as per ignitors specification and for each rating. Firm shall declare the model and manufacturer of ignitor for which their ballast is suitable. b) High Voltage test of 5 KV for one Min. as a type test. C. FOR IGNITORS. i) Protection against accidental contact. The tests shall be conducted with ballasts of makes offered by the firm in the luminaires/as spares. ii) Moisture resistance, insulation resistance and electric strength (5KV for 1 Min.)The test will be conducted in accordance of IS : 6616 - 1982( Reaffirmed 2006 ) iii) Fault condition. When starting device is operated under fault condition like shorting of its terminal of lamp terminals, there shall be no emission of flame etc.& no accessible part will become live. iv) HEATING TEST; Heat test under normal conditions of operation with lamp at rated voltage & in abnormal condition without lamp at 110% voltage the components shall not exceed the permissible limits of operating temp. After these test and cooling down, the ignitor shall operate normally. v) Performance test for pulse characteristics. Pulse characteristic measured with an appropriate osciloscope with ballast & length of wire as provided by the manufacturer in the fitting upto the lamp terminals. vi) Creepage distance. Test will be conducted in accordance of IS : 6616-1982( Reaffirmed 2001 ). vii) Endurance In this test two ignitors are connected as in normal use associated with an appropriate ballast.The test voltage shall correspond to 1.06 x the rated supply voltage of the ballast. The ignitors are operated in conformity with their marking at the maximum allowable temp. in the fittings and without lamp. In doing so the connections of one of ignitors are loaded by the maximum allowable load capacitance say 1000 or unless otherwise specified while the connections of the other ignitors are left unloaded.After 30 days of continuous test they shall meet the requirement and ignite the lamp. ACCEPTANCE TEST: A FOR FITTING:a. High voltage test of 2.5KV for one minute with all terminals shorted and capacitors removed between terminals wire and earthing. High Voltage of 2.5 KV for one minute between two terminals of lamp cap ( on lamp holders).
Page 13 of 18 Download Date: 15-NOV-11

b. Acceptance test as per

governing specification.

B. FOR BALLAST. In addition to tests referred in the specification the following tests are to be conducted. a. Performance test with lamp, ignitor and ballast. b. Watt loss and cold resistance on random samples drawn as per sampling plan for acceptance tests specified in in IS:6616 .however Sample size would be double of that specified in IS:6616. The value of watt loss at nominal rated current circulating directly and measured by a watt meter of 0.2 pf at an ambient Temperature of 27 degree C shall conform to the following: i) Watt loss shall not exceed the figures as under:For 70 Watts Lamp ballast - 15 Watts maximum For 150 Watts Lamp ballast - 19 Watts maximum For 250 Watts Lamp ballast - 26 Watts maximum For 400 Watts Lamp ballast - 38 Watts maximum ii) Resistance tolerance + 5% to -10% (Tenderers to declare the nominal cold resistance value of winding in their offer). iii) For energy efficient ballasts samples size for acceptance tests shall be double the number of samples as indicated in IS:6616 and tests for limitation of ballast heating will be conducted an acceptance test on each lot, each ballast will be marked with watt loss and S.No. of the ballast. C) FOR IGNITORS. i) To be carried out on 4 samples out of every lot of 1000 Nos. and all sample shall pass. ii) Measurement of pulse height, duration, rise time, pulse rate etc. with the ballast offered. iii)High voltage test at 5 KV for 5 seconds. D) Condensor shall conform to IS : 1569 /1976 (Reaffirmed 2001) (Incorporating Amendment No. 1) and shall be suitable to give a power factor of 0.85 (minimum) E) Lamp holders shall conform to IS: 10276 / 1982(Part I & II) (Reaffirmed 2003).

1. Suppliers shall furnish complete and satisfactory type test certificate as per T/E specification for each item to the concerned DQA at the time of registration & inspection.TTC shall be from any Government laboratory. 2. Lamps shall not be the part of supply.

QA PROCEDURE: The following procedure are incorporated to augment the inspection process:

1. The firms shall furnish detailed drawing along with bill of material of each rating/ variety of HPSV fittings for which they have been awarded DGS&D rate contract. These drawings should also indicate average weight of the fittings (with manufacturing tolerance) and should be in consonance with drawings/ sketches vetted by Lab at the time of type testing . 2. Firms shall declare the source of aluminum die cast body, toughened glass, aluminum reflector and neoprene rubber gasket and make/ model/ rating of bought out electrical components being used in manufacturing/assembly of HPSV fittings. They should also maintain record and proof of periodical testing of critical
Page 14 of 18 Download Date: 15-NOV-11

components. . 3. Firms shall also declare the weight of the finished copper wound ballast, weight of the stamping and its type/ grade, size of winding wire, weight of copper winding wire and cold resistance of winding wire at 20 degree C (all with tolerances) for each rating of HPSV ballast. Value of resistance may be converted as per engineering practice at any required temprature. 4. For re-traceability purpose unique identification mark of the firm and serial number/ lot number shall also be punched on the flange of ballast. In case a firm prefers to punch the lot number, the same should not be repeated for the lot offered for next inspection/ future. 5. Firms shall also keep QA office informed as to when die cast bodies are received by them and ready for painting so that QA officer may be able to verify the process on periodical basis and ensure the quality of casting as per specification. 6. Dimension of fitting shall be as per indicative value given in specification of TP. .Fresh TTC is not required for mere change in dimension / size if fittings being tendered/offered are having greater size in comparison to sizes indicated in sketch of type tested products of different ratings which has been authenticated by lab. How ever if sizes of type tested fittings are more than required value , firms have to offer products accordingly and they are not allowed to reduce sizes. 7. During inspection the QA officers shall also verify the offered stores for their conformance with the declaration made by the firm. The overall dimensions (LxWxH) & weight of the fittings, weight and cold resistance of ballast winding at 20 0C, punched unique identification mark of the firm & lot number and serial numbers of ballasts shall be recorded in the I/notes for the guidance of the consignees with the explicit remark that the stores may be checked for these parameters and deviations if any should be reported for appropriate corrective and preventive action . 8. Samples of items tested out of the lot offered for first inspection are to be retained by firm with detailed identification ( R/C no, rating, date of inspection, TTC no etc) for comparison during subsequent inspection. Retention period of sample should not be less than 24 months since dispatch of last consignment to user against this R/C.

Spare

Ignitors

Specification : Spare Ignitors for luminaires against schedule -66 i.e. IP-66 class (make & type) to be specified and to be supported with test reports. Also refer to GTR Street Light Fittings with IP-66 Protection Specification : Street Light Luminaires, IP-66 Class ISI marked to IS : 10322
Page 15 of 18 Download Date: 15-NOV-11

(Part 5/Sec 3) - 1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4) suitable for HPSV Tubular Lamps(without lamp) with Diecast aluminium housing, reflector made of 1 mm deep drawn brightened and anodized aluminium sheet and as per in detailed specification. i) The fittings shall be ISI marked to IS : 10322 (Part 5/Sec 3) 1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4)& comply with requirements of IS:10322(Part5/Secl)-1985(Reaffirmed 2005)(Incorporating Amendment Nos. 1 & 2),IS 13383 (Part 2) : 1992( Reaffirmed 2000 ) (Incorporating Amendment No. 1) (for photometric requirements)

ii)Street Light Luminaires suitable for Tubular HPSV Lamps to IS : 9974 (Part I) - 1981(Reaffirmed 2002) (Incorporating Amendment Nos. 1, 2, 3 & 4)IS : 9974 (Part II) - 1981(Reaffirmed 2002) (Incorporating Amendment Nos. 1 & 2)complete with control gear, suitable for operation on 200-220-240 Volts AC, single phase 50 Hz supply and to be used at a height of 8 to 15 meters. iii)The Housing shall be made out of minimum 2.5 mm thick Die Cast Aluminium alloy and shall be in two parts. The lower part of the fixture shall contain Lamp Compartment, Control Gear and Mounting arrangement whereas the upper part of the fixture shall be hinged to the lower part joined together.Lamp Compartment shall contain 1mm +/0.1 mm thick, deep drawn aluminium sheet, reflectr electro-chemically brightened and anodized and minimum 4mm thick toughened glass. The reflector and toughened glass shall be sealed together for IP-66. Protection. The lamp compartment shall also contain holder assembly fixed with the reflector with neoprene/ EPDBM/Siliocone gasket and two Nos. stainless steel latches. The holder assembly shall have also arrangements for adjustment of holder for various Lamp alignment/photometric properties Fixtures shall be suitable for side entry on a pipe bore 40-60 mm. The fixture shall have builtin tilting arrangement of 0 degree to 15 degree suitable for post top mounting on a pipe of 60- 75 mm dia. iv)The Control Gear shall be complete with all accessories such as copper wound Ballast,Condenser, Ignitor , Terminal Block and ceramic skirted lamp holder duly wired up and ready for use but without lamp. Control gear shall be mounted on an easily removable tray wired up to a terminal block and earthing terminal. confirming to IS: 10322 (Part 5/Sec 3) - 1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4)Connecting wire from control gear terminal block to lamp holders shall be 1.1 KV grade, copper conductor XLPE insulated of 1.25 sq mm size All hardware items exposed outside shall be of stainless steel and hardwares used inside shall be zinc coated and passivated. All ferrous parts shall also be properly zinc coated and passivated. v)The HPSV Lamp fitting/fixture, lamp holder compartment shall confirm to IP-66 degree of protection as per IS:12063 /1987 and the control gear compartment shall confirm to IP-65 degree of protection. Gasket should be of neoprene/EPDBMN/Silicone to sustain high temrature and humudity during service period of produc and to avoid dust and rain water . vi)The fittings shall be visually air tight and comply with IP-66 requirements
Page 16 of 18 Download Date: 15-NOV-11

of IS 10322 ( Part I ) : 1982( Reaffirmed 2005 ). Fittings shall have photometric efficiency of 65%. vii.) Dimension of fittings i.e. Length x Width x Height for respective rating should be as under with maximum permissible minus tollerace on dimension of 5%: 70 Watt: 550x250x150 150 Watt: 630x280x160 250 Watt: 690x310x180 400 Watt: 700x315x190 All dimension are in mm and without any restriction on upper limit on dimension. It may be noted that above dimensions are given for homogenity however once dimension declared by firm as per their manufacturing drawing allowable manufacturing tollerance in negative side shall not be more than 5mm which may arise due to shrinkage etc. Drawing/Proforma/Annexure Attached [Click on the following to View/Print ] Inspection Report Performa

Page 17 of 18

Download Date: 15-NOV-11

LIST OF ALL AMENDMENTS For RC No. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432

Sr No. Amendment No. 1 HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432/34361

Amendment Effective Date From 04-JAN-11 03-JAN-11

Amendment In Amendment in Excise Duty,Annexure & Clauses

Page 18 of 18

Download Date: 15-NOV-11

You might also like