SPECIAL FEATURES FRONT PANEL AND TYPES OF CARDS INSTALLATION PROCEDURES SETTING MODE AND FUNCTIONS 1Registration of card (Add one card) 2Deletion and loss of card (Delete one card) 3Change of 8 sets of user's passwords 4Door lock time setting (shunt time) 5Setting identification modes 6Batch registration (add series cards) 7Antitamper output setting 8Changing system password (command) 9Deletion of 8 sets of user's passwords 10Deletion of batch registration (Delete all cards) 11Door opening (using system password) 12The Duress Code Setting INSTALLATION OF PROXIMITY READER 1Connections 2Installation of electric lock and exit push button 3Installation of door sensor, external relay and siren PRECAUTIONS TROUBLESHOOTING 2 2 3 4 4 5 5 6 6 7 7 8 8 9 9 9 10 10 11 12 13 14
Status light ( Green ) Press key light Power light (Red) OK light(Green)
Types of proximity cards The following 3 types of cards are required to register before use.
SC10 : Thin card , thickness 0.8 mm, ISO standard card dimension.Read range 10 cm. It can be printed directly from card printer
SC20 : Thick card , thickness 1.8 mm,ISO standard card dimension. Read range 10 cm. It can be printed directly from card printer.
12345678
SC30 : Key tag, read range 6cm. dimension 5.5L X 7.5H X 3.2W (mm). Ultrasonic connection, waterproof, shock proof.
INSTALLATION PROCEDURES
Refer to appendix (Mounting of reader unit.)
Users could install either 6pin or 5pin connector to see fit. Please refer to item 5 in installation guide on Page 1112 Ensure the power adapter's voltage and polarity are Power supply to the reader. fitted correctly.
NO
YES
Enter system password (4567), then a beep sound and green light appear to enter into setting mode. If there isn't any activation within 20 seconds, this system will automatically escape Enter 1(register the proximity card) or 6(batch registration). Then, register all the use's proximity cards and key tags. When completed, press ro escape form the setting mode. from the setting mode.
Completion of setting
1. Add one card : To register user's card and utilize proximity to register.
PRESS 1
1 BEEP SOUND
PRESS
On the above operation, if "" is being pressed, the card registration activities will be terminated.
2. Delete card : Deletion of user's card (such as loss of card), card number is the 6digit code indicated on the proximity card.
ENTER"# " SYSTEM PASSWOR D"#" STATUS LIGHT ON WITH A BEEP SOUND PRES S 2 1 BEEP SOUND
PRE SS
1 BEEP S OUND
On the above operation if "" is being pressed, the setting modes will be terminated, provided that there isn't any key being entered. Any keyin being done prior to this operation will be deleted. 3. Change of 8 sets of user's password:
ENTER"# " SYSTEM PASSWOR D"#" STATUS LIGHT ON WITH A BEEP SOUND PRES S 3 1 BEEP SOUND
PRE SS
ENTER S ET OF CO DE(18 )
1 BEEP SO UND
Press "" at Enter New 4digit code: (a)If nothing is entered therefore it will terminate change of 8 sets of users password. (b)If new 4digit code is entered, user is required to reenter the new 4digit code again. 6
4. Door lock time setting :Setting proximity reader relay ON time from 0199 seconds. All unlock time has to be filled in 2digit format such as enter 01 as 1 second. Setting 99 seconds as current state (for security system) and 00 second as single hit (for automatic door)
ENTER" " # SYSTEM PASSWOR D"#" STATUS LIGHT ON WITH A BEEP SOUND PRES S 4 1 BEEP SOUND
COMPLETED
PRESS
TERMINATE
5. Setting identification modes: There are 4 sets of dooropening modes. Users could only set one of the identification modes for access control. Its identification mode has been preset to proximity card dooropening. (1) Door opening based on 4digit password (There are a total of 8 sets of user's password), mode number is 1. (2) Proximity card door opening, that is door will open when the card is sensed, mode number is 2. (3) Proximity card and enter 4digit password door opening, mode number is 3. (4) Proximity card or enter 4digit password door opening, mode number is 4.
ENTER" " # SYSTEM PASSWOR D"#"
PRES S 5
1 BEEP SOUND
1 BEEP SOUND
COMPLETED
P RESS
1 BEEP SOUND
TERMINATE
6. Batch registration : Registering multiple cards and cards in series. Enter 6 digit card number, then enter amount of cards, in 4digit format (must be in full 4 digits, such as 100 pcs. , enter 0100). This system can also apply to single card entry.
E NTER" #" S YSTEM PASSWORD "#" STATUS LIGHT ON WITH A BEEP SOUND PRESS 6 1 BEEP SOU ND ENTER FIR ST 6DIGIT CODE
1 BEEP SOUND
1 BEEP SOUND
COMPL ETED
ENTER
1 B EEP SOUND
1 BEEP SOUND
Press "" at enter first 6digit code: (a)If nothing is entered therefore it will terminate Batch registration. (b)If 6digit card number is entered, user will be required to reenter the 6digit card number again. Press "" at enter quantity of cards(4digit): (a)If quantity of cards is not entered, user will be required to reenter the 6digit card number again. (b)If quantity of cards is entered, user will be required to reenter the quantity of cards in 4digit format. 7. Antitamper output setting : This reader has an antitamper output connecting point. There are two detection sources: (1) Damage to the proximity reader(tamper switch). (2) Damage to the door (must add detection wiring such as reed switch). This function can be set whether door detection point is applied to activate the antitamper output: (1) O : ON (2) I : OFF
ENTER" " # SYSTEM PASSWOR D"#" STATUS LIGHT ON WITH A BEEP SOUND PRES S 7 1 BEEP SOUND
1 BEEP SOUND
COMPLETED
PRESS
TERMINATE
8. Change system password : To change system password, this reader's password is being preset at 4567. Please note that this password is necessary to enter into the system setting mode.
PRESS 8
1 BEEP S OUND
PRE SS
1 BEEP SOUND
PRESS
2 BEEP SOU ND
TE RMINATE
System password has been preset at 4567. Users should enter new 4digit system password twice to complete change of system password.
9. Deletion of 8 sets of user's password : Please note that this function will delete all the 8 set of user's passwords and cannot be retrieved.
PRESS 9
1 BEEP S OUND
PRESS 3
1 BEEP SOUND
CO MPLETED
10. Delete all cards : Please note that this function will delete all registered card and cannot be retrieved.
EN TER" #" SYSTEM PASSWORD "#"
PRESS 9
1 BEEP SOU ND
PRESS 9
1 BEEP SOUND
COMPLETED
PRESS 0
1 BEEP SOU ND
PRESS 0
OPEN DOOR
COMPLETED
PRESS 0
1 BEEP SOUND
PRESS 8
1 BEEP SOUND
TERMINATE
10
8PIN CONNECTOR
AntiTamper switch,common contact AntiTamper switch,normally open contact Reserved AntiDamage alarm output AntiDuress alarm output Door detection sensor point 1 Door detection sensor point 2 GND
6PIN CONNECTOR
DC+12V GND Door control relay.Dry contact(N.O.) Door control relay.Dry contact(N.C.) Door control relay.Dry contact(COM.) Exit push button
Blue Blue
Door open relay contact rating DC12V/ 3A Tamper switch contact rating DC24V / 0.5A Door bell switch contact rating AC125V /3A
11
2. Installation of electric lock and exit push button: A. Electric lock(fail secure type)and reader.
EXIT PUSH BUTTON ELECTR IC LOCK
EL
PT
6 Pin
AP10
DC 12V
AP10
DC 12V
ADAPTER
6 Pin
C. SOCA SL100
SL100 EXIT PUSH BUTTON
6 Pin
AP10
DC 12V
AD APTER
Note: (1)failsecure type lock : Connect to 6pin connector,purple and green points. (2)failsafe type lock : Connect to 6pin connector, purple and blue points. (3)exit push button can only be used by dry contact 12
RED
AP10
D C 12V
ADAPTER
P S
GREEN
+ +
GREEN
ADAPTER
AP10
DC 12V
ADAPTER
AP10
DC 12V
AD APTER
6 Pin
8 Pin
RE ED ( N.C) CO M N.C
N. C N. O
COM
+
SI RE N
+
AP10
DC 12V
6 Pin
8 Pin
N.C N.O
COM
+
SI REN
+
AP1 0
DC 1 2V
Note : (1) Proximity reader provides two external relay connecting points which are : A. Antidamage ( tamper switch and door sensor ) alarm output connecting point ( 8P orange connecting point ). B. Duress alarm output connecting point ( 8P yellow connecting point ). 13
(2) If door sensor detecting (such as reed switch) points are applied, please set ALARM to ON mode. For setting method, please refer to setting mode functional selection item 7 in the manual. 3. For installation, please link power supply wire and control wire through the base panel first and then fix the base panel onto the wall. 4. Install the proximity reader on the base panel (power supply wire and control wire must first be inserted and the wires must be arranged correctly), and then use the enclosed key wrench and screws to mount it up. 5. Power supply: DC 12V 500~800mA. 6. Power consumption, standby 90mA, active 110mA. 7. Dimensions: 125mm (L) X 33mm (W) X 70mm (H).
DO NOT SHARE THE SAME POWER SUPPLY OF BOTH ELECTRIC LOCK AND PROXIMITY READER TOGETHER. USERS SHOULD PROVIDE SEPARATE POWER SUPPLY FOR BOTH OF THEM.
PRECAUTIONS :
1. Before installation, please check the voltage and polarity of the power supply in order to avoid wrong connection causing damage to the reader. 2. Please do not share the power supply together with the electric lock and the proximity reader . 3. Please do not install metal product or monitor near this equipment in order to avoid distance proximity. 4. Please do not conduct any fixing or modification to the system, unless by qualified personnel. 5. Warranty period for the reader is 1 year.
14
TROUBLESHOOTING
1. Card sensed but the door lock doesn't work. Solution: (1) Please check if the power supply is on the proximity reader and the electric lock. (2) If (1) is checked, please check the electric lock power supply and whether the connecting points are correct. (3) Continuous proximity. Please remove the card from the reader and try again. (4) Please check whether the door opening mode is correct. 2. System password is entered but cannot enter into various functional selection of the setting mode. Solution : (1)Incomplete input of system password, please check whether the following format has been entered: #XXXX# (XXXX represents system password), or first press "" then enter valid system password #XXXX#. (2)Bad wiring. Please arrange and put all power and control wires at a space behind the panel (recommended) to avoid pressing against the PC board which may cause short circuit or poor connection. 3. How to use the duress code setting? Solution : (1) Users should change door opening mode to 4digit password door opening(mode code 1), or proximity card or 4digit password door opening(mode code 4) in order to enable duress code setting. (2) After the door opening mode is set(please refer to item 5 of the setting mode functional selection on how to set door opening mode),press"The Duress code+4digits door opening password",then the duress alarm output function will execute. 4. How to terminate antidamage activation or duress alarm activity? Solution : Enter into system setting mode or open the door. 5. What is the operation of the door sensor detection (reed switch)? Solution : If the door sensor detection function is being set at ON (for detail, refer to item 7 of the setting mode functional selection in the manual) and if the door is not closed within 30 seconds, then the antidamage output function will be activated. 15
STEP2: Use enclosed special L shape spanner to unscrew and remove the special acrews anticlockwise (direction).Please make sure all four Orings are fitted to the screws,when removed.
STEP3:
16
STEP4:
Screw water proof pad with base cover tightly onto the wall.
STEP5: Link connectors through water proof pad and base cover to connect to the reader unit.
STEP6:
Screw the front cover with base cover tightly with four screws(make sure all four Orings are fitted to the screws)
17
STEP4:
Attention:(When mounting onto rough wall) Use appropriate size of flat acrylic or wood piece(Do not use metal piece) to mount onto rough wall with silicon glue.Screw or fit the base cover onto it.
silicon glue
18