Datatool Alarm Manual
Datatool Alarm Manual
Welcome
Thank you for choosing the new Datatool S4 Alarm system for your motorcycle. The system provides many unique features designed to increase the protection of your machine or to customise its operation to meet your individual requirements. Some of these features can only be adjusted by your dealer and are dependent on local regulations. For these reasons, we advise you to discuss the options available with your installing dealer. We also advise you read this manual carefully and keep it safe for future reference. This manual covers the following products: Datatool S4 Red, Alarm/Immobiliser system (insurance approved for all motorcycles) Datatool S4 Green, Alarm Upgrade system (insurance approved for machines already complying with Thatcham category 2 immobilisation. Visit www.thatcham.org for the latest listings). Datatool S4 Yellow, Alarm/Immobiliser system (insurance approved for machines up to 125ccs) Please be aware that insurance companies may on occasion apply other requirements regarding the cover of machines.
S4 Red/Green standard
S4 Yellow
Model S4 Yellow
The S4 Yellow transmitter contains a single CR2032 Lithium battery. This battery will normally last at least 24 months. (See S4 Red and Green for range and its reduction with age). 1. Use a small coin, placed in the recess between the two case halves near the key attachment hole, to split the casings. 2. Lift the circuit board from the rubberised seal. 3. Remove the CR2032 Lithium battery from its holder noting the polarity. 4. Maintaining the polarity, fit a new battery into the holder and then refit the circuit board into its rubberised housing. 5. Line up the two case halves and snap them together 6. Finally test the remote control for correct operation by operating the alarm. NOTE: For the safe use and disposal of batteries, please refer to the relevant section at the end of this manual. If you are unsure or have trouble in replacing/ sourcing a battery your Datatool dealer will be able to assist you.
Press to arm
2 flashes, LED flashes 5 seconds after arming. System is fully armed after 20 seconds.
Press to disarm
Flash once, LED flash according to number of remote coded to the alarm
Press to arm
2 flashes
3 flashes
Automatic re-arming
To ensure the machine remains covered at the level chosen the last time you armed it, when the system is disarmed it automatically starts a 45 second countdown after which the system will automatically re-arm at the SAME level as it was last armed in (i.e. passive immobiliser, full alarm or full alarm minus movement sensors). If the ignition is turned or one of the trigger switches is operated (e.g. seat removed if the switch is fitted to it) within the 45 second countdown period, the unit will passively immobilise. NOTE: If full passive arming has been selected and the ignition is turned ON/OFF the alarm will re-arm fully. If one of the trigger switches has been operated the alarm will only immobilise.
2 3
Silent arming/disarming
If you have asked your dealer to select the arm/disarm tones you can still arm or disarm the system without the tones on a one-off basis. To arm/disarm silently, simply press the BLACK button of the remote control followed by the GREY button. The system will arm or disarm for this one operation and only flash the indicators. NOTE: The inclusion of the arm and disarm indication beeps is strictly forbidden in all EU countries.
4 5 6 7
NOTE: The S4 Yellow product uses the shock sensor for movement detection and is equipped with only the potential for trigger switch 1 and no trigger switch 2. Therefore diagnostic 3 and 6 are not contained within the code sequence for this product. All S4 Alarm systems store the last five triggers within their memory. This can only be accessed by an approved Datatool Installer to assist them in servicing your system. 8
Press BLACK Press GREY Flashes only
Sleep mode
All alarm systems use a small amount of current during operation and we advise if the machine is to be left for an extended period in the armed state, it is left connected to a float charger suitable for maintaining the condition of the battery without damaging it, such as the Datatool Battery Conditioner (Pt No. 02012011). However the Datatool S4 systems include a three level sleep procedure to reduce the current consumption of the system as the motorcycle battery starts to discharge. This system reduces the risk of damaging the machines battery through being left in a discharged state. The levels of sleep are as follows:
Panic/locator feature
Press and hold the BLACK button of the remote for 3 seconds with the ignition switched OFF to enter panic/locator mode. The siren will sound and the indicators will flash until any button is pressed on the remote control to turn the panic/locator mode off. When triggered, the alarm system reverts to the original state held before the button was pressed to activate the panic/locate mode.
Ignition ON
Press GREY button One flash, one beep
Ignition OFF
one beep Press both buttons for 10 seconds
Winter mode
The purpose of this mode is to enable you to leave the machine for long periods of time with the alarm drawing an absolute minimum current (250A) from the machines battery. In this mode the alarm system is no longer active and it leaves the machine immobilised only. Should you decide to place the machine in this state, we strongly advise you to use further measures to protect your machine with quality physical security such as the Thatcham approved Datatool Python Lock and Chain system combined with a Datatool Fortress Ground Anchor. NOTE: The machines battery will still naturally discharge over time so we advise you to check its condition periodically.
10
11
Ignition ON
Press GREY button
Ignition OFF
Ignition OFF
Ignition ON
LED on bike flashes rapidly for 3 seconds
four beeps & flash two beeps & flash six beeps & flash
New PIN
3. If you do not set a PIN you will not be able to disarm the system should you lose or damage your remote control. 4. The PIN is also required to add further remote controls or change the operation of the alarm via the software switches. 5. Should you require your dealer to change any settings or add a new remote control you should inform them of your PIN. They will still be able to carry out customisation of the unit but they will have to over-write your existing PIN and you will have to re-enter your preferred number.
The procedure is as follows: 1. Turn the ignition ON to initiate an alarm reaction, (this will be immediate if the alarm is armed, or after 10 seconds if the immobiliser only is armed). 2. The alarm will sound for 30 seconds and the indicators will flash for 30 seconds. Do not turn the ignition OFF during the sounding phase. 3. When the alarm reaction stops, the motorcycle LED will be on constantly for 5 seconds. During this 5 second period, turn the ignition OFF and ON. 4. The override procedure will start immediately, indicated by rapid flashes of the LED for 3 seconds which then switch to a slow flash combined with beeps as detailed within the PIN entry section above. 5. Count the number of slow flashes from the LED or beeps from the siren until it equals the first digit of the PIN code and then turn the ignition OFF and ON. Again if you have selected zero as your first PIN number you must turn the ignition OFF and ON immediately after the rapid flashes stop. 6. The system will then return to the rapid LED flash sequence for 3 seconds and then go to slow flashes/beeps. Count the number of flashes or beeps from the siren until it equals the second digit of the PIN code and then turn the ignition OFF and ON. 7. Repeat the sequence to enter the 3rd and 4th PIN numbers.
YOU NOW HAVE 45 SECONDS TO TURN THE IGNITION ON AND START THE MOTORCYCLE
Until your transmitter is replaced or repaired, this procedure must be repeated to disarm the system every time it arms. Entering an incorrect PIN will initiate a full alarm reaction.
13
14
Default setting
Listen for the correct number of beeps and press both buttons to enter the software switch 1 Change siren tone (eight tones available) Siren 1 Sequential GREY button = Next tone BLACK button = Previous tone BOTH Buttons = Accept tone GREY button/LED ON = Full passive alarm BLACK button/LED OFF = Passive immobiliser BOTH buttons = Accept arming method Operable by installation engineer only
Full passive arming alarm/ passive immobiliser selection Select engineer software switches
Off
2. Each press of the GREY button will move the siren tone forward to the next. If you press the BLACK button you will return to the previous tone. 3. Once you have decided the siren tone you require press both buttons of the remote control. When you have selected it a double beep will be heard and you will return to the software switch selection.
15
Changing the passive arming settings (passive immobiliser or full passive arming)
1. Once you have found the passive arming selection (Switch 2), press BOTH buttons of the remote control to select the switch. A triple beep will be heard confirming you have entered the switch. 2. The factory default setting for this switch is OFF. If you wish to turn it ON (full passive arming of the alarm and immobiliser) press the GREY button of the remote control and the system LED will be lit confirming you have selected full passive arming. If you wish to return to passive immobiliser only, press the BLACK button of the remote control and the LED will be OFF to confirm the setting.
3. Once you have set the alarm to your arming preference, press BOTH buttons of the remote control to confirm the setting, a double beep will be heard and you will return to the software switch selection. To exit software switch selection simply turn the ignition OFF completely.
Ignition ON
Disconnect battery
Ignition OFF
16
2 3 4 5 6 7 8
Return software switches to default System diagnostics with event memory Movement sensor adjustment (S4 Red and S4 Green only) Shock sensor adjustment Arm / Disarm Tones Panic Nudge sensor (S4 Red and S4 Green)
8a
17
Covering accessories
The alarm system has a secondary trigger input, which in certain instances may be able to be connected to the side stand or to be used to offer some protection to detachable luggage etc, by looping an extension cable through it. This is not part of the standard installation so please discuss this with your dealer.
Garage security
Your alarm system can be extended to give protection to your garage whilst the machine is parked within it. There are two methods available, a remote linked passive infra-red detector system and a hard-wired magnetic contact system.
Declaration of conformity
The declaration of conformity certificates applicable to the Datatool S4 range of security systems can be viewed at www.datatool.co.uk/product
Contacts
For further information please contact Datatool (UK) Ltd by e-mail at [email protected] Our website www.datatool.co.uk contains full UK dealer listings along with links/contact details for all international distributors. It also contains information covering the rest of our product range of rider safety security and information products along with useful hints and tips regarding securing your machine.
19
Panic/Locator
With the system armed, press and hold BLACK button until the alarm sounds. To silence, press either button on the remote control
Immobilise only
Ignition OFF for more than 45 seconds
Alarm fully
Press GREY button within 45 seconds of ignition OFF
Hazards
Press GREY and BLACK buttons together until the hazards start to flash. To turn off press BOTH buttons again
Ferry Mode
Press BLACK button within 10 seconds of arming the alarm fully
For full instructions on features please refer to the main manual or visit www.datatool.co.uk